• Title/Summary/Keyword: Isolation efficiency

Search Result 308, Processing Time 0.026 seconds

Improving Pneumovirus Isolation Using a Centrifugation and AZD1480 Combined Method

  • Lee, Hansaem;Woo, Hye-Min;Kim, Kisoon;Park, Sehee;Park, Man-Seong;Kim, Sung Soon;Kim, You-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.12
    • /
    • pp.2006-2013
    • /
    • 2019
  • The isolation of respiratory viruses, especially from clinical specimens, often shows poor efficiency with classical cell culture methods. The lack of suitable methods to generate virus particles inhibits the development of diagnostic assays, treatments, and vaccines. We compared three inoculation methods, classical cell culture, the addition of a JAK2 inhibitor AZD1480, and centrifugation-enhanced inoculation (CEI), to replicate human respiratory syncytial virus (HRSV) and human metapneumovirus (HMPV). In addition, a combined method using AZD1480 treatment and CEI was used on throat swabs to verify that this method could increase virus isolation efficiency from human clinical specimens. Both CEI and AZD1480 treatment increased HRSV and HMPV genome replication. Also, the combined method using CEI and AZD1480 treatment enhanced virus proliferation synergistically. The combined method is particularly suited for the isolation of interferon-sensitive or slowly growing viruses from human clinical specimens.

Policy evaluation of the rice market isolation system and production adjustment system

  • Dae Young Kwak;Sukho Han
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.629-643
    • /
    • 2023
  • The purpose of this study was to examine the effectiveness and efficiency of a policy by comparing and analyzing the impact of the rice market isolation system and production adjustment system (strategic crops direct payment system that induces the cultivation of other crops instead of rice) on rice supply, rice price, and government's financial expenditure. To achieve this purpose, a rice supply and demand forecasting and policy simulation model was developed in this study using a partial equilibrium model limited to a single item (rice), a dynamic equation model system, and a structural equation system that reflects the casual relationship between variables with economic theory. The rice policy analysis model used a recursive model and not a simultaneous equation model. The policy is distinct from that of previous studies, in which changes in government's policy affected the price of rice during harvest and the lean season before the next harvest, and price changes affected the supply and demand of rice according to the modeling, that is, a more specific policy effect analysis. The analysis showed that the market isolation system increased government's financial expenditure compared to the production adjustment system, suggesting low policy financial efficiency, low policy effectiveness on target, and increased harvest price. In particular, the market isolation system temporarily increased the price during harvest season but decreased the price during the lean season due to an increase in ending stock caused by increased production and government stock. Therefore, a decrease in price during the lean season may decrease annual farm-gate prices, and the reverse seasonal amplitude is expected to intensify.

Modular Photovoltaic PCS with High-frequency Isolation (고주파 절연 모듈형 Photovoltaic PCS)

  • Kwon, Jung-Min;Kwon, Bong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.132-135
    • /
    • 2005
  • A modular photovoltaic PCS with high-frequency isolation is proposed. The proposed system consists of a SEPIC converter and a full-bridge inverter. Using the power slope versus voltage of the PV array, the MPPT controller is proposed that produces a smooth transition to the maximum power point. The disturbance of the line voltage is detected using a fast sensing technique. Experimental results obtained on a 500W prototype show high performance such as almost unity power factor, $90\%$ power efficiency, $3.6\%$ THD.

  • PDF

Seismic Nonlinear Damage Assessment and Retrofit Strategies for Existing Bridges with Isolation System using Retrofit Slate Function (비선형 내진 손상도 평가 및 보강상태함수를 이용한 기존교량의 내진 보강 전략)

  • Cho, Hyo-Nam;Choi, Hyun-Ho;Eom, Won-Seok;Shin, Man-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.179-191
    • /
    • 2002
  • This paper presents a systematic approach to the seismic nonlinear analysis and retrofit strategies for existing bridges with isolation system using retrofit slate function newly proposed in this study. A seismic retrofit scheme using sliding base isolation system was presented to reduce the seismic hazard for bridge structures. In this study, two types of isolation systems such as lead bearings and sliding isolators were used. The behavior of sliding isolators was modeled by a triaxial interaction model. And three types of earthquakes such as El Centro, San Fernando, and the artificial were used as earthquake ground excitations. Seismic response analyses of the bridge before and after retrofit were effectively carried out by using a three-dimensional nonlinear seismic analysis program, IDARC-Bridge. Also, this paper proposes a retrofit state function for easily representing the efficiency of a retrofit scheme.

Analysis, Design, Modeling, Simulation and Development of Single-Switch AC-DC Converters for Power Factor and Efficiency Improvement

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2008
  • This paper addresses several issues concerning the analysis, design, modeling, simulation and development of single-phase, single-switch, power factor corrected AC-DC high frequency switching converter topologies with transformer isolation. A detailed analysis and design is presented for single-switch topologies, namely forward buck, flyback, Cuk, Sepic and Zeta buck-boost converters, with high frequency isolation for discontinuous conduction modes (DCM) of operation. With an awareness of modem design trends towards improved performance, these switching converters are designed for low power rating and low output voltage, typically 20.25W with 13.5V in DCM operation. Laboratory prototypes of the proposed single-switch converters in DCM operation are developed and test results are presented to validate the proposed design and developed model of the system.

