• Title/Summary/Keyword: Isotropic Probe

Search Result 9, Processing Time 0.024 seconds

3-Axial Isotropic Electric-Field Probe Design with Resistor-Loaded Short Dipole (저항 부하된 소형 다이폴을 이용한 3축 등방성 전기장 프로브 설계)

  • Moon, Sung-Won;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.246-249
    • /
    • 2017
  • In this paper, we designed the 3-axis isotropic electric-field measurement probe using resistor-loaded short dipole with lumped chip resistors. The designed probe shows good isotropic characteristics as well as wideband and low sensitivity. The isotropic characteristics of ${\pm}0.39dB$ from 100 kHz to the 3 GHz band were derived and the reception sensitivity was 0.1 V/m. The frequency response is within 3 dB of the whole section, especially ${\pm}1.3dB$ from 150 kHz to 3 GHz, which is superior to the conventional electric field probe with short dipoles.

Design and Fabrication of an Electric-Field Probe Using Short Dipole Antennas (소형 이극안테나를 이용한 전계강도 프로브의 설계 및 제작)

  • 김혁제;박동철;이애경;심환우
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.1
    • /
    • pp.3-9
    • /
    • 1995
  • An isotropic electric-field probe, capable of characterizing and quantifying electromagnetic field, was fabricated. The probe consists of three short dipole antennas, a beam-lead Schottky diode and the high resistive transmission line. In order to get the isotropic response three mutually orthogonal dipoles are configured to form the probe. The probe's short dipole elements allow measurements of electric fields from 300MHz to 2GHz with a flatness of .+-. 2.9dB. The mutually orthogonal dipole configration shows a .+-. 1.2dB deviation in the isotropic response with respect to angle.

  • PDF

Fatigue damage detection of CFRP using the electrical resistance change method

  • Todoroki, Akira;Mizutani, Yoshihiro;Suzuki, Yoshiro;Haruyama, Daichi
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.4
    • /
    • pp.350-355
    • /
    • 2013
  • Electrical resistance change measurements were performed, to detect fatigue damage of a quasi-isotropic CFRP and cross-ply CFRP laminates. A four-probe method was used to measure the exact electrical resistance change. A three-probe method was used to measure the electrical contact resistance change, during long cyclic loading. The specimen side surface was observed using a video-microscope to detect damage. The measured electrical resistance changes were compared with the observed damage. The results of this study show that the electrical resistance increase of the quasi-isotropic laminate was caused by a delamination crack between ${\pm}45^{\circ}$ plies. Matrix cracking caused a small electrical resistance increase of the cross-ply laminate, but the decreased electrical resistance caused by the shear-plastic deformation impedes matrix-cracking detection.

Characteristics of the Detection Voltages of an E-field Sensing Probe in SAR Measurement System (전자파 비흡수율(SAR) 측정용 전기장 프로브의 검파 전압 특성)

  • Gimm Youn-Myoung;Lee Seung-Bae;Kim Ki-Hwea
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.217-221
    • /
    • 2005
  • The E-field intensity by mobile handsets in a phantom is measured by a 3 axes miniature probe. The detected DC voltage by a Schottky diode in a probe has nonlinear characteristics by itself. If a pertinent diode compression point (DCP) is applied for the compensation specific absorption rate(SAR) as much as 200 W/kg can be measured with a good measurement accuracy.

Fabrication of Bump-type Probe Card Using Bulk Micromachining (벌크 마이크로머시닝을 이용한 Bump형 Probe Card의 제조)

  • 박창현;최원익;김용대;심준환;이종현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.661-669
    • /
    • 1999
  • A probe card is one of the most important pan of test systems as testing IC(integrated circuit) chips. This work was related to bump-type silicon vertical probe card which enabled simultaneous tests for multiple semiconductor chips. The probe consists of silicon cantilever with bump tip. In order to obtain optimum size of the cantilever, the dimensions were determined by FEM(finite element method) analysis. The probe was fabricated by RIE(reactive ion etching), isotropic etching, and bulk-micromachining using SDB(silicon direct bonding) wafer. The optimum height of the bump of the probe detemimed by FEM simulation was 30um. The optimum thickness, width, and length of the cantilever were 20 $\mum$, 100 $\mum$,and 400 $\mum$,respectively. Contact resistance of the fabricated probe card measured at contact resistance testing was less than $2\Omega$. It was also confirmed that its life time was more than 20,000 contacts because there was no change of contact resistance after 20,000 contacts.

