• 제목/요약/키워드: J-test

검색결과 5,301건 처리시간 0.041초

실내 가속부식시험을 통한 해양 강관합성 말뚝의 방식 기법 수명 평가 (Evaluation of Life Time for Anti-Corrosive Methods for Marine Steel Sheet by Cyclic Corrosion Test)

  • 박종원;이종구;이경황;김진홍;정문경;이주형
    • Corrosion Science and Technology
    • /
    • 제8권6호
    • /
    • pp.243-250
    • /
    • 2009
  • When a steel sheet pipe applied to marine environment, an anti-corrosive coating should be treated to obtain long-term life-time for steels, especially, splash zone. Although anti-corrosive property of coatings is required to be tested in real marine environment, it is difficult because of long test time such as 20 years or more time. Therefore, we used cyclic corrosion tester in a laboratory, which has similar conditions with salt-dry-wet process such as real marine environment. Anti-corrosive properties of the coatings and two steels were tested their anti-corrosive properties under cyclic corrosion test conditions(KS D ISO 14993) and the results were compared with estimate life-time in real marine environment. According to cyclic corrosion test, accelerated corrosive factor of each anti-corrosive coating was investigated accelerated corrosive factor from impedance with EIS method. Accelerated corrosive factor of type SS400 carbon steel and A690 was also investigated their accelerated corrosive factor from the regression curves of weigh loss results. One of the anti-corrosive coatings showed about 50 years life-time compared with standard sample life-time. Carbon steel SS400 showed from 0.1 mm/yr to 0.06 mm/yr as its corrosion rate.

탄소섬유 강화 복합재로 구성된 인라인 디스크 휠의 충격거동 평가 (Evaluation of the Impact Behavior of Inline Disk Wheel Made of Carbon Fiber Reinforced Composites)

  • 권혜인;이상진;신광복
    • Composites Research
    • /
    • 제29권2호
    • /
    • pp.73-78
    • /
    • 2016
  • 본 연구에서 다루는 탄소섬유 복합재 인라인 휠은 플라스틱 인라인 휠 허브의 기존 재질을 탄소섬유 직물/에폭시 수지로 구성된 디스크 형의 허브로 대체하는 것이다. 지면으로부터의 충격 하중은 탄소섬유 복합재 휠의 충격 성능 평가를 위해 저속 충격 시험이 수행되었고, 기존의 플라스틱 휠의 성능과 비교하여 수행되었다. 본 연구는 시험 조건으로 70 J의 충격 하중을 적용하였다. 충격 에너지는 타격 추의 높이와 무게를 조정하여 조절되었다. 탄소섬유 복합재 디스크 허브의 사용은 무게를 절감하고 실제 운행 조건과 유사한 조건인 낮은 충격에너지에서 우수한 반발력을 나타내는 것으로 확인되었다. 충격 하중에 따라 최대 하중은 비례적으로 증가하지만, 최대 하중의 성장은 20 J 충격 하중에서 감소되었고, 45 J 충격 하중에서부터 감소되는 경향의 결과를 보였다. 탄소섬유 복합재 휠은 5 J, 10 J의 충격 하중에서 전체 충격 에너지의 35.3, 19.1%가 리바운딩 되는 우수한 특성을 보였다. 반면에 20 J 이상의 충격하중에 대해서는 얇은 탄소섬유 복합재 허브의 크랙 생성으로 인해 전체 에너지의 5% 이하로 리바운드 되었다.

일반 구조용강 열간압연 박판에 대한 CTOD와 CTOA 곡선 결정 (Determination of CTOD & CTOA Curve for Structural Steel Hot-Rolled Thin Plates)

  • 이계승;이억섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.729-732
    • /
    • 2003
  • The K-R design curve is an engineering method of linear-elastic fracture analysis under plane-stress loading conditions. By the way, linear-elastic fracture mechanics (LEFM) is valid only as long as nonlinear material deformation is confined to a small region surrounding the crack tip. Like general steels, it is virtually impossible to characterize the fracture behavior with LEFM, in many materials. Critical values of J contour integral or crack tip opening displacement (CTOD) give nearly size independent measures of fracture toughness, even for relatively large amounts of crack tip plasticity. Furthermore, the crack tip opening displacement is the only parameter that can be directly measured in the fracture test. On the other. the crack tip opening angle (CTOA) test is similar to CTOD experimentally. Moreover, the test is easier to measure the fracture toughness than other method. The shape of the CTOA curve depends on material fracture behavior and, on the opening configuration of the cracked structure. CTOA parameter describes crack tip conditions in elastic-plastic materials, and it can be used as a fracture criterion effectively. In this paper, CTOA test is performed for steel JS-SS400 hot-rolled thin plates under plane-stress loading conditions. Special experimental apparatuses are used to prevent specimens from buckling and to measure crack tip opening angle for thin compact tension (CT) specimens.

  • PDF

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.

