• Title/Summary/Keyword: Isolation Improvement

Search Result 253, Processing Time 0.026 seconds

Improvement of the Double Fault Detection Performance of Extended Parity Space Approach (확장 패리티 공간 기법의 이중고장 검출성능 향상 연구)

  • Lee, Won-Hee;Park, Chan-Gook;Lee, Dal-Ho;Kim, Kwang-Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.10
    • /
    • pp.1002-1008
    • /
    • 2009
  • We consider a double faults detection and isolation problem using modified extended parity space approach for inertial measurement unit which use redundant inertial sensors. A redundant IMU which has a hardware redundant is composed of the cone shape because it is good for fault detection and isolation. We analyze the type of double faults and the reason why fault isolation performance is low. We propose modified extended parity space approach method using EPSA and the difference of sensor data.

Improvement of Damage Range Calculation for First Response to Chemical Accidents (화학사고의 일차 대응을 위한 피해영향범위 산정 개선 방안)

  • Lee, Deok Jae;Ahn, Jae-Hyun;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • Calculation of the damage impact of chemical accidents is an important element in site, and the initial isolation distance and the protective action distances are significant factors in coping the chemical accident. In this study, three major cities that represent each Province were selected, and the safety distances were calculated considering regional climate conditions. The results were compared with the prescribed values in Emergency Response Guidebook. It is concluded that the regional meteorological conditions such as temperature, vapour pressure, relative humidity, wind speed, and cloud cover should be reflected in estimating the initial isolation distance and the protective action distance.

Performance Improvement of MOS type FDIS using Fuzzy Logic (퍼지논리를 이용한 다중관측자 구조 FDIS의 성능개선)

  • Ryu, Ji-Su;Park, Tae-Geon;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.410-413
    • /
    • 1998
  • A passive approach for enhancing fault detection and isolation performance of multiple observer based fault detection isolation schemes(FDIS) is proposed. The FDIS has a hierarchical framework to perform detection and isolation of faults of interest, and diagnosis of process faults. The decision unit comprises of a rule base and fuzzy inference engine and removes some difficulties of conventional decision unit which includes crisp logic and threshold values. Emphasis is placed on the design and evaluation methods of the diagnostic rule base. The suggested scheme is applied for the FDIS design for a DC motor driven centrifugal pump system.

  • PDF

Small Internal Antenna Using Multiband, Wideband, and High-Isolation MIMO Techniques

  • Kim, Sang-Hyeong;Jin, Zhe-Jun;Chae, Yoon-Byung;Yun, Tae-Yeoul
    • ETRI Journal
    • /
    • v.35 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • In this paper, a small internal antenna for a mobile handset is presented using multiband, wideband, and high-isolation multiple-input multiple-output techniques. The proposed antenna consists of three planar inverted-F antennas (PIFAs) that operate in the global system for mobile communication (GSM900), the digital communication system (DCS), the personal communication system (PCS), the universal mobile telecommunication system (UMTS), and wireless local area network (WLAN) bands with a physical size of $40mm{\times}10mm{\times}10mm$. A resonator attached to the folded PIFA creates dual resonances, achieving a wide bandwidth of approximately 460 MHz, covering the DCS, PCS, and UMTS bands; a meander shorting line is used to improve impedance matching. Additionally, a modified neutralization link is embedded between diversity antennas to enhance isolation, which results in a 6-dB improvement in the isolation and less than 0.1 in the envelope correlation coefficient evaluated from the far-field radiation patterns. Simulation and measurements demonstrate very similar results for S-parameters and radiation patterns. Peak gains show 3.73 dBi, 3.77 dBi, 3.28 dBi, 2.15 dBi, and 5.86 dBi, and antenna efficiencies show 56.15%, 72.15%, 68.59%, 52.92%, and 82.93% for GSM900, DCS, PCS, UMTS, and WLAN bands, respectively.

A Fuzzy Technique-based Web Server Performance Improvement Using a Load Balancing Mechanism (퍼지기법에 기초한 로드분배 방식에 의한 웹서버 성능향상)

  • Park, Bum-Joo;Park, Kie-Jin;Kang, Myeong-Koo;Kim, Sung-Soo
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.3
    • /
    • pp.111-119
    • /
    • 2008
  • This paper combines fuzzy concepts with an existing dynamic performance isolation technique in order to improve the response time performance of a Web server supporting differentiated services. A load balancing mechanism based on the fuzzy control technique is developed in such a way that ambiguous situations caused by workload estimation of cluster-based Web servers, client request rates, and dynamic request rates can be represented in an effective way. In addition, we verify that the fuzzy-based performance isolation technique improves the performance and robustness of differentiated service systems efficiently through comparing 95-percentile of response time between the fuzzy-based Performance isolation technique and the existing one, which do not use the fuzzy concept.