Numerical Study on Load Transfer Efficiency of Floating Slab Track (플로팅궤도 연결부의 하중전달효율 산정을 위한 수치해석)

  • Chung, Won-Seok;Jang, Hoon;Park, Sung-Jae;Park, Myung-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1287-1292
    • /
    • 2010
  • Recently, many railway stations are built under the railway line in urban area. The passage of railway vehicles generates mechanical vibrations of a wide range of frequency. Thus, it is required to place structural vibration isolation systems to reduce vibration and noise originating from surrounding environments. This study utilizes elastometric bearings as a vibration isolation system. The slab track system on elastometric bearings is called "low vibration track" or "floating slab track." In this low vibration track system, dowel bars or plates can be installed to minimize the discontinuity of displacement between adjacent floating slab tracks. This study is to numerically investigate the effects of dowel members on static behavior of the low vibration track. The study involves two steel dowel systems including dowel bars and dowel plates. Each dowel system is analyzed under the service load condition to assess load transfer efficiency (LTE).

  • PDF

Investigation of the effects of common and separate ground systems in wireless power transfer

  • Park, Woocheon;Moon, Jung-Ick;Cho, In-kui
    • ETRI Journal
    • /
    • v.44 no.2
    • /
    • pp.339-345
    • /
    • 2022
  • This article presents an investigation of the effects on a grounding system of wireless power transfer (WPT) when transmitting over relatively far distances, that is, up to 1.25 m. Conventional two-coil WPT systems are sufficiently commercialized in strong coupling range, but it is important to accomplish the long-range WPT in weak coupling range for further various applications. This system depends on the coupling effect between the two coils that the grounds of the transmitting and receiving coils should be completely separated. However, when evaluating the performance of two-coil systems with the instrument consisting of two ports and one common ground, undesirable problems occur in weak coupling ranges, for example, obtaining disagreeable transmission efficiency and degrading system stability/reliability. We investigate the problems of the leakage power from common ground systems and provide a practical solution to obtain a reliable WPT system by using an isolation transformer. The usefulness of this approach is that it is possible to achieve the stability of the system with relatively far transmitting distances and to determine the exact transmission efficiency.

The Effect that Empathic Value Expectation of Culture & Art Education and Social Intention have on Eliminating Controlled Mechanism (문화예술교육 공감기대가치와 사회적 성향이 통제된 기제 해소에 미치는 영향)

  • Kim, Chul-Ho
    • Journal of Digital Convergence
    • /
    • v.15 no.4
    • /
    • pp.427-441
    • /
    • 2017
  • The purpose of this research is to examine the effect EVE about culture & art education and social tendencies have on adult educatees eliminating controlled mechanisms. Quantitative research on those in their 40s and 50s was executed. The results show that there is a high correlation between GEVE and individualism, REVE and collectivism. GEVE has a higher influence on actualization of self-efficiency, FEVE on reignition of retained desires, REVE on substantialization of non-isolation, individualism on actualization of self-efficiency, and collectivism on substantialization of non-isolation. This research evokes the importance of an interdisciplinary and integrated understanding of EVE in culture & art education, educatees' social tendencies, and their psychological mechanisms. Also, it suggests the necessity of following research and practical adaptation related to developing programs, securing quantitative and qualitative appropriateness reflecting social requirements, and operation, evaluation, and management considering reciprocality.

Isolation and Growth Characteristics of Alkalophilic Bacillus sp. for Removal of Anthraquinone Dye. (Anthraquinone계 염료의 제거를 위한 호알칼리성 Bacillus sp.의 분리와 성장 특성)

  • 김정목
    • Microbiology and Biotechnology Letters
    • /
    • v.29 no.2
    • /
    • pp.67-71
    • /
    • 2001
  • Isolation and Growth Characteristics of AIkalophilic Bacillus sp. for Removal of Anthraquinone Dye. Kim, Jeong-Mog. School of Environmental Information, Taekyeung College, Kyungsan, 712-850, Korea -Alkalophilic strain degrading and decolorizing anthraquinone dye, Remazol brilliant blue R was isolated from natural system and named as Bacillus sp. ARB!. The optimal temperature and pH of Bacillus sp. ARBI were 35°C and 9.0, respectively. The pH of culture media during the fermentation were changed from 10 and 10.5 of initial values to 9.3 and 9.4 after 40 hrs, respectively. Decolorization efficiency in aerobic shaking culture of Bacillus sp. ARBI was markedly higher than that in standing culture. At the optimal culture condition, decolorization efficiency by the Bacillus sp. ARBl was 93% after 32 hrs batch culture. In the case of batch culture using real dye processing wastewater, dye decolorization efficiency of Bacillus sp. ARBl was 78% after 40 hrs.

  • PDF

A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation (절연형 고효율 PFC AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Roan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.