• 제목/요약/키워드: Iterative reconstruction

검색결과 207건 처리시간 0.02초

전력밀도 스펙트럼을 이용한 반복적 영상 신호 복원 알고리즘 (Iterative Image Restoration Algorithm Using Power Spectral Density)

  • 임영석;이문호
    • 대한전자공학회논문지
    • /
    • 제24권4호
    • /
    • pp.713-718
    • /
    • 1987
  • In this paper, an iterative restoration algorithm from power spectral density with 1 bit sign information of real part of two dimensional Fourier transform of image corrupted by additive white Gaussian noise is proposed. This method is a modified version of image reconstruction algorithm from power spectral density. From the results of computer simulation with original 32 gray level imgae of 64x64 pixels, we can find that restorated image after each iteration converge to original image very fast, and SNR gain be at least 8[dB] after 10th iteration for corrupted image with additive white Gaussian noise.

  • PDF

불완전 투영군의 반복 수정 알고리즘 (An Iterative Correction algorithm of Incomplete Projections (ICAIP))

  • 최종수
    • 대한전자공학회논문지
    • /
    • 제21권2호
    • /
    • pp.1-7
    • /
    • 1984
  • 전산기 단층영상(C.T) 장치에서 발생되는 불완전 투영군으로부터 단층상을 재구성할 수 있게한 하나의 알고리즘이 제안되고 있다. 알고리즘은 실측의 불완전 투영군, 물휴의 윤곽 정보등으로 부터 재구성-투영 과정속에서 회복 수정의 단순 조작에 의해 이루어지고, 그 유효성이 전산기 모의실험을 통해 검증되고 있다.

  • PDF

Fast Solution of Linear Systems by Wavelet Transform

  • Park, Chang-Je;Cho, Nam-Zin
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.282-287
    • /
    • 1996
  • We. develop in this study a wavelet transform method to apply to the flux reconstruction problem in reactor analysis. When we reconstruct pinwise heterogeneous flux by iterative methods, a difficulty arises due to the near singularity of the matrix as the mesh size becomes finer. Here we suggest a wavelet transform to tower the spectral radius of the near singular matrix and thus to converge by a standard iterative scheme. We find that the spectral radios becomes smatter than one after the wavelet transform is performed on sample problems.

  • PDF

Dosimetric Effects of Low Dose 4D CT Using a Commercial Iterative Reconstruction on Dose Calculation in Radiation Treatment Planning: A Phantom Study

  • Kim, Hee Jung;Park, Sung Yong;Park, Young Hee;Chang, Ah Ram
    • 한국의학물리학회지:의학물리
    • /
    • 제28권1호
    • /
    • pp.27-32
    • /
    • 2017
  • We investigated the effect of a commercial iterative reconstruction technique (iDose, Philips) on the image quality and the dose calculation for the treatment plan. Using the electron density phantom, the 3D CT images with five different protocols (50, 100, 200, 350 and 400 mAs) were obtained. Additionally, the acquired data was reconstructed using the iDose with level 5. A lung phantom was used to acquire the 4D CT with the default protocol as a reference and the low dose (one third of the default protocol) 4D CT using the iDose for the spine and lung plans. When applying the iDose at the same mAs, the mean HU value was changed up to 85 HU. Although the 1 SD was increased with reducing the CT dose, it was decreased up to 4 HU due to the use of iDose. When using the low dose 4D CT with iDose, the dose change relative to the reference was less than 0.5% for the target and OARs in the spine plan. It was also less than 1.1% in the lung plan. Therefore, our results suggests that this dose reduction technique is applicable to the 4D CT image acquisition for the radiation treatment planning.

전기 임피던스 단층촬영법에서 수정된 반복 Landweber 방법을 이용한 영상 복원 (Image Reconstruction using Modified Iterative Landweber Method in Electrical Impedance Tomography)

