• Title/Summary/Keyword: J-scaling

Search Result 157, Processing Time 0.027 seconds

Acoustic Echo Cancellation using the DUET Algorithm and Scaling Factor Estimation (잡음 상황에서 DUET 블라인드 신호 분리 알고리즘과 스케일 계수 추정을 이용한 음향 반향신호 제거)

  • Kim, K.J.;Seo, J.B.;Nam, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.416-418
    • /
    • 2006
  • In this paper, a new acoustic echo cancellation approach based on the DUET algorithm and scaling factor estimation is proposed to solve the scaling ambiguity in case of blind separation based acoustic echo cancellation in a noisy environment. In hands-free full-duplex communication system. acoustic noises picked up by the microphone are mixed with echo signal. For this reason, the echo cancellation system may provide poor performance. For that purpose, a degenerate unmixing estimation technique, adjusted in the time-frequency domain, is employed to separate undesired echo signals and noises. Also, since scaling and permutation ambiguities have not been solved in the blind source separation algorithm, kurtosis for the desired signal selection and a scaling factor estimation algorithm are utilized in this rarer for the separation of an echo signal. Simulation results demonstrate that the proposed approach yields better echo cancellation and noise reduction performances, compared with conventional methods.

  • PDF

Scaling Analysis of Thermal Hydraulics Phenomena in the Nuclear Reactor Vessel Downcomer during the Reflood Phase of LBLOCA (대형냉각재 상실사고 재관수 기간 동안, 차세대 원자로 강수부 내의 열수력 현상 모의를 위한 실험장치 척도해석)

  • Yun, B.J.;Song, C.H.;Kwon, T.S.;Euh, D.J.;Chu, I.C.;Yoon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.821-827
    • /
    • 2001
  • As one of the advanced design features of the Korea next generation reactor, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLl) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood period of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, a new scaling method, using time and velocity reduced linear scaling law, is suggested for the design of a scaled-down experimental facility to investigate the direct ECC bypass phenomena in PWR downcomer.

  • PDF

Oral health attitudes and behaviors among clients receiving scaling (치면세마실습실 방문자의 스켈링 행태에 관한 분석)

  • Kang, Yong-Ju;Jang, Gye-Won;Jeong, Mi-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.5
    • /
    • pp.773-782
    • /
    • 2011
  • Objectives : The purpose of the study was to investigate self-reported oral health attitudes and behaviors among patients receiving scaling services and provide guidelines for developing preventive programs for dental disease. Methods : The survey was administered to a sample of 462 receiving voluntary scaling service in the practice lab in the department of dental hygiene at J health college. Results : 1. Of all participants, 261(56.5%) reported that they received scaling services in the past. 134 of the women (62.6%) and 127 of the men (51.2%) received scaling services 2. Analysis of the regular scaling attendance rates showed that only 16.2% of all participants received routine scaling. 13.7% of the male participants and 19.2% of the female participants received scaling on a regular basis. 3. Participants commonly reported "self-motivation" and "suggestion by others" (37.9% and 34.1%, respectively) as the main reasons for obtaining scaling services. 4. The main reasons for not obtaining scaling services were "I did not know about scaling" (39.3%), "I don't feel it is necessary" (27.4%) and "because I am scared" (20.9%). More men (42.1%) than women (35%) reported that they did not know about scaling. 5. Of the total participants, 41.6% reported that they were concerned about oral health at a moderate level, and 30.3% reported that they were concerned about oral health at a high level. 6. Of the participants who responded "very concerned about oral health" and "extremely concerned about oral health", the majority obtained scaling service (70.2% and 84.2%, respectively). Conclusions : The study suggested that researchers and national health authorities should develop routine scaling, preventive dental care, and oral health programs for oral health promotion and disease prevention.

