• 제목/요약/키워드: Isolation hospital

검색결과 330건 처리시간 0.025초

중환자실 간호사들의 손 소독제에 따른 소독효과 및 MRSA 분리 (The Effect of Disinfection and the MRSA Isolation from Hand Disinfectant in ICU Nurses)

  • 박선남;류경화;정정임;박옥순
    • 기본간호학회지
    • /
    • 제13권3호
    • /
    • pp.359-367
    • /
    • 2006
  • Purpose: This study was a within subject repeated pretest-posttest design done to compare the effect of disinfection and the degree of MRSA(Methicillin- resistant staphylococcus aureus) isolation from hand disinfectant in ICU nurses. Method: Out of the total internal medicine/surgery ICU nurses at a university hospital in Seoul, 29 female nurses who were participating in direct patient care were participants in this study. After collection of samples, Staphylococcus aureus and MRSA were isolated from the palms, nails and nasal cavities of the nurses according to disinfectants (soap and beta-scrub). Results: The effect of disinfection was greater in the beta-scrub group than in the soap group, and the effect of disinfection on palms was higher in the beta-scrub group than in the soap group. As for the degree of MRSA isolation, there was more isolation in palms in the soap group than in the beta-scrub group but there was no difference in the degree of MRSA isolation from the hand disinfectant in nails and nasal cavities. Conclusion: Beta-scrub showed a superior prolonged effect against transient bacteria compared with soap. Further, to reduce MRSA infection, we recommend interventions focused on these aspects.

  • PDF

CBRNE 재난 시 격리이송을 위한 장치 개발에 관한 탐색적 연구 (An exploratory study on the development of a device for isolation unit in CBRNE disaster)

  • Ham, Seung Hee;Park, Namkwun;Yoon, Myong O
    • 한국재난정보학회 논문집
    • /
    • 제14권1호
    • /
    • pp.65-71
    • /
    • 2018
  • 본 연구에서는 CBRNE 사고 및 공격에 의한 대규모 재난 발생 시 오염원 확산을 최대한으로 방지하면서 환자상태별 최적의 이송환경을 제공하기 위한 격리캡슐을 개발하는데 있어 필요한 성능적 기능적 요구사항을 고찰하고자 하였다. 이를 위하여 기존에 개발된 제품들의 특성을 파악함으로써 현장에서 즉각 활용을 어렵게 하는 곤란요소를 보완 수정할 수 있는 방안을 제시하였다. 연구결과, 현장에서 즉각 활용을 용이하게 하기 위한 격리이송장치를 개발하기 위해서 (1)기본기능, (2)효율적인 현장활용성, (3)격리이송장치 인터페이스 및 모듈간 결합방안의 각 고려요소에 대하여 제시하였다.

The first virus isolation and partial characterization of equine herpesvirus-4 in a horse, South Korea

  • Choi, Eun-Jin;Lee, Hyun-Kyoung;Lee, Kyoung-Hyun;So, Byoung-Jae;Song, Jae-Young;Do, Jae-Chul;Yang, Seon-Joo;Lee, Hyun-Chul;Yang, Young-Jin
    • 한국동물위생학회지
    • /
    • 제38권2호
    • /
    • pp.141-144
    • /
    • 2015
  • An equine herpesvirus-4 (EHV-4) was isolated in nasal swabs collected in a horse showing respiratory clinical signs. Equine dermis cells inoculated with the sample were observed with characteristic viral cytopathic effects after 3 days of postinoculation and the infected cells exhibited bright intracelluar fluorescence by indirect immunofluorescence assay. At the nucleotide level, the partial glycoprotein B gene of the Korean EHV-4 isolate (K001) had 99.9% identity to 1942 strain (GenBank No. M26171). To author's knowledge, the report describes the first isolation and partial characterization of EHV-4 in Korea. The virus can be used for further study of EHV-4.

