• 제목/요약/키워드: Jecheon Fire

검색결과 23건 처리시간 0.03초

제천스포츠센터의 수직 화재확산 해석을 위한 화재시뮬레이션 분석에 관한 연구 (A Study on the Fire Simulation for Vertical Fire Diffusion Analysis of Jecheon Sports Center)

  • 최윤주;김윤성;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2022
  • In December 2017, a fire at the Jecheon Sports Center caused 29 deaths and 40 injuries, and about 2 billion won in property damage. It is a facility used by unspecified people as a publicly used establishment with a piloti structure. The damage was expanded due to the ignition of combustible exterior materials, Lack of fire protection in horizontal and vertical penetrations. Although legislation has improved since the fire, it is not retroactively applied, increasing the risk of fire in existing buildings. Accordingly, it is necessary to examine the case of the Jecheon Sports Center fire and draw out the problems. In this study, the fire simulation results and the Jecheon Sports Center fire are comparatively analyzed and used as basic data for fire reduction measures in publicly used establishment. As a result of the fire simulation drive, in the case of the second floor, the room temperature exceeded the human life safety standard of 60 ℃ after about 700 seconds had passed. In the case of three floor, it is predicted that the indoor temperature will exceed about 350 ℃. and temporary complexation will occur in the indoor combustibles.

  • PDF

제천 스포츠복합건물 화재 재난에서의 권역재난의료지원팀 활동 경험 고찰: 한계점과 구조의 중요성 (Experience of a Disaster Medical Assistant Team activation in the fire disaster at Jecheon sports complex building: limitation and importance of rescue)

  • 정승교;김윤섭;김오현;이강현;김관래;정우진
    • 대한응급의학회지
    • /
    • 제29권6호
    • /
    • pp.585-594
    • /
    • 2018
  • Objective: This study was designed to report on the progress of the fire at Jecheon sports complex and to assess the adequacy of Disaster Medical Assistant Team (DMAT)'s activities in response to the fire disaster. Methods: We conducted a retrospective review based on camera recordings and medical records that were recorded at the disaster site for assessment of activities. We cooperated with firefighters, police officers, local hospital medical staffs and public health personnel in Jecheon in order to classify patients in the disaster field and to understand the patients' progress. Results: At 15:53, the first request for emergency rescue came to the 119 general emergency call center, and a request for DMAT activation came at 16:28. DMAT arrived at the site at 17:04 and remained active until the following day at 00:43. The total number of casualties was 60, including 27 minimal (Green) patients, 29 expectant (Black) patients, three delayed (Yellow) patients, and one immediate (Red) patient. There were 32 patients who received on-site care by DMAT. Two patients were transferred from a local hospital to Wonju Severance Christian Hospital for hyperbaric oxygen therapy. Conclusion: Twenty-nine victims were found in the sports complex building, and there were 31 mildly to moderately injured patients in this fire disaster. The main cause of death was thought to be smoke suffocation. Although DMAT was activated relatively quickly, it was not able to provide effective activity due to the late rescue and difficulty with fire suppression.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 - (Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.86-94
    • /
    • 2018
  • 제천 스포츠센터 화재로 29명이 사망하고 40명이 부상을 입었다. 이 논문에서는 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 요인을 분석하기 위해 저자의 화재조사 결과를 토대로 건물과 설비의 구조적인 요인을 분석하고 있다. 건물과 설비의 구조적인 요인은 필로티 구조의 주차장, 필로티 주차장과 로비 사이 방화구획 미비, 필로티 주차장에 스프링클러설비 미설치, 1층 주계단에 방화문 미설치, 옥상에 소화수조 미설치, 2층 주출입구에 벽체 매립형 방화문 설치, EPS실 및 배관 피트 층별 방화구획 부실, 배수배관 연결부의 누수, 화물용 승강기의 승강로와 실내에 면하는 벽체에 합판 설치, 폐쇄형 옥상구조로 개조, 주차장 반자 안쪽 천장에 스티로폼 단열재 부착, 2층 여탕 무창층 강화유리 구조, 드라이비트 외벽으로 분석하였다.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로- (Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.57-66
    • /
    • 2018
  • 29명이 사망하고 40명이 부상을 입은 제천 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 원인을 초기대응과 관리적인 측면을 중심으로 분석하였다. 초기대응 측면은 119신고 지연, 2층 세신사 비상구로 피난유도를 하지 않음, 1층과 3층 비상계단쪽 방화문 개방 상태 유지, 3층 주계단실 쪽 방화문 닫지 않음, 비상방송을 하지 않음으로 분석하였다. 관리적인 측면은 1층의 스프링클러설비 알람밸브 폐쇄, 소방펌프 제어반에서 기동 정지 위치에 놓음, 주차장 반자 안 누수 및 누전 방치, 2층 여탕의 휴게실 피난구유도등이 가려져 있고 비상구에 물건이 적치됨, 2층 자동문의 조작버튼 불량상태로 방치, 형식적인 소방안전관리, 소방시설 부실한 자체점검, 방화셔터와 배연창 미작동으로 분석하였다.

