• 제목/요약/키워드: Isolation method

검색결과 1,593건 처리시간 0.026초

고성능 절연형 벅-부스트 컨버터의 특성 해석에 관한 연구 (A Study on the Characteristic analyses of High Performance Buck-Boost Converter added Electric Isolation)

  • 곽동걸;정도영;이봉섭;김춘삼;심재선;양기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.142-144
    • /
    • 2008
  • This paper is studied on the characteristic analyses of a high performance buck-boost converter added electric isolation by using a soft switching method. To be achieved of a high performance system, the proposed buck-boost converter is constructed by using a partial resonant circuit. The control switches using in the converter are operated with soft switching for a Partial resonant method. The controlling switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the converter efficiency is high. And the proposed converter is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed converter is adopted with the system development of high efficiency. The soft switching operation and system efficiency of the proposed converter is verified by digital simulation and experimental results.

  • PDF

마찰복원형 지진격리장치가 설치된 케이블교량의 성능 기반 내진설계법 개선(II-내진설계 절차 제안) (Improvement of the Performance Based Seismic Design Method of Cable Supported Bridges with Resilient-Friction Base Isolation Systems (II-Proposal for the Seismic Design Procedure))

  • 길흥배;박선규;한경봉;윤완석
    • 한국지진공학회논문집
    • /
    • 제24권4호
    • /
    • pp.169-178
    • /
    • 2020
  • In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the "Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges" is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.

추백리 혈청검사 양성 산란계로부터 Salmonella속균 분리 (Isolation of Salmonella from the layer chickens reacting in pullorum-typhoid agglutination test)

  • 류재윤;전무형;장경수;손현수;곽학구;박경재;우용구
    • 한국동물위생학회지
    • /
    • 제22권3호
    • /
    • pp.221-237
    • /
    • 1999
  • To investigate the specificity of rapid slide agglutination test for pullorum-gallinarum diseases and to obtain a basic data for avian salmonellosis control, salmonella isolation was peformed for the layer chickens positively reacted in pullonlm-typhoid agglutination test. The biochemical, serological and antimicrobial properties of the isolates were examined. The results obtained through this study were summarized as follows; 1. Of 2,384 chickens tested by the agglutination test, 606 chickens (25.4%) were positive reactors. 154 of 606 reactors and 49 of the non-reacting chickens were investigated for salmonella isolation, resulting in isolation of 68 strains of salmonellae from 27 chickens. 2. By organs, the isolation frequency from liver, cecum, spleen, ovary and gall bladder showed 8.9% (18 strains), 8.9% (18 strains), 7.4% (15 strains), 4.4% (9 strains) and 3.9% (8 strains), respectively. 3. By culture medium the combination of selenite broth and MacConkey agar revealed the highest isolation rate and the enrichment culture by delayed secondary enrichment culture method was found the most effective for salmonella isolation. 4. The serotypes of 68 salmonella isolates were identified as 3 strains of S pullorum, 24 strains of S gallinarum, 15 strains of S typhimurium, 8 strains of S enteritidis, 7 strains of S paratyphi A, 5 strains of S typhimurium and 6 strains of the other salmonellae. 5. The serotypes of 8 salmonella strains isolated from 49 chickens non-reacting in pullorum-typhoid agglutination test were identified as 3 strains of S typhimurium and 5 strains of S infantis. 6. When 24 chickens of which 68 strains of salmonellae isolated were examined by microplate agglutination test, the average antibody titer for pullorum antigen was $2^{5.25}$. The chickens at antibody titer between $2^3$ and $2^5$ showed the higher frequency of isolation as compared with the chickens at the other titers. 7. When salmonella isolates were tested the antimicrobial drug sensitivity by disk diffusion method, S paratyphi A were highly sensitive by 100% to ATM and GM, S typhimurium, by 88% to AM, CIP, IMP and TN, S infantis, by 100% to AM, CRO, ENR and PIP, S enteritidis,by 100% to IMP and PIP, S pullorum, by 100% to ATM, CRO, ENR and PIP and S gallinarum, by 92% to CRO, CIP and PIP.

  • PDF

격리받침 위에 놓인 Slender 강체 블록의 동적거동 (Dynamics of Slender Rigid Blocks Mounted on the Seismic Isolation System)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.448-454
    • /
    • 2000
  • Piled multi-block system has been frequently adopted in the historic structures or monuments of cultural heritage. It is well known that such a structural system is very vulnerable to the earthquake shaking. If the structure is of slender type, then it may experience overturning at very low level intensity of ground shaking. One of the methods used to protect such structures from earthquake is seismic isolation system. But the behavior of multi-block systems mounted on the isolated basis is not well understood yet. In this paper we investigate the dynamic behavior of single slender rigid block mounted on the three different isolation systems, i.e., P-F system, FPS and LRB system. Sliding at the isolation interface of P-F system and FPS is formulated based on Coulomb friction. The mounted single block is assumed undergoing rocking or sticking only. Impacting of a single block is described using distinct element method (DEM). Free vibrations due to a prescribed initial conditions are studied. Responses to the harmonic excitation and earthquake motions are calculated

