• 제목/요약/키워드: Isolation hospital

검색결과 330건 처리시간 0.031초

임상검체에서 Pseudomonas spp.의 분리빈도와 항균제 감수성 (Isolation Frequency and Antimicrobial Susceptibility of Pseudomonas Species from Clinical Materials)

  • 신현성;박연보;조경진
    • 대한임상검사과학회지
    • /
    • 제39권3호
    • /
    • pp.167-177
    • /
    • 2007
  • From the total 121,294 clinical materials submitted to the Department of Laboratory Medicine of "C" hospital from December 1, 2004 to November 30, 2006, 3,408 Pseudomonas spp. were isolated. The isolation frequencies of Pseudomonas spp. were as follows, P. aeruginosa 95.5%, P. putida 2.5%, P. fluorescens 0.8%, along with low frequencies of P. luteola, P. alcaligenes, P. stutzeri, P. oryzihabitants, P. mendocina and unidentified Pseudomonas species. The isolation rates of Pseudomonas spp. according to season and sex were evenly distributed. The isolated frequency of Pseudomonas spp. in male was two times higher than that of in female showing significantly more male patients in surgical areas and more female patients in internal areas (p<0.001). In monthly analysis, Pseudomonas spp. were the most frequently isolated in July (10.4%), but lowest in February (5.6%). Half of Pseudomonas spp. were isolated from sputum (48.2%). In the susceptibility analysis of Pseudomonas spp. by VITEK II AST cards, the Pseudomonas spp showing higher susceptibility against antimicrobial agents were piperacillin/tazobactam (82.7%) in P. aeruginosa; amikacin (84.7%), colistin (83.3%) in P. putida; and amikacin (96.3%), cefepime (87.5%), ceftazidime (87.5%) ciprofloxacin (92.3%), colistin (88.5%) gentamicin (96.2%), isepamicin (96,1%), meropenem (92.3%), netilmicin (96.0%), piperacillin/ tazobactam (95.4%) and tobramycin (92.6%) in P. fluorescens.

  • PDF

중증 호흡기 감염병 진료를 고려한 음압격리병동부의 건축계획 (A Development of Design Guidelines for the Negative Pressured Isolation Units Controlling Severe Respiratory Infectious Disease)

  • 권순정;윤형진
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권3호
    • /
    • pp.45-56
    • /
    • 2016
  • Purpose: The MERS(Middle East Respiratory Syndrome) outbreaks in Korea highlighted dramatically the failings of traditional hospital environment for controlling or preventing infections among both patients and healthcare workers. MERS is transmitted by droplets that can be airborne over a limited area. The point should be emphasized that MERS in South Korea was predominantly a hospital-acquired (not a community-acquired) infection, because approximately 93% of MERS cases were resulted from exposure in hospital settings. This paper tries to suggest the design guidelines of negative pressured isolation ward for the sake of proper control of severe respiratory infectious diseases. Methods: Literature survey on the design guideline and regulations of airborne infection wards in Korea, Europe U.K. and CDC of U.S. have been carries out. 4 special infection wards in Hongkong, Germany, Japan and Korea have been surveyed in order to make the best use of the experiences related to facility design and operations. Results: Operating system influencing the facility design, space organizations of infectious ward including required space and zoning, and circulations of patients, staffs and materials are proposed. Implications: The results of this paper can be the basic data for the design of the airborne infection ward and relevant regulations. Afterwards in-depth study such as the development of space standards for the single bedroom, locker room and so on could be explored.

몬테카를로 모의 모사를 이용한 방사성옥소 2인 치료병실의 안전성 평가 (Evaluation of Stability using Monte Carlo Simulation in 2 People Isolation Treatment Room of Radiation Iodine)

  • 장동근;고성진;김창수;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.385-390
    • /
    • 2016
  • 방사성옥소를 이용한 2인 치료격리병실은 환자간의 불필요한 피폭선량을 유발하게 된다. 이에 본 연구에서는 방사성 옥소를 섭취 후 배설 없이 모두 인체에 분포하였다는 가정 하에 방사성 옥소의 물리적 특성 및 생물역동학적 정보를 제외한 보수적인 관점으로 몬테카를로 모의 모사를 이용한 2인 치료격리병실의 안전성을 평가하고자 한다. 실험 결과 방사성옥소에서 방출되는 364 keV의 감마선은 공기층 약 30 cm 또는 납 차폐체 3 mm가 반가층으로 작용됨을 파악할 수 있었으며, 환자간 거리 및 납 차폐체의 두께를 이용하였을 때, 입원기간(48시간)동안 상대방 환자로부터 받게 되는 외부 피폭선량은 5 mSv 이하로 법적 격리 기준선량 보다 낮게 나타남으로써 2인 치료격리병실의 효율적인 관리가 가능한 것으로 분석되었다.

Relation of Handwashing and Isolate of Bacteria from Mobile Phones of Healthcare Workers in a University Hospital

  • Choi, Min-Gyu;Kim, Sang-Ha;Park, Kyu-Ri;Kim, Young-Kwon;Kim, Jungho;Yu, Young-Bin
    • 대한의생명과학회지
    • /
    • 제27권4호
    • /
    • pp.310-316
    • /
    • 2021
  • Mobile phones used by healthcare workers are not only an indicator of the contamination of healthcare associated bacteria, but can also be another source of infection. The number and time of handwashing, mobile phone operation time and disinfection were highly relation with the bacterial contamination on the surface of mobile phone. Healthcare associated bacteria isolated from the mobile phone surface were 28 MRCoNS (48.3%), 14 S. aureus (24.2%), 3 MRSA (5.2%), 5 A. baumannii (8.6%), 3 MRAB (5.2%), 3 Entrococcus spp. (5.1%), 2 Pantoea spp. (3.4%), 2 A. lowffii (3.4%), 1 E. cloacae (1.7%), 1 P. stutzeri (1.7%), and P. mirabillis (1.7%). For isolation according to department, 2 MRAB from the emergency room and 1 MRSA from intensive unit, the radiology team and the rehabilitation medical team, respectively were isolated. As a result of the relation of isolates from the department of patient contact (ER, RT, GW, CP, ICU, RMT), the bacterial isolation rate was 75% and the department of patient non-contact (MRT) was 10%.