Application of the Maryblyt Model for the Infection of Fire Blight on Apple Trees at Chungju, Jecheon, and Eumsung during 2015-2020

  • Ahn, Mun-Il;Yun, Sung Chul
    • The Plant Pathology Journal
    • /
    • 제37권6호
    • /
    • pp.543-554
    • /
    • 2021
  • To preventively control fire blight in apple trees and determine policies regarding field monitoring, the Maryblyt ver. 7.1 model (MARYBLYT) was evaluated in the cities of Chungju, Jecheon, and Eumseong in Korea from 2015 to 2020. The number of blossom infection alerts was the highest in 2020 and the lowest in 2017 and 2018. And the common feature of MARYBLYT blossom infection risks during the flowering period was that the time of BIR-High or BIR-Infection alerts was the same regardless of location. The flowering periods of the trees required to operate the model varied according to the year and geographic location. The model predicts the risk of "Infection" during the flowering periods, and recommends the appropriate times to control blossom infection. In 2020, when flower blight was severe, the difference between the expected date of blossom blight symptoms presented by MARYBLYT and the date of actual symptom detection was only 1-3 days, implying that MARYBLYT is highly accurate. As the model was originally developed based on data obtained from the eastern region of the United States, which has a climate similar to that of Korea, this model can be used in Korea. To improve field utilization, however, the entire flowering period of multiple apple varieties needs to be considered when the model is applied. MARYBLYT is believed to be a useful tool for determining when to control and monitor apple cultivation areas that suffer from serious fire blight problems.

필로티건축물의 화재확산방지를 위한 시범시공 (Trial Construction for the Prevention of Fire Spread in Piloti Building)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

한·일 건축물 방화구획 기준 비교분석 (A Comparative Analysis on the building Fire Protection Standards of Korea and Japan)

  • 신영덕;한지우;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2019
  • Smoke and fire spread throughout the building as a result of problems in the fire prevention section of Uijeongbu Apartment Fire in 2015 and Jecheon Sports Center Fire in 2017 in Korea, causing a number of casualties. It is believed that the fire compartment standards need to be reviewed as the fire in recent buildings continues to show problems. In this study, a comparative analysis was conducted on the fire prevention zone standard with Japan to improve the fire compartmente standard in Korea.

  • PDF

가연성 외장재를 사용한 건축물의 화재확대방지에 관한 연구 (A Study on Fire Spread Prevention of Building using Combusitible Exterior)

  • 박성하;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2018
  • Recently, a large fire has occurred through a dry bit, which is a flammable exterior material, in Daebong Green Apartment Fire in Uijeongbu in 2015 and Jecheon Sports Center Fire in 2017. In this study, KS F ISO 5660-1 Cone calorimeter experiment was used to examine the fire risk of dry bit. Also, the performance of the repair and reinforcement materials to prevent fire expansion was examined. As a result, the dry bit is likely to be ignited by internal and external flower gardens, and its combustion rate and calorific value are very high. In addition, the performance of heat resistance such as ALC panel and ceramic board as a repair and reinforcement material has been proved. However, the insulation is expected to require further consideration.

  • PDF

건축물 화재시 필요내화 시간 산정 및 간이식 도출 (Calculation of Fire-resisting Time and Extraction of Simple Transplants in the Event of a Building Fire)

  • 김윤성;한지우;김혜원;진승현;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2020
  • Large fires continue to spread throughout the building, including the fire in Uijeongbu in 2015, the fire in Jecheon in 2017, and the fire in Miryang in 2018. According to the above fire case investigation, major problems were the fire resistance performance of compartment members such as fire doors, the fire spread due to damage to exterior wall openings, and smoke spread through vertical openings. However, in South Korea, only specification design is implemented for buildings that are not subject to performance design. In addition, the analysis of the fire resistance performance standards of building members in the specification design showed that fire doors were not specified in detail for 60 minutes of insulation performance and 60 minutes of fire resistance performance of E/V doors, limiting the prevention of fire spread. Therefore, the purpose of this research is to prepare measures to prevent the spread of fire by presenting simple transplants for calculating the required fire time according to the architectural design conditions for the performance design of the components of the fire room according to the purpose of use of the front of the building.

  • PDF

급성관상동맥증후군 환자의 병원 전 119구급의료서비스 실태 및 개선방안 -충북 제천.단양을 중심으로- (A Survey on Prehospital Emergency Medical Service for the Improvement of Acute Coronary Syndrome Assessments - Focus on the Jecheon.Danyans Area -)

  • 노상균
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.293-299
    • /
    • 2008
  • 119 구급대를 이용하여 급성관상동맥증후군을 진단 받은 97명의 환자평가로는 혈압 27.8%, 호흡 23.7%, 맥박 33.0%를 측정하였고, 응급처치로는 산소공급 52.6%, 안정 12.4%, 심전도 체크 4.1%, Nitroglycerin(NTG) Aspirin 정맥로 확보 둥은 0%로 전체적인 수행율이 낮게 확인되어 급성관상동맥증후군 환자의 병원 전 처치가 제대로 이루어지지 못하고 있다. 따라서 구급대인의 질적 향상을 위해서 실무중심의 지속적인 교육, 교육 후에는 반드시 평가를 병행하여 적정수준 미달자에게는 재교육을 받도록 하는 등 구급대원의 자질을 강화시킬 수 있도록 내부적인 초안이 마련되어야 할 것이다.