  • PDF

공압 제진 시스템의 해석과 설계: II. 시뮬레이션, 실험과 설계 최적화 (Analysis and Design of a Pneumatic Vibration Isolation System: Part II. Simulation, Experimental Verification and Design Optimization)

  • 문준희;박희재
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.137-146
    • /
    • 2004
  • This is the second of two companion papers concerned with the analysis and design of a pneumatic vibration isolation system. The properties of the system are clarified by observation of the transmissibility surface calculated by the models and algorithm developed in the first paper of this research. It Is shown that the nonlinear model proposed in this research is more closer to experimental results than the linear model that have been used in previous studies. The design optimization of the major design variables that affect the performance of the system is achieved by using the condition for attenuation, disturbance rejection and maximum damping in resonance peak. The design space search method is adopted for the optimization of the orifice area. The models, transmissibility calculation algorithms and design optimization techniques developed in this research are shown to be greatly helpful to the optimal design of the pneumatic vibration isolation system by experiment.

Probabilistic seismic demand models and fragility estimates for reinforced concrete bridges with base isolation

  • Gardoni, Paolo;Trejo, David
    • Earthquakes and Structures
    • /
    • 제4권5호
    • /
    • pp.527-555
    • /
    • 2013
  • This paper proposes probabilistic models for estimating the seismic demands on reinforced concrete (RC) bridges with base isolation. The models consider the shear and deformation demands on the bridge columns and the deformation demand on the isolation devices. An experimental design is used to generate a population of bridges based on the AASHTO LRFD Bridge Design Specifications (AASHTO 2007) and the Caltrans' Seismic Design Criteria (Caltrans 1999). Ground motion records are used for time history analysis of each bridge to develop probabilistic models that are practical and are able to account for the uncertainties and biases in the current, common deterministic model. As application of the developed probabilistic models, a simple method is provided to determine the fragility of bridges. This work facilitates the reliability-based design for this type of bridges and contributes to the transition from limit state design to performance-based design.

인버터의 직류링크 전압 검출 및 궤환을 위한 절연앰프 회로 (Isolation Amplifier Circuits for Sensing and Feedback of the Inverter DC-Link Voltage)

  • 김경서
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.522-529
    • /
    • 2014
  • This study proposes an isolation amplifier circuit for the sensing and feedback of inverter DC-link voltage, which is inevitable for the precise control of inverter output voltage. The isolation amplifier consists of a pulse-width modulator and a pulse transformer with dual secondary windings. The accuracy of the proposed circuit depends on the precise matching of filter parameters in dual secondary circuits. The influences of parameter inaccuracy on the amplifier performances are analyzed. A modified circuit is proposed to reduce the dependency on filter parameters. The validity of the proposed method is verified through simulation and experiment.

Reproducible Chemical Mechanical Polishing Characteristics of Shallow Trench Isolation Structure using High Selectivity Slurry

  • Jeong, So-Young;Seo, Yong-Jin;Kim, Sang-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권4호
    • /
    • pp.5-9
    • /
    • 2002
  • Chemical mechanical polishing (CMP) has become the preferred planarization method for multilevel interconnect technology due to its ability to achieve a high degree of feature level planarity. Especially, to achieve the higher density and greater performance, shallow trench isolation (STI)-CMP process has been attracted attention for multilevel interconnection as an essential isolation technology. Also, it was possible to apply the direct STI-CMP process without reverse moat etch step using high selectivity slurry (HSS). In this work, we determined the process margin with optimized process conditions to apply HSS STI-CMP process. Then, we evaluated the reliability and reproducibility of STI-CMP process through the optimal process conditions. The wafer-to-wafer thickness variation and day-by-day reproducibility of STI-CMP process after repeatable tests were investigated. Our experimental results show, quite acceptable and reproducible CMP results with a wafer-to-wafer thickness variation within 400$\AA$.

Improving the Isolation of MIMO Antennas Using Split Ring Resonators

  • Lee, Young-Ki;Chung, Hae-Il;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.303-308
    • /
    • 2010
  • This paper proposes a method for improving the isolation characteristic of multi-input multi-output (MIMO) antennas using a split ring resonator (SRR) array structure between the two radiating elements. The fabricated antenna satisfies the 10 dB return loss requirement in the Mobile-WiMAX frequency band from 3.4 GHz to 3.6 GHz. The isolation between the two radiating elements is improved by approximately 20 dB at the center frequency by inserting a SRR array structure. The measured peak gains of the two elements are 2.3 dBi and 2.4 dBi, respectively.

퍼지논리를 이용한 다중관측자 구조 FDIS의 성능개선 (Performance Improvement of Multiple Observer based FDIS using Fuzzy Logic)

  • 류지수;이기상
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.444-451
    • /
    • 1999
  • A diagnostic rule-base design method for enhancing fault detection and isolation performance of multiple obsever based fault detection isolation schemes (FIDS) is presented. The diagnostic rule-base has a hierarchical framework to perform detection and isolation of faults of interest, and diagnosis of process faults. The decision unit comprises a rule base and a fuzzy inference engine and removes some difficulties of conventional decision unit which includes crisp logic with threshold values. Emphasis is placed on the design and evaluation methods of the diagnostic rult-base. The suggested scheme is applied to the FDIS design for a DC motor driven centrifugal pump system.

  • PDF