• Title/Summary/Keyword: Isolation System

Search Result 1,761, Processing Time 0.034 seconds

Assessment of a dual isolation system with base and vertical isolation of the upper portion

  • Sasan Babaei;Panam Zarfam;Abdolreza Sarvghad Moghadam;Seyed Mehdi Zahrai
    • Structural Engineering and Mechanics
    • /
    • v.88 no.3
    • /
    • pp.263-271
    • /
    • 2023
  • Base isolation is a widely used technique for the seismic control of structures as it reduces the structural seismic demand. However, displacement of the isolation layer is not economically feasible in congested urban areas. To resolve the issue, an innovative system is proposed here to isolate both horizontally at the base and vertically in the upper portion of the structure. A simplified linear three degree-of-freedom (3DOF) model of the system that considers the mass and stiffness ratios of the substructure has been introduced and analyzed in MATLAB by spectrum analysis. The 3DOF model results revealed that, when the period of the soft substructure reaches 2.5 times that of the stiff substructure, the isolation and the lower substructure responses decrease by 65% and 51%, respectively. Time-history analysis of a MDOF system at three frequency ratios under a wide range of ground motions indicated that, at the expense of accepting a certain large drift by the soft substructure in the upper portion of the structure, base isolation displacement can be decreased by 10%.

Evaluation of Performance of the Teflon-Type Seismic Foundation Isolation System (테프론형 기초지진격리장치의 성능평가)

  • Son, Su Won;Kim, Eung Soo;Na, Geon Ha;Kim, Jin Man
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.125-135
    • /
    • 2017
  • Various seismic isolation methods are being applied to bridges and buildings to improve their seismic performance. Most seismic isolation systems are the structural seismic isolation systems. In this study, the seismic performance of geotechnical seismic isolation system capable of isolating the lower foundation of the bridge structure from ground was evaluated. The geotechnical seismic isolation system was built with teflon, and the model structure was made by adopting the similitude law. The response acceleration for sinusoidal waves of various amplitudes and frequencies and seismic waves were analyzed by performing 1-G shaking table experiments. Fixed foundation, Sliding foundation, and Rocking foundation were evaluated. The results of this study indicated that the Teflon-type seismic foundation isolation system is effective in reducing the acceleration transmitted to the superstructure subject to large input ground motion. Response spectrum of the Rocking and Sliding foundation structures moves to the long period, while that of Fixed foundation moves to short period.

Performance Evaluation of IRB System Using Seismic Isolation Test (내진시험을 통한 IRB 시스템의 성능 평가)

  • Park, Young-Gee;Ha, Sung Hoon;Woo, Jae Kwan;Choi, Seung-Bok;Kim, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.401-406
    • /
    • 2013
  • This paper presents experimental evaluation of IRE (isolation roller bearing) seismic isolation device. From the combination of base isolation on the IRE system displacement response spectrum and acceleration response spectrum, the compressive strength and the coefficient of friction experiments. Also the IRE system is evaluated by environment test according to KS standards. Both the resonance and seismic experiments using a combination of the IRE and Natural Rubber Bearing (NRB) are performed in order to analyze the seismic isolation of the IRE system dynamic characteristics. For the given load and exciting frequency, the resonant frequency becomes lower, but the resonant magnification remains to be same. However, it is shown that when we consider the IRE only, the vibration on the table with the horizontal movement and the independent horizontal displacement due to the rolling motion of the plate and roller are significantly reduced. This result verifies that the proposed optimal design method of the IRE system is very effective.

  • PDF

EFFECTS OF MECHANICAL PROPERTY VARIABILITY IN LEAD RUBBER BEARINGS ON THE RESPONSE OF SEISMIC ISOLATION SYSTEM FOR DIFFERENT GROUND MOTIONS

  • Choun, Young-sun;Park, Junhee;Choi, In-Kil
    • Nuclear Engineering and Technology
    • /
    • v.46 no.5
    • /
    • pp.605-618
    • /
    • 2014
  • The effects of variability of the mechanical properties of lead rubber bearings on the response of a seismic isolation system are investigated. Material variability in manufacturing, aging, and operation temperature is assumed, and two variation models of an isolation system are considered. To evaluate the effect of ground motion characteristics on the response, 27 earthquake record sets with different peak A/V ratios were selected, and three components of ground motions were used for a seismic response analysis. The response in an isolation system and a superstructure increases significantly for ground motions with low A/V ratios. The variation in the mechanical properties of isolators results in a significant influence on the shear strains of the isolators and the acceleration response of the superstructure. The variation provisions in the ASCE-4 are reasonable, but more strict variation limits should be given to isolation systems subjected to ground motions having low A/V ratios. For application of seismic isolation systems to safety-related nuclear structures, the variation in the material and mechanical properties of the isolation system should be properly controlled during the manufacturing and aging processes. In addition, special consideration should be given to minimize the accidental torsion caused by the dissimilarity in the stiffness variations of the isolators.