위암에서 CK20과 CEA의 RT-PCR을 이용한 수술조작 전후 유출 정맥과 복막에서의 미세전이의 검출 (Use of RT-PCR for CK20 and CEA mRNA to Detect of Micrometastasis in the Draining Venous Blood and the Peritoneum in Gastric Cancer Patients)

  • 주재균;이지희;고양석;김정철;류성엽;김동의;김영진
    • Journal of Gastric Cancer
    • /
    • 제3권3호
    • /
    • pp.128-133
    • /
    • 2003
  • Purpose: The benefits of the 'no-touch' isolation techniquethat is usually performed to prevent the circulation of tumor cells are not evident. The aim of this study was to determine whether the no-touch isolation technique for treating gastrointestinal cancers could prevent the circulation of tumor cells detected by reverse transcriptase polymerase chain reaction (RT-PCR). Matrials and Methods: By using RT-PCR to amplify mRNAs for two specific epithelial markers, carcinoembryonic antigen (CEA) and cytokeratin 20 (CK-20), we examined 34 gastric cancer patients who had been histologically diagnosed and 22 patients had undergone serosal and peritoneal brushing. Results: In 10 ($29.4\%$) of the 34 gastric cancer patients, we detected CK20 mRNA before manipulation, and in 17 ($51.5\%$) of those patients, after we detected it. The density of the CK20 mRNA band was increased in 11 cases ($33.3\%$) and the density was decreased in 2 cases ($6.1\%$). In 16 ($48.5\%$) of the 34 gastric cancer patients, we detected CEA mRNA before manipulation, and in 17 ($51.5\%$) patients after we detected it. The density of the CEA mRNA band was increased in 8 cases ($24.2\%$) and decreased in 3 cases ($9.1\%$). Conclusion: These result suggest that the ' no-touch isolation technique ' might be useful when operating on advanced gastric cancer patients and that serosal or Douglas pouch brushing can be used to determine the status of micrometastasis.

  • PDF

국내 200병상이상 의료기관의 다약제 내성균 감염관리 실태조사 (Current Status of Infection Control of Multidrug Resistant Organisms in Hospitals with more than 200beds in the Republic of Korea)

  • 오향순
    • 보건의료산업학회지
    • /
    • 제8권4호
    • /
    • pp.163-173
    • /
    • 2014
  • This study was performed to investigate the current status of isolation precautions of multidrug resistant organisms(MDROs) in general hospitals with more than 200bed. The questionnaires were mailed from 3rd, April 2013 to 30th, April 2013. Methicillin resistant Staphylococcus aureus:(MRSA), vancomycin resistant Staphylococcus aureus:(VRSA), vancomycin resistant Enterococcus(VRE), multidrug-resistant Acinetobacter baumannii, carbapenem-resistant Enterobacteriaceae multidrug-resistant Pseudomonas aeruginosa were enrolled. MRSA(100.0%) and VRE(98.7%) were isolated respectively. VRE(97.3%) and MRSA(64.0%) were regulated strictly respectively. VRE(91.5%) and VRSA(50.7%) were isolated in a single room respectively. Hospital being located in Seoul(p<0.001), and beds(${\geq}600$)(p=0.008) were different significantly. The isolation space limitation(71.1%) was the highest difficulty. The development of refunding the costs of the extra supplies and other hygienic materials for infection control was discovered as the most urgent strategy.

감염병전문병원의 병동부 및 중환자부 영역 구성에 관한 연구 (A Study on the Zoning of Wards and Intensive Care Units (ICUs) in the Infectious Disease Hospital)

  • 이주랑;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권3호
    • /
    • pp.17-28
    • /
    • 2023
  • Purpose: This study aims to provide basic data for the future construction plans of the Infectious Disease Hospitals by analyzing the area composition and required room ratios in the wards and ICU of currently under-construction infectious disease hospitals. Methods: 3 Methods have been used in this paper. 1) This study conducted a literature review on major considerations and related guidelines for hospitals specializing in infectious diseases using existing data. 2) Based on the objects and activities of the hospital space, zones and areas were set for each department according to infection control. 3) Based on the established zones and areas, basic plan drawings of three hospitals specializing in infectious diseases currently under construction were collected and architectural drawing analysis was performed. Results: 1) Infectious Diseases Hospital must have a spatial organization that can accommodate patient isolation, infection control, efficiency of medical service, and changes. 2) Zones for infection control are divided into negative pressure and non-negative pressure zones based on airborne precaution isolation. It is divided into clean and contaminated zone according to class of cleanliness by Aseptic technique. Areas are classified by objects (patients, healthcare workers, supplies) and activities (access, medical treatment, support), and a system for organizing space is established based on this. 3) By analyzing the area composition of each departmental area, each required room, and each required space in the wards and intensive care units, it provides basic data for the spatial organization for architectural planning of the infectious disease hospital. Implication: It can be used as basic data when planning related facilities by analyzing the characteristics of the space plan of the required room according to the relationship between activities, movement lines, and operation plans based on user behavior.

종합병원의 환기설비 사례 연구 (A Case Study on the Ventilation System of the General hospital)

  • 정종림
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.