일반병실을 음압격리병실로 전환 시 병실 전환 방식에 관한 연구 - 국가지정입원치료병상과 긴급치료병상을 중심으로 (A Study on the Room Conversion Type when Converting a Patient Bed-Room into a Negative Pressure Isolation Room - Focused on Nationally designated Isolation Wards and Urgent Isolation Wards)

  • 김지윤;이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권4호
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose: The 2015 Middle East Respiratory Syndrome (MERS) outbreak and the recent COVID-19 pandemic have highlighted the lack of negative pressure isolation rooms and the fragility of the healthcare system. The need for healthcare facility transformation for respiratory infectious diseases has become more prominent due to COVID-19, and the purpose of this study is to provide a foundation for the rapid, economical, and safe construction of negative pressure isolation wards. Methods: This study analyzes the current status of hospitals that have been converted to negative pressure isolation rooms, and provides architectural plans and examples to provide a reference for bedroom change. Research data of this study have been obtained by analyzing the drawings of negative pressure isolation wards of nationally designated inpatient treatment beds and urgent isolation beds. In addition, the relevant literature of urgent isolation beds has been analyzed to derive bedroom change type. Result: In this study, a total of 21 isolation bed conversion methods have been presented. Implications: In order to change efficiently from a general ward to an isolation ward, it is necessary to consider the actual hospital's infectious disease transmission patterns and facility conditions.

INTEGRATION OF CONSTRUCTION TECHNIQUES FOR SPECIAL ISOLATION WARDS OF HOSPITAL BUILDINGS

  • Chi-Su Tai ;Sy-Jye Guo
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.627-632
    • /
    • 2005
  • The severe acute respiratory syndrome -SARS virus spreaded rapidly in Asia in 2003 caused a lethal and serious epidemic. Establishing special isolation wards of high-level epidemic prevention has becomes one of the most important tasks of epidemic prevention. Taking the biosafety level of US CDC biology laboratory as an example, the laboratory of the highest level, BL4 and that of the second high level, BL3 are only allowed to handle and research this kind of highly dangerous viruses safely, to ensure the safety of researchers and the surrounding environment.This research aims to study the functions and the design requirements of "special isolation wards", which is equivalent to the high-level biotechnology laboratory, and have an integrated discussion about the design and construction techniques of this kind of wards, expecting to provide a reference for constructing special isolation wards and maintaining operation safely in Taiwan.

  • PDF

호남지역 거점병원 간호사의 신종인플루엔자 감염관리 수행도와 스트레스 (Nurses' Influenza A (H1N1) Infection Control Performance and Stress at Hub Hospitals in Honam Region)

  • 박진희;강정희;김현주
    • 기본간호학회지
    • /
    • 제17권4호
    • /
    • pp.520-530
    • /
    • 2010
  • Purpose: In this study influenza A (H1N1) infection control performance and stress in nurses were surveyed, to identify factors influencing stress for the nurses, and to provide basic materials for promoting infectious disease control by nurses. Method: The participants were 447 nurses who had worked at isolation clinics and/or isolation rooms in hub hospitals in the Honam region during the period of the outbreak of 2009 pandemic influenza A (H1N1) virus. Data were collected in February 2010 using self-report questionnaires. Results: The performance of participants from clinics was high for 'helping patients wearing masks', but low for 'maintaining distance over 1 meter among waiting patients'. The performance of participants from hospital rooms was high for 'putting a surgical mask on a patient going out of the room', but low for 'keeping patients' family out of the room'. The participants' stress was higher in those younger and less experienced nurses, those working at a hospital with 500-999 beds, those working at both isolation clinics and rooms, and those working at a clinic longer. Conclusion: In order to lower nurses' stress from working at isolation clinics/rooms for infectious diseases, we may need to deploy experienced nurses and limit their working days to five or less.

국내 대형병원과 중·소규모 의원의 공기감염 확산 방지 대책의 비교 평가 (Comparative Evaluation of Measures against the Spread of Air-borne Infections in a Large National Hospital and Small and Medium-sized Clinics in Korea)

  • 안지원;양영권;원안나;황정하;박진철
    • 한국생활환경학회지
    • /
    • 제25권1호
    • /
    • pp.90-97
    • /
    • 2018
  • The purpose of this study is to compare and analyze the air infections in middle and small hospitals with the facilities of large national hospitals that have air-borne infection isolation (AII) wards through actual condition investigation and airflow analysis simulation (CFD) and to provide basic data for prevention. The method and scope of the study are as follows. First, through literature review, data related to prevention of infection spread in domestic medical institutions were investigated. Second, we conducted a survey on the status of isolation facilities to prevent the spread of infectious diseases in large hospitals and small and medium - sized clinics in Korea. Third, airflow analysis simulation (CFD) was carried out using the isolation ward of the nationally designated inpatient ward and the data of the plane and facility system of the small clinic. As a result of the study, it is found that regulations applicable to small and medium-sized clinics are insufficient. In addition, the simulation results show that the infectious disease virus is likely to spread to other patients in the hospital.