Rapid Isolation of Genomic DNA from Normal and Apoptotic Cells Using Magnetic Silica Resins

  • Park, Jee-Sun;Park, Jung-Hyun;Na, Shin-Young;Choe, Soo-Young;Choi, Sang-Nam;You, Kwan-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.5
    • /
    • pp.890-894
    • /
    • 2001
  • The isolation of genomic DNA from mammalian cells is usually performed by cell lysis followed by protein digestion, extraction, and finally, ethanol precipitation of the chromosomal DNA. However, in the case of large sample numbers or when only small amounts of starting materials are available, such conventional methods are not efficient and are cumbersome to be applied. Some alternative methods have been described as well as having commercial DNA isolation kits to be available, nevertheless, there is room left for much improvement. In the present study, a novel method is introduced, where it simplifies conventional protocols by omitting some time-consuming steps such as protease incubation or DNA precipitation and its resuspension. Using paramagnetic silica resins, the genomic DNA was purified over a magnetic field, and the bound DNA was eluted with a low-salt buffer. The fidelity and effectiveness of this novel method was determined by using normal and apoptotic cells as a starting material and then compared to other protocols. The high speed and convenience along with its high efficiency in detecting apoptotic chromosomal DNA will prove this method to be an improved alternative in the isolation of genomic DNA from mammalian cells.

  • PDF

Performance Evaluation of RWA Vibration Isolator Using Notch Filter Control (노치 필터 제어기법을 이용한 반작용 휠 미소진동 절연장치의 절연성능 평가)

  • Park, Geeyong;Suh, Jong-Eun;Lee, Dae-Oen;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.391-397
    • /
    • 2016
  • Vibration disturbances induced by the reaction wheels can severely degrade the performance of high precision payloads on board satellites with high pointing stability requirements. The unwanted disturbances produced by the reaction wheels are composed of fundamental harmonic disturbances due to the flywheel imbalance and sub/higher harmonic disturbances due to bearing irregularities, motor imperfections and so on. Because the wheel speed is constantly changed during the operation of a reaction wheel, the vibration disturbance induced by the reaction wheels can magnify the satellite vibration when the rotating frequency of wheel meets the natural frequency of satellite structure. In order to provide an effective isolation of the reaction wheel disturbances, isolation performance of a hybrid vibration isolator is investigated. In this paper, hybrid vibration isolator that combines passive and active components is developed and its hybrid isolation performance using notch filter control is evaluated in single-axis. The hybrid isolation performance using notch filter control show additional performance improvement compared to the results using only passive components.

Improvement of the Performance Based Seismic Design Method of Cable Supported Bridges with Resilient-Friction Base Isolation Systems (II-Proposal for the Seismic Design Procedure) (마찰복원형 지진격리장치가 설치된 케이블교량의 성능 기반 내진설계법 개선(II-내진설계 절차 제안))

  • Gil, Heungbae;Park, Sun Kyu;Han, Kyoung Bong;Yoon, Wan Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.169-178
    • /
    • 2020
  • In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the "Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges" is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.

Shaking Table Test of Isolated EDG Model (면진된 모형 비상디젤발전기의 지진응답 실험)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.33-42
    • /
    • 2007
  • In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

New approach in design of seismic isolated buildings applying clusters of rubber bearings in isolation systems

  • Melkumyan, Mikayel G.
    • Earthquakes and Structures
    • /
    • v.4 no.6
    • /
    • pp.587-606
    • /
    • 2013
  • The given paper presents a new approach in design of seismic isolation systems of base isolated buildings. The idea is to install not one big size rubber bearing under the columns and/or shear walls, or one by one with certain spacing under the load-bearing walls, but to install a group/cluster of small size bearings, in order to increase the overall effectiveness of the isolation system. The advantages of this approach are listed and illustrated by the examples. Also the results of analyses of some buildings where the approach on installation of clusters of rubber bearings was used in their isolation systems are given for two cases: i) when the analyses are carried out based on the provisions of the Armenian Seismic Code, and ii) when the time history analyses are carried out. Obtained results are compared and discussed. Paper also presents, as an example, detailed analysis and design of the 18-story unique building in one of the residential complexes in Yerevan. Earthquake response analyses of this building were carried out in two versions, i.e. when the building is base isolated and when it is fixed base. Several time histories were used in the analyses. Comparison of the obtained results indicates the high effectiveness of the proposed structural concepts of isolation systems and the need for further improvement of the Seismic Code provisions regarding the values of the reduction factors. A separate section in the paper dedicated to the design of high damping laminated rubber-steel bearings and to results of their tests.