Modeling and Control of a Four Mount Active Micro-vibration Isolation System

  • Banik, Rahul;Gweon, Dae-Gab;Hong, Dong-Pyo
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.150-153
    • /
    • 2006
  • Micro vibration isolation, typically originated from ground, is always a prime concern for the nano-measurement instruments such as Atomic Force Microscopes. A four mount active vibration isolation system is proposed in this paper. Modeling and control of such a four mount system as analyzed. Combined active-passive isolation principle is used for vibration isolation by mounting the instrument on a passively damped isolation system made of Elastomer along with the active stage in parallel that consists of very soft actuation system, the Voice Coil Motor. The active stage works in combination with the passive stage for working as a very low frequency vibration attenuator.

  • PDF

Development of the Optimal Design Technique for the Pneumatic Vibration Isolation System by Nonlinear Modeling and Analysis (공압방진시스템의 비선형 모델링과 해석을 통한 최적설계기술 개발)

  • 문준희;박희재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.151-154
    • /
    • 2001
  • The pneumatic vibration isolation systems have been widely used in industry and laboratories, but the full mathematical analysis and nonlinear modeling techniques have not been reported yet, even while the nonlinear features of the pneumatic vibration isolation system decide the main characteristics. For instance, the orifice in a pneumatic vibration isolator has been traditionally considered as a simple viscous damper, which was too much simplified to explain the performance of the isolation system. In this paper, the nonlinear characteristics are considered for the orifice and chamber, etc. The numerical simulation is carried out by the MATLAB/Simulink software. From the analysis result, a clear trend of the nonlinear features is shown: the vibration transmissibility changes not only due to the excitation frequency but also due to the amplitude of the vibration excitation. Therefore various design parameters are optimally chosen for the vibration isolation system. The proposed methods show good compatibility between the analysis results and the experiments.

  • PDF

Vibration control of the vibration isolation system using the electromagnetic actuator (전자석 액츄에이터에 의한 수동방진 테이블의 제어)

  • Choi, Hyun;Lee, Jung-Youn
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.227-232
    • /
    • 2003
  • As the most precision equipment requiring very strict vibration environment are vulnerable to the surrounding vibration condition, they adapt the passive or active vibration isolation system. When it comes to the passive isolation system, the resonance of the isolation system causes excessive resonance response, and finally results in the degrade the equipment performance. This paper deals with the active control method to control this resonance induced response, and includes the experiment on the active control for controlling the resonance response on the table against the excitation of the same frequency with the natural frequency of the isolation system. The electromagnetic actuator was designed and the control effect was verified by the experiment. The experiment showed that the electromagnetic actuator is effective for controlling the low frequency isolation resonance response of the precision equipment.

  • PDF

A Comparative Study on Aseimatic Performances of Various Base Isolation Systems (여러 가지 기초분리 장치의 내진성능에 관한 비교연구)

  • 박규식
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.236-243
    • /
    • 1999
  • A comparative study on aseismatic performances of various base isolation systems for the multi-span continuous bridge is carried out. Several leading base isolation systems the LRB system the RF system the R-FBI system and the EDF system are considered, The displacement of the deck the deformation of the upper ends of the piers the shear force and the bending moment of the lower ends of the piers are obtained by using the accelerograms of the N00W component of El Centro earthquake(1940) and the N90W component of Mexico City earthquake(1985) Nonlinear time-history analysis is carried out. comparisons of the results with the conventional bearing show that the base isolation systems are very effective in reducing the forces transmitted to the superstructures. Furthermore the results also show that the friction-type base isolation systems are less sensitive to unexpected variations in frequency content of the ground acceleration. The R-FBI system shows a good aseismatic performance comparing with other base isolation systems.

  • PDF

Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation

  • Jiang, Guoping;Tao, Weijun
    • Structural Engineering and Mechanics
    • /
    • v.51 no.4
    • /
    • pp.643-650
    • /
    • 2014
  • A chaotic vibration isolation system is designed according to the chaotic vibration theory in this paper. The strong nonlinearity is generated by the system. Line spectra in the radiated noise maybe easily detected caused by marine vessels. It is Important to reduce the line spectra by improving the acoustic stealth of marine vessels. A multi-degree-freedom (MDF) nonlinear vibration isolation system (NVIS) system is setup by the experiment and finite element method. The model is established with finite element method. The results show that the behavior of the device gradually varies from period bifurcation into chaotic state and the line spectrum is changed from single spectral structure into broadband spectral structure. It is concluded that chaotic vibration isolation is preferable contrasted on line spectra isolation.

Dynamic Characteristics and Isolation Performance of Isolation Table System (면진 테이블 시스템의 동적 특성 및 면진성능)

  • ;;;Kurabayashi
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.67-74
    • /
    • 2001
  • Structural engineers lately have an interest in the safety for equipments and facility in buildings subjected to earthquake. The stability of cultural assets was not considered for the earthquake induced vibration, while the integrity of structure has been considered through the resistant earthquake design. The purpose of this study aimed to analyze the behavior of isolation device named as \"Isolation table system\" and to evaluate its isolation performance through the experiment study. Isolation table is one of isolation systems to reduce the vibration which was transferred from slab to exhibition table. Experimental result shows that isolation table can reduce the vibration by 80-90% and its behavior is very stable within its maximal stroke.al stroke.

  • PDF