STUDIES ON THE IN VITRO SPF TEST METHOD OF SUNSCREEN PRODUCTS

  • K. H. Son;Kim, Y. O.;Lee, J. P.;S. J. Yang;Kim, W. H.;Kim, C. K.;M. Y. Heo;S. J. Jang;Park, S. S.
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.528-528
    • /
    • 2003
  • The present study was undertaken to develop the in vitro sun protection factor(SPF) test method having good correlation with in vivo method using human. 8% homomentyl salicylate, P3 reference standard and commercially available sunscreen products were measured by the in vitro method using SPF 290S analyzer, and the SPFs were compared with the SPFs measured by in vivo test method. In vitro SPFs of 8% HMS and P3 reference standard were 4.59 $\pm$ 0.12 and 14.94 $\pm$ 0.83. There are good correspondence, correlation coefficients were 0.9506 and 0.9769 respectively, between the in vitro and in vivo SPFs for the sunscreen creams and lotions. Correlation coefficients of makeup base/liquid foundation, lotion labled with "shake before use" and compact powder were 0.8812, 0.8632 and 0.5984 respectively. The optimum mixture ratio of compact powder and cream base represents 1:0.8. These results suggest that the in vitro SPF test method will be able to be used as an alternative method for in vivo SPF in case of lotion and cream.

  • PDF

보이스코일형 LOA의 진동능동제어 시스템에의 응용에 관한 연구 (A Study on the Application for the Vibration Active Control by using a Voice call type LOA)

  • 장석명;정상섭;서진호;김형규;박희창;문석준;정종안;박찬일;정태영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.317-319
    • /
    • 1996
  • In this paper, an active vibration control system using a voice coil type linear oscillating actuator(LOA) is studied to suppress structural vibration. Being compared with a hydraulic actuator, a LOA has simplified structure and requires a few elements in the driving system, so it has lots of merits with respect to economics and maintenance. The general mathematical dynamic model to obtain the algorithm for the realization of vibration active control system is treated. Actually, the performance test of the control system using LOA is carried out on a steel test structure under sinusoidal and white noise excitation. From this test it is conformed that acceleration level of test structure is reduced near the resonance region. In the future research on the application to large structures will be studied.

  • PDF

등가부하법에 따른 유도기 온도상승 시험시 발생 증분 손실 해석 (Analysis on the increasing loss in Temperature rise test of induction motor by equivalent load method)

  • 박정태;이정일;김근웅;권중록;권병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1045-1046
    • /
    • 2007
  • As equivalent load method of induction motor, even without connecting load, for temperature rise test has been acknowledged economic and corrective method, the method has been widely used instead of the real load method, and also international standards IEC 61986 is published in 2002. ABB, an well-known and famous electric machinery maker in the world, has been already applying the equivalent load method since 2002. HHI has been using real load method and equivalent load method for temperature rise of induction motor, it is already known that the equivalent test results is higher as $1-5^{\circ}K$ than that of real load test. But, quantity analysis for the reason of the temperature rise is not satisfied sufficiently. So, in this paper, quality analysis and also quantity analysis was conducted.

  • PDF

UV-경화 폴리머 마이크로 구조물의 응력-변형률 관계 측정에 관한 연구 (A study on stress-strain relation measurement for micro scale UV-curable polymer structure)

  • 정수정;김재현;이학주;박상후;양동열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.492-497
    • /
    • 2005
  • In this study, we propose an advanced nanoindentaion test, Nano Pillar Compression Test (NPCT) to measure a stress-strain relation for micro scale polymer structures. Firstly, FEM analysis is performed to research behavior of micro polymer pillars in several specimen aspect ratios and different friction conditions between specimen and tip. Based on the FEM results, micro scale UV-curable polymer pillars are fabricated on a substrate by Nano Stereo Lithography (NSL). To measure their mechanical properties, uniaxial compression test is performed using nanoindentation apparatus with flat-ended diamond tip. In addition, the dependency of compression properties on loading condition and specimen size are discussed.

  • PDF

실배관 파괴특성 평가에 관한 연구 (A Study on the Evaluation of the Pipe Fracture Characteristic)

  • 박재실;김영진;석창성
    • 대한기계학회논문집A
    • /
    • 제29권1호
    • /
    • pp.107-114
    • /
    • 2005
  • In order to analyze the elastic-plastic fracture behavior of a structure, the fracture resistance curve of the material should be known first. The standard CT specimen was used to obtain the fracture resistance curves of a piping system. However, it is known that the fracture resistance curve by the standard CT specimen is very conservative to evaluate the integrity of a structure. Also the fracture resistance curve is effected by the specimen geometry and the dimensions because of the constraint effect. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the standard CT specimen and to provide an additional safety margin. For these, the fracture tests using a real pipe specimen and the standard CT specimen test were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method was used to measure the crack extension and the length for the pipe test. Also finite element analyses were performed with a CT specimen and a pipe in order to prove the additional safety margin. From the result of tests and analyses of the pipe and the standard CT specimen, it was observed that the fracture analysis with the standard CT specimen is conservative and the additional safety margin was proved.