  • 김봉석;김지훈;김신;김경연
    • 전자공학회논문지SC
    • /
    • 제49권4호
    • /
    • pp.36-44
    • /
    • 2012
  • 전기 임피던스 단층촬영법은 대상물의 경계면에 부착된 여러 개의 전극들을 통해 전류를 주입하고 이에 유기되는 전압을 측정한 후, 이를 바탕으로 대상물 내부의 도전율(또는 저항률) 분포를 영상으로 복원하는 비교적 새로운 영상복원 기법이다. 본 논문에서는, 대상물 내부의 저항률 분포를 추정하기 위해서 전극사이의 전기저항과 저항률 분포와의 관계를 선형으로 가정하고, 이 선형 관계로부터 가중행렬을 계산한 후, 수정된 반복 Landweber 알고리즘을 적용하였다. 그리고 제안한 방법의 수렴시간을 줄이고 영상 복원의 정확도를 향상시키고자 목적 함수를 최소화하는 최적의 step length를 찾아 제안한 방법에 적용하였다. 몇 가지 시나리오를 설정하고 모의실험을 통해 제안된 방법의 영상 복원 성능을 평가한 결과, 비교적 양호한 복원 성능을 나타내었다.

CT를 이용한 지방측정에 ADMIRE 알고리즘이 미치는 영향 (Effects of ADMIRE Algorithms on Fat Measurements Using Computed Tomography (CT))

  • 이창욱;이상헌;임인철;이효영
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.465-472
    • /
    • 2019
  • 본 연구는 CT를 이용한 지방측정(Fat measurement)에 반복 재구성법(IR)이 어떠한 영향을 미치는지 알아보기 위하여 기존의 필터보정 역투영법(FBP)과 비교하여 고급 모델링 반복 재구성법(ADMIRE)은 어떠한 차이가 있는지 알아보고자 한다. CT Fat measurement에 ADMIRE가 미치는 영향에 대해 알아본 결과 기존의 Filtered back projection과 비교하여 Visceral fat area, Subcutaneous fat area, V/S Ratio, Visceral fat area의 HU 그리고 Subcutaneous fat area의 HU는 통계적으로 유의한 차이가 없었다. 하지만 ADMIRE Strength가 커질수록 Visceral fat area의 Noise는 최대 12%, Subcutaneous fat area의 Noise는 최대 19% 감소하였다. 그리고 CT를 이용한 Fat measurement에서 내장지방과 피하지방 측정에 ADMIRE 알고리즘은 아무런 영향을 주지 않았다.

Estimation of Noise Level and Edge Preservation for Computed Tomography Images: Comparisons in Iterative Reconstruction

  • Kim, Sihwan;Ahn, Chulkyun;Jeong, Woo Kyoung;Kim, Jong Hyo;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.92-98
    • /
    • 2021
  • Purpose: This study automatically discriminates homogeneous and structure edge regions on computed tomography (CT) images, and it evaluates the noise level and edge preservation ratio (EPR) according to the different types of iterative reconstruction (IR). Methods: The dataset consisted of CT scans of 10 patients reconstructed with filtered back projection (FBP), statistical IR (iDose4), and iterative model-based reconstruction (IMR). Using the 10th and 85th percentiles of the structure coherence feature, homogeneous and structure edge regions were localized. The noise level was estimated using the averages of the standard deviations for five regions of interests (ROIs), and the EPR was calculated as the ratio of standard deviations between homogeneous and structural edge regions on subtraction CT between the FBP and IR. Results: The noise levels were 20.86±1.77 Hounsfield unit (HU), 13.50±1.14 HU, and 7.70±0.46 HU for FBP, iDose4, and IMR, respectively, which indicates that iDose4 and IMR could achieve noise reductions of approximately 35.17% and 62.97%, respectively. The EPR had values of 1.14±0.48 and 1.22±0.51 for iDose4 and IMR, respectively. Conclusions: The iDose4 and IMR algorithms can effectively reduce noise levels while maintaining the anatomical structure. This study suggested automated evaluation measurements of noise levels and EPRs, which are important aspects in CT image quality with patients' cases of FBP, iDose4, and IMR. We expect that the inclusion of other important image quality indices with a greater number of patients' cases will enable the establishment of integrated platforms for monitoring both CT image quality and radiation dose.