  • PDF

Infrared Spectroscopic Study of Molecular Hydrogen Bonding in Chiral Smetic Liquid Crystal

  • Jang, Won-Gun
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.18-31
    • /
    • 2001
  • We utilize Fourier transform infrared (IR) spectroscopy to probe intramolecular hydrogen bonding in $smectic-C^{\ast}$ liquid crystal phases. Infrared spectra of aligned smectic liquid crystal materials vs. temperature and of isotropic liquid crystal mixtures vs. concentration were measured in homologs, both with and without hydrogen bonding. Hydrogen bonding significantly changes the direction and magnitude of the vibrational dipole transition moments, causing marked changes in the IR dichroic absorbance profiles of hydrogen bonded molecular subfragments. A GAUSSIAN94 computation of the directions, magnitudes, and frequencies of the vibrational dipole moments of molecular subfragments shows good agreement with the experimental data. The results show that IR dichroism can be an effective probe of hydrogen bonding in liquid crystal phases.

  • PDF

Second Harmonic Generation study on the transport dynamics of small molecules across liposome bilayers

  • Kim, Joon-Heon;Kim, Mahn-Won
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.79-79
    • /
    • 2003
  • SHG (Second harmonic generation) can be used to probe the surface of centrosymmetric particles suspended in bulk isotropic solution, because it is forbidden in centrosymmetric media under the dipole approximation. Using this technique, we can study the transport dynamics of small organic dye molecules across liposome bilayers. Because molecules adsorbed on the outer layer are in opposite direction with that on the inner layer by symmetry, the SH field is proportional to the difference between the number density of dye molecules on both sides of the bilayer, and the time dependence of the SH intensity is related to the time constant of the molecular transportation of dye molecules across liposome bilayers.

  • PDF

Assessment and Analysis of Human EMF Exposure to UHF RFID System (UHF 대역 RFID 시스템에서 전자기장의 인체노출량 측정 및 분석)

  • Byun, Jin-Kyu;Yun, Jae-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.132-140
    • /
    • 2009
  • For human exposure assessment of UHF RFID system, electric field distribution of commercial 900[MHz] RFID antenna was measured and analyzed. Also, SAR(Specific Absorption Rate) of RFID antenna was calculated by simulation, and compared with basic restrictions in EMF guidelines. For EMF exposure assessment according to EN and IEC standards, the reader was tested for the normal operation, and electric field from RFID antenna was measured at various distances and angles. For electric field measurement, narrow band isotropic electric field probe was used, and the measurements were made at 0.3, 0.5, 1.0 and 1.5[m] for every 15[$^{\circ}$] angle from the antenna. Also, the rationale for measurement distance in EN and IEC standards is analyzed from the measurement results.

A Study on the Magnetic Properties of Ion Irradiated Cu/Co Multilayer System

  • Kim, T.Y.;Chang, G.S.;Son, J.H.;Kim, S.H.;Shin, S.W.;Chae, K.H.;Sung, M.C.;Lee, J.;Jeong, K.;Lee, Y.P.;;Whang, C.N
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.163-163
    • /
    • 2000
  • In this research, we used the ion irradiation technique which has an advantae in improving intentionally the properties of surface and interface in a non-equilibrium, instead of the conventional annealing method which has been known to improve the material properties in the equilibrium stat. Cu/Co multilayered films were prepared on SiN4/SiO2/Si substrates by the electron-beam evaporation for the Co layers and the thermal evaporation for the Cu layers in a high vacuum. The ion irradiation with a 80keV Ar+ was carried out at various ion doses in a high vacuum. Hysteresis loops of the films were investigated by magneto-optical polar Kerr spectroscopy at various experimental conditions. The change of atomic structure of the films before and after the ion irradiation was studied by glancing angle x-ray diffraction, and the intermixing between Co and Cu sublayers was confirmed by Rutherford backscattering spectroscopy. The surface roughness and magneto-resistance were measured by atomic force microscopy and with a four-point probe system, respectively. During the magneto-resistance measurement, we changed temperature and the direction of magnetization. From the results of experiments, we found that the change at the interfaces of the Cu/Co multilayered film induced by ion irradiation cause the change of magnetic properties. According to the change in hysteresis loop, the surface inplane component of magnetic easy axis was isotropic before the ion irradiation, but became anisotropic upon irradiation. It was confirmed that this change influences the axial behavior of magneto-resistance. Especially, the magneto-resistance varied in accordance with an external magnetic field and the direction of current, which means that magneto-resistance also shows the uniaxial behavior.

  • PDF