• 제목/요약/키워드: Isolation Improvement

검색결과 253건 처리시간 0.027초

확장 패리티 공간 기법의 이중고장 검출성능 향상 연구 (Improvement of the Double Fault Detection Performance of Extended Parity Space Approach)

  • 이원희;박찬국;이달호;김광훈
    • 제어로봇시스템학회논문지
    • /
    • 제15권10호
    • /
    • pp.1002-1008
    • /
    • 2009
  • We consider a double faults detection and isolation problem using modified extended parity space approach for inertial measurement unit which use redundant inertial sensors. A redundant IMU which has a hardware redundant is composed of the cone shape because it is good for fault detection and isolation. We analyze the type of double faults and the reason why fault isolation performance is low. We propose modified extended parity space approach method using EPSA and the difference of sensor data.

화학사고의 일차 대응을 위한 피해영향범위 산정 개선 방안 (Improvement of Damage Range Calculation for First Response to Chemical Accidents)

  • 이덕재;안재현;송창근
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.59-65
    • /
    • 2017
  • Calculation of the damage impact of chemical accidents is an important element in site, and the initial isolation distance and the protective action distances are significant factors in coping the chemical accident. In this study, three major cities that represent each Province were selected, and the safety distances were calculated considering regional climate conditions. The results were compared with the prescribed values in Emergency Response Guidebook. It is concluded that the regional meteorological conditions such as temperature, vapour pressure, relative humidity, wind speed, and cloud cover should be reflected in estimating the initial isolation distance and the protective action distance.

퍼지논리를 이용한 다중관측자 구조 FDIS의 성능개선 (Performance Improvement of MOS type FDIS using Fuzzy Logic)

  • 류지수;박태건;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.410-413
    • /
    • 1998
  • A passive approach for enhancing fault detection and isolation performance of multiple observer based fault detection isolation schemes(FDIS) is proposed. The FDIS has a hierarchical framework to perform detection and isolation of faults of interest, and diagnosis of process faults. The decision unit comprises of a rule base and fuzzy inference engine and removes some difficulties of conventional decision unit which includes crisp logic and threshold values. Emphasis is placed on the design and evaluation methods of the diagnostic rule base. The suggested scheme is applied for the FDIS design for a DC motor driven centrifugal pump system.

  • PDF

Small Internal Antenna Using Multiband, Wideband, and High-Isolation MIMO Techniques

  • Kim, Sang-Hyeong;Jin, Zhe-Jun;Chae, Yoon-Byung;Yun, Tae-Yeoul
    • ETRI Journal
    • /
    • 제35권1호
    • /
    • pp.51-57
    • /
    • 2013
  • In this paper, a small internal antenna for a mobile handset is presented using multiband, wideband, and high-isolation multiple-input multiple-output techniques. The proposed antenna consists of three planar inverted-F antennas (PIFAs) that operate in the global system for mobile communication (GSM900), the digital communication system (DCS), the personal communication system (PCS), the universal mobile telecommunication system (UMTS), and wireless local area network (WLAN) bands with a physical size of $40mm{\times}10mm{\times}10mm$. A resonator attached to the folded PIFA creates dual resonances, achieving a wide bandwidth of approximately 460 MHz, covering the DCS, PCS, and UMTS bands; a meander shorting line is used to improve impedance matching. Additionally, a modified neutralization link is embedded between diversity antennas to enhance isolation, which results in a 6-dB improvement in the isolation and less than 0.1 in the envelope correlation coefficient evaluated from the far-field radiation patterns. Simulation and measurements demonstrate very similar results for S-parameters and radiation patterns. Peak gains show 3.73 dBi, 3.77 dBi, 3.28 dBi, 2.15 dBi, and 5.86 dBi, and antenna efficiencies show 56.15%, 72.15%, 68.59%, 52.92%, and 82.93% for GSM900, DCS, PCS, UMTS, and WLAN bands, respectively.

퍼지기법에 기초한 로드분배 방식에 의한 웹서버 성능향상 (A Fuzzy Technique-based Web Server Performance Improvement Using a Load Balancing Mechanism)

  • 박범주;박기진;강명구;김성수
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제35권3호
    • /
    • pp.111-119
    • /
    • 2008
  • 본 논문에서는 차별화 서비스를 지원하는 웹 서버의 응답시간 성능을 향상시키기 위해 기존의 동적 성능 분리 기법에 퍼지 기법을 접목한다. 특히, 클러스터 기반 웹서버 시스템의 부하량에 대한 판단 기준 흑은 사용자 요청율 및 동적요청 비율 변화시에 발생하는 애매모호한 상황을 효과적으로 반영하기 위해, 퍼지제어 기법에 기초한 로드분배 메커니즘을 제안하였다. 이를 통해, 기존의 퍼지 기법을 활용하지 않은 성능분리 기법과 퍼지기법을 활용한 경우에 대해 응답시간(95-percentile of Response Time) 성능비교 평가를 통해 퍼지기반의 성능분리 기법이 차별화 서비스 시스템의 성능을 더욱 강건하고 효율적으로 향상시킬 수 있다는 점을 검증하였다.