Scaling analysis of electrorheological poly(naphthalene quinone) radical suspensions

  • Min S. Cho;Park, Hyoung J.
    • Korea-Australia Rheology Journal
    • /
    • v.12 no.3_4
    • /
    • pp.151-155
    • /
    • 2000
  • A semiconducting poly(naphthalene quinone) radical (PNQR) was synthesized from Friedel-Craft acylation between naphthalene and phthalic anhydride and used as dispersing particles of a dry-base electrorheological (ER) material in silicone oil. Under an applied electric field (E), the dynamic yield stress (${\tau}_{dyn}$) of this ER fluid, obtained from a steady shear experiment with a controlled shear rate mode, was observed to increase with $E^{1.45}$ Based on this relationship, we propose a universal correlation curve for shear viscosity, which is independent of E using a scaling analysis.

  • PDF

Development of scaling approach based on experimental and CFD data for thermal stratification and mixing induced by steam injection through spargers

  • Xicheng Wang;Dmitry Grishchenko;Pavel Kudinov
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1052-1065
    • /
    • 2024
  • Advanced Pressurized Water Reactors (APWRs) and Boiling Water Reactors (BWRs) employ a suppression pool as a heat sink to prevent containment overpressure. Steam can be discharged into the pool through multi-hole spargers or blowdown pipes in both normal and accident conditions. Direct Contact Condensation (DCC) creates sources of momentum and heat. The competition between these two sources determines the development of thermal stratification or mixing of the pool. Thermal stratification is of safety concern as it reduces the cooling capability compared to a completely mixed pool condition. In this work we develop a scaling approach to prediction of the thermal stratification in a water pool induced by steam injection through spargers. Experimental data obtained from large-scale pool tests conducted in the PPOOLEX and PANDA facilities, as well as simulation results obtained using validated codes are used to develop the scaling. Two injection orientations, namely radial injection through multi-hole Sparger Head (SH) and vertical injection through Load Reduction Ring (LRR), are considered. We show that the erosion rate of the cold layer can be estimated using the Richardson number. In this work, scaling laws are proposed to estimate both the (i) transient erosion velocity and (ii) the stable position of the thermocline. These scaling laws are then implemented into a 1D model to simulate the thermal behavior of the pool during steam injection through the sparger.

Impact of geometrical parameters on SGEMP responses in cylinder model

  • Chen, Jian-Nan;Zhang, Jun-Jie
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3415-3421
    • /
    • 2022
  • This paper is aimed to find out the impact of the geometrical parameters, mainly the radius and the height of a cylinder, on the SGEMP response including the famous scaling law in the classical cylinder model using a homemade PIC code UNIPIC-3D. We computed the electric fields at the center and at the edge on the emission head face with different radii and heights under normal X-rays incidence. The results show that the electric field will increase with the radius but decrease with the height. We analyze the scaling law that links the electric field product and fluence product, and whereafter an irreconcilable contradiction raises when the radius is changeable, which limits the application range of the scaling law. Moreover, the field-height-radius relation is found and described by a combination of logarithmic and minus one-quarter numerical fitting law firstly. Particle and magnetic field distributions are used to explain all the behaviors of the fields reasonably. All the findings will assist the evaluation of SGEMP response in spacecraft protection.

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

A Study on Design of the Modified Fuzzy-Compensated PID Controller (개선된 퍼지보상 PID제어기 설계에 관한 연구)

  • Lee, H.J.;Kim, J.G.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.111-118
    • /
    • 1995
  • This paper presents the modified fuzzy-compensated PID(FCPID) control, which involves adding the compensator to an existing PID controller, to improve the performances of the systems. Compared to a conventional PID control and a fuzzy logic control(FLC), the proposed control scheme has superior performance. Experimental results of an actual implementation of the modified PC-based FCPID controller on the DC servo-motor demonstrate considerable improve- ment of the performance of the existing FCPID control by monitoring the scaling factor. They show faster responses and smaller overshoots than the conventional FCPID control scheme for the various reference inputs and the robustness to the loads.

  • PDF