조혈모세포이식 병동에 관한 문화기술지: 환자를 중심으로 (Ethnography on Isolation Unit for Hematopoietic Stem Cell Transplantation: Focusing on Patients)

  • 강영아;이명선
    • 종양간호연구
    • /
    • 제9권1호
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: The purpose of the study was to understand how patients experience everyday life in an isolation unit for hematopoietic stem cell transplantation (HSCT). Method: The data were collected from 25 patients with HSCT at the isolation unit from January to March in 2008 in one general hospital in Korea. The data were collected by participant observations and ethnographic interviews and were analyzed using ethnographic method. Results: Four themes regarding environmental area emerged: 'barrier pulling up the drawbridge', 'very strange world', 'small and restricted space tied by IV and other treatment lines', and 'loud noise in a silent space.' Three themes regarding patients emerged: 'facing fear and anxiety', 'continuation of loneliness and lethargy', and 'compromising with a very long, dull, and boring time'. These themes describe how patients with HSCT suffer from continuous physical and psychosocial problems in a confined space, while endeavoring to control these problems and to search for hope for a new life. Conclusion: The results of the study provide an in-depth understanding of the experience and culture of patients in an isolation unit for HSCT. They would be used in developing practical programs to decrease patient's culture shock including fear and anxiety at isolation unit for HSCT.

  • PDF

Shigella spp.의 연차적 추이에 관한 조사연구 (A Study on Changing Patterns of Shigella spp. by Years)

  • 신현성;오시환
    • 대한미생물학회지
    • /
    • 제22권4호
    • /
    • pp.453-462
    • /
    • 1987
  • A total of 3,879 cases of feces and rectal swab from patient was collected in H. hospital from January 1974 to December 1986 in Seoul. Among the materials, the number of cases of Shigella spp. isolated were 197 strains of 139 patients. Infectous pattern and antibiotic sensitivity of Shigella spp. were as follows; The range of percentage of an identified Shigella spp. among total feces and rectal swabs was $1.5{\sim}12.5%$ yearly. The isolation ratios of Shigella spp. per each patient 1.35 for male and 1.19 for female. The isolation ratio of male to female was 1.28:1 in whole group. The isolated Shigella species was 81.0% in S. flexneri, 1.1% in S. boydii and 17% in S. sonnei. The highest number of Shigella spp. was found in August and September according to monthly isolation, on the other hand the lowest number of Shigella spp. was obserbed in March. The seasonal isolation rate of Shigella spp. was 31.7% in Fall, 27.3% in Summer, 21.6% in Winter and 19.3% in Spring. The age specific frequency of Shigellosis was 46.8% in $0{\sim}9$ year group, 8.6% in $10{\sim}19$, 7.2% in $40{\sim}49$ and 6.5% in $50{\sim}59$. The antibiotics showing over 80% susceptibility against Shigella spp. were gentamicin, kanamycin, amikacin, tobramycin, cefoperazone, cefoxitin, cefamandole nafate, cefotaxine and sisomycin.

  • PDF

긴급전환형 임시음압격리병실의 기밀도에 따른 최소 급배기 유량차 평가 (Analysis of Minimum Airflow Differences between Supply and Exhaust Air according to Airtightness of Rapidly Converted Temporary Negative Pressure Isolation Rooms)

  • 신희원;김동욱;김지민;정효범;강동화
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권4호
    • /
    • pp.69-77
    • /
    • 2023
  • Purpose: During the COVID-19 pandemic, there have been many cases of converting regular hospital wards into temporary negative pressure isolation wards. The purpose of this study is to evaluate the minimum airflow differences that satisfies the pressure difference criteria(-2.5 Pa) according to airtightness of switching type wards, in preparation for utilization of aging regular wards as negative pressure isolation wards. Methods: Visual inspection and field measurements were conducted using blower door to evaluate airtightness of 5 hospital wards. CONTAM simulation was used to assess the airflow differences when pressure difference between the corridor and wards met the criteria at various levels of airtightness. Results: The ACH50 of evaluated wards ranged from 19.3 to 50.1 h-1 with an average of 37.0 h-1, indicating more than four times leakier than other building types. The minimum airflow differences increased as the airtightness of the wards decreased and the size of the wards increased. Implications: When operating rapidly converted negative pressure isolation wards, understanding airtightness is crucial for determining the minimum airflow differences to maintain the pressure differences. The analysis of this study suggests that improving the airtightness of aging rooms is essential and the minimum airflow differences should be suggested considering both the airtightness and size of rooms.