소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰 (Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality)

  • 이님;조현혜;이소미;유선경
    • 대한영상의학회지
    • /
    • 제84권1호
    • /
    • pp.240-252
    • /
    • 2023
  • 목적 소아 환자에서 두부 컴퓨터단층촬영(이하 CT)에 대한 딥러닝 이미지 재구성(deep learning image reconstruction; 이하 DLIR; TrueFidelity; GE Healthcare, Milwaukee, WI, USA)의 효과를 평가하고자 한다. 대상과 방법 총 126개의 소아 두부 CT 이미지를 수집했으며, adaptive statistical iterative reconstruction (이하 ASiR)-V를 사용한 반복적 재구성 및 세 가지 수준의 DLIR을 사용한 재구성을 시행하였다. 각 이미지 세트 그룹은 환자의 연령에 따라 4개의 그룹으로 구분하였으며 각 연령군의 임상 및 방사선량 관련 데이터를 검토하였다. 양적 매개 변수에는 signal to noise ratio (이하 SNR) 및 contrast to noise ratio (이하 CNR)가 포함되었으며 질적 매개 변수로 영상의 잡음(noise), 회백질의 구분 정도, 선명도, 인공물 및 수용 가능성(acceptability), 영상의 질감이 포함되었고 이에 대한 평가와 비교를 시행하였다. 결과 모든 연령 그룹의 모든 수준의 SNR 및 CNR은 높은 수준의 DLIR 사용 시 증가하였다. ASiR-V와 비교했을 때 높은 수준의 DLIR은 SNR 및 CNR이 개선되었다(p < 0.05). 그리고 DLIR의 수준이 증가될수록 순차적인 잡음 감소, 회백질 구분 개선, 선명도 개선이 나타났다. 이러한 변수들에서 높은 수준의 DLIR 사용 시 ASiR-V와 유사한 정도의 수치가 측정되었다. 인공물과 수용 가능성의 경우에 적용된 DLIR 수준 간에 큰 차이를 보이지 않았다. 결론 소아 두부 CT에 고수준 DLIR을 적용하면 영상의 노이즈를 줄일 수 있으나 인공물 처리에 대한 개선이 필요하다.

수정된 generalized Landweber 방법을 이용한 ECT 영상 복원 (Image reconstruction in electrical capacitance tomography based on modified generalized Landweber method)

  • 이성훈;장재덕;김용성;김경연;최봉열
    • 전자공학회논문지SC
    • /
    • 제43권5호
    • /
    • pp.68-79
    • /
    • 2006
  • ECT는 측정된 커패시턴스 값을 이용하여 유전 물체의 유전율 분포를 가시화하기 위해 사용되는 비접촉 영상 복원 기술이다. 영상 복원시 수렴 속도 개선과 영상의 질 향상을 위해 다양한 반복적 영상 복원 방법들이 있으며, Landweber 방법은 널리 사용되고 있는 ECT의 영상 복원 방법 중 하나이다. 본 논문에서는 ECT 영상 복원에서 수렴 속도를 개선하기 위해 수정된 generalized Landweber 방법을 제안한다. 특히, Shaping 행렬을 가지는 generalized Landweber 방법에 가속항을 추가하고 최적화 계수를 해석적으로 결정한다. 다양한 컴퓨터 모의 실험을 통해 제안한 방법의 타당성을 입증한다.

전산화단층촬영에서 관전압과 관전류, 통계적 반복재구성법에 따른 화질과 피폭선량 (Quality of Image and Exposure Dose According to kVp, mA and Iterative Reconstruction in Computed Tomography)

  • 차상영;박재윤;이용기;김정훈;최재호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.385-392
    • /
    • 2017
  • 본 연구는 전산화단층촬영에서 관전압과 관전류에 따른 화질과 피폭선량을 연구하고 None IR과 IR (Iterative Reconstruction)의 단계에 따른 영상의 SNR(Signal to Noise Ratio)을 비교하여 영상 화질의 개선정도에 대하여 확인해보고자 하였다. Image J를 이용하여 화질을 측정한 결과 관전압의 증가에 따라 HU (Hounsfield units)와 BN(Background Noise)은 감소하였으며, 이와 반대로 SI (Signal Intensity)와 SNR, $CTDI_{vol}$ (CT dose in dex volume)은 관전압이 높아질수록 증가하였으며, BHU(Background Hounsfield Units)의 변화는 없었다. 관전류의 증가로 인해서 BN이 감소하였고, 반대로 SNR과 CTDI은 증가하였다. 또한 IR의 단계가 높아질수록 HU와 SI, BN이 낮아지고, SNR이 약 10~60% 향상됨을 알 수 있었다. 이를 토대로 임상에서 IR 적용 시 단계적 접근 방식으로 관전압과 관전류를 미세 조정하여 점차적으로 방사선량을 줄여 나가야 할 것이다.