Rapid Isolation of Genomic DNA from Normal and Apoptotic Cells Using Magnetic Silica Resins

  • Park, Jee-Sun;Park, Jung-Hyun;Na, Shin-Young;Choe, Soo-Young;Choi, Sang-Nam;You, Kwan-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권5호
    • /
    • pp.890-894
    • /
    • 2001
  • The isolation of genomic DNA from mammalian cells is usually performed by cell lysis followed by protein digestion, extraction, and finally, ethanol precipitation of the chromosomal DNA. However, in the case of large sample numbers or when only small amounts of starting materials are available, such conventional methods are not efficient and are cumbersome to be applied. Some alternative methods have been described as well as having commercial DNA isolation kits to be available, nevertheless, there is room left for much improvement. In the present study, a novel method is introduced, where it simplifies conventional protocols by omitting some time-consuming steps such as protease incubation or DNA precipitation and its resuspension. Using paramagnetic silica resins, the genomic DNA was purified over a magnetic field, and the bound DNA was eluted with a low-salt buffer. The fidelity and effectiveness of this novel method was determined by using normal and apoptotic cells as a starting material and then compared to other protocols. The high speed and convenience along with its high efficiency in detecting apoptotic chromosomal DNA will prove this method to be an improved alternative in the isolation of genomic DNA from mammalian cells.

  • PDF

노치 필터 제어기법을 이용한 반작용 휠 미소진동 절연장치의 절연성능 평가 (Performance Evaluation of RWA Vibration Isolator Using Notch Filter Control)

  • 박지용;서종은;이대은;한재흥
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.391-397
    • /
    • 2016
  • Vibration disturbances induced by the reaction wheels can severely degrade the performance of high precision payloads on board satellites with high pointing stability requirements. The unwanted disturbances produced by the reaction wheels are composed of fundamental harmonic disturbances due to the flywheel imbalance and sub/higher harmonic disturbances due to bearing irregularities, motor imperfections and so on. Because the wheel speed is constantly changed during the operation of a reaction wheel, the vibration disturbance induced by the reaction wheels can magnify the satellite vibration when the rotating frequency of wheel meets the natural frequency of satellite structure. In order to provide an effective isolation of the reaction wheel disturbances, isolation performance of a hybrid vibration isolator is investigated. In this paper, hybrid vibration isolator that combines passive and active components is developed and its hybrid isolation performance using notch filter control is evaluated in single-axis. The hybrid isolation performance using notch filter control show additional performance improvement compared to the results using only passive components.

마찰복원형 지진격리장치가 설치된 케이블교량의 성능 기반 내진설계법 개선(II-내진설계 절차 제안) (Improvement of the Performance Based Seismic Design Method of Cable Supported Bridges with Resilient-Friction Base Isolation Systems (II-Proposal for the Seismic Design Procedure))

  • 길흥배;박선규;한경봉;윤완석
    • 한국지진공학회논문집
    • /
    • 제24권4호
    • /
    • pp.169-178
    • /
    • 2020
  • In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the "Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges" is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.

면진된 모형 비상디젤발전기의 지진응답 실험 (Shaking Table Test of Isolated EDG Model)

  • 김민규;전영선
    • 한국지진공학회논문집
    • /
    • 제11권3호
    • /
    • pp.33-42
    • /
    • 2007
  • 본 연구에서는 원전내 주요 안전관련 기기중 비상디젤발전기를 대상으로 한 진동대 실험을수행하였다. 원전의 비상디젤 발전기는 원전 전체의 노심손상빈도에 미치는 영향이 매우 크며 또한 면진장치를 설치하여 지진력을 저감시킬 경우 큰 폭으로 노심손상빈도를 감소시킬 수 있으며, 가동중 발생하는 소음과 진동으로 인하여 주변 구조물과 기기에 영향을 미치기도 한다. 따라서 지진력 저감과 기계 진동의 저감효과를 동시에 고려하기 위한 면진장치를 적용하여 그 효과를 평가하여 보고자하였다. 면진장치로는 코일스프링과 점성 댐퍼가 결합된 형태의 면진장치를 선정하였다. 실험의 대상으로 하는 비상디젤발전기는 영광 5,6호기에 설치되어 있는 모델로서 축소모형을 제작하였으며, 제작된 모형에 적합한 코일스프링-점성댐퍼 시스템을 설계하여 제작하였다. 제작된 면진장치를 축소모형에 설치하여 설계지진을 이용한 진동대 시험을 수행하여 지진력 저감효과를 분석하였다 본 연구를 통하여 설계지진의 경우 20% 그리고 Scenario 지진의 경우 70% 까지의 지진력 저감이 가능한 것을 확인하였으며, 면진장치의 기계적 특성이 설계값과 일치하지 않음으로 인하여 실제 지진력 저감효과가 크게 변할 수 있음을 확인할 수 있었다.

New approach in design of seismic isolated buildings applying clusters of rubber bearings in isolation systems

  • Melkumyan, Mikayel G.
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.587-606
    • /
    • 2013
  • The given paper presents a new approach in design of seismic isolation systems of base isolated buildings. The idea is to install not one big size rubber bearing under the columns and/or shear walls, or one by one with certain spacing under the load-bearing walls, but to install a group/cluster of small size bearings, in order to increase the overall effectiveness of the isolation system. The advantages of this approach are listed and illustrated by the examples. Also the results of analyses of some buildings where the approach on installation of clusters of rubber bearings was used in their isolation systems are given for two cases: i) when the analyses are carried out based on the provisions of the Armenian Seismic Code, and ii) when the time history analyses are carried out. Obtained results are compared and discussed. Paper also presents, as an example, detailed analysis and design of the 18-story unique building in one of the residential complexes in Yerevan. Earthquake response analyses of this building were carried out in two versions, i.e. when the building is base isolated and when it is fixed base. Several time histories were used in the analyses. Comparison of the obtained results indicates the high effectiveness of the proposed structural concepts of isolation systems and the need for further improvement of the Seismic Code provisions regarding the values of the reduction factors. A separate section in the paper dedicated to the design of high damping laminated rubber-steel bearings and to results of their tests.