• Title/Summary/Keyword: Isolated building

Search Result 232, Processing Time 0.028 seconds

Studies on the Improvement of Privately Owned Public Space for the Betterment of Urban Streetscape (도시 가로 환경 향상을 위한 공개공지 개선방안)

  • Park, J.L.;Kwon, Y.H.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.15 no.1
    • /
    • pp.107-121
    • /
    • 2013
  • This study was developed to investigate the effects of privately owned public space (POPS) on urban streetscape and to find ways to prevent the discontinuation of street continuity on urban landscape when creating POPS in urban space and the surrounding streets. Several case studies and policies and laws related to POPS were reviewed to identify the practical problems as well as current state. An additional analysis was conducted on the different types of POPS to examine spatial connections between them and streetscapes and to find ways to improve POPS on urban streetscape. Our results show that POPS surrounding a building (i.e. frontage space and adjacent sidewalks) should be considered as one space in the integrated perspective. In addition, the type of facilities installed on POPS would be decided according to whether POPS is recognized as the part of public rest area or treated as the part of street. The results of the study will serve as useful data to solve the current problems with city's POPS, which destroys spatial continuity by focusing on increasing the number of POPS and creates high-rise buildings isolated from existing spaces. This study will also contribute to improve the quality of future POPS.

Seismic Performance Evaluation of Multi-Story Piping Systems using Triple Friction Pendulum Bearing (지진격리장치를 적용한 복층구조파이핑 시스템의 내진성능평가)

  • Ryu, Yonghee;Ju, Buseog;Son, Hoyoung
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.450-457
    • /
    • 2018
  • Purpose: The evaluation of seismic performance of critical structures has been emerging a key issue in Korea, since a magnitude 5.8 earthquake, the worst in Koran history, struck Gyeongju, southern area in Korea on september 12th, 2016. In particular, the catastrophic failure of nonstructural components such as sprinkler piping systems can cause significant economic loss or loss of life during and after an earthquake. The nonstructural components can be more fragile than structural components in seismic behavior. Method: This study presents the seismic performance evaluation of fire protection piping system, using coupled building-piping system installed with Triple Friction Pendulum Bearings (TPBs). Kobe (Japan), Kocaeli (Turkey), and GyeongJu (Korea) were selected to consider the uncertainty of ground motions in this study. Result: In the simulation results, it was observed that the reduction of maximum displacements of the piping system with the TPBs' system was significant: Kobe, Kocaeli, and Gyeongju cases were 49%, 14.4% and 21.5%, respectively. Conclusion: Therefore, using seismically isolated system in a building-piping system can be more effective to reduce the seismic risk than a normally installed building-piping systems without TPBs in strong earthquakes.

Effects of Various Humectants on Quality Properties of Pork Jerky (보습제 종류와 첨가수준이 돈육 육포의 품질특성에 미치는 영향)

  • Han, Doo-Jeong;Jeong, Jong-Youn;Choi, Ji-Hun;Choi, Yun-Sang;Kim, Hack-Youn;Lee, Mi-Ai;Lee, Eui-Soo;Paik, Hyun-Dong;Kim, Cheon-Je
    • Food Science of Animal Resources
    • /
    • v.28 no.4
    • /
    • pp.486-492
    • /
    • 2008
  • We investigated the quality properties of pork jerky prepared with various humectants (Konjac, egg albumin, isolated soy protein). Jerky was prepared as follows; control with no humectants, treatments with 0.05, 0.1, and 0.2% humectants, respectively. Humectant treatments had higher drying yields of pork jerky than the control (p<0.05), Konjac treatment produced the the highest drying yields among the humectants tested. CIE a-and b-value were lowest in isolated soy protein treatments. b-value in 0.2% egg albumin treatments were higher than other treatments (p<0.05). Jerky water content increased as humectant content increased. Water activity (Aw) in 0.2% Konjac treatments was higher than controls and 0.05% Konjac (p<0.05). In textual profile evaluations, control samples had greater hardness, cohesiveness, gumminess, and chewiness values than other treatments, but very low springiness (p<0.05). Control had significantly (p<0.05) lower scores than the other treatments in sensorial texture, juiciness and overall acceptability. Based on our findings, we conclude that 0.05% Konjac was the most effective humectant among those we tested in this study.

Investigation of Bacterial Contamination of Liquid Soaps Used in Public Restroom (공공 화장실에서 사용하는 액체 손세정제의 세균 오염도 조사)

  • Hong, Seung Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.214-220
    • /
    • 2020
  • Handwashing with soap is an important practice to reduce the transmission of potentially pathogenic microorganisms, but liquid soaps with refillable dispensers are prone to extrinsic bacterial contamination. This study investigated the bacterial contamination of liquid soaps in 58 public restrooms in six buildings. The bacteria were identified by a biochemical test and MALDI-TOF mass spectrophotometry. The antimicrobial susceptibility was determined using the Vitek II system. Of the 58 restrooms examined, 27(46.55%) were using a refill dispenser, of which 25(92.59%) were contaminated with bacteria. The bacteria recovered from the soaps ranged from 1.6×103 to 2.7×105 CFU/mL. Serratia liquefaciens (12), Achromobacter xylosoxidans (9), S. marcescens (4), Staphylococcus pastueri (1), and Achromobacter spanius (1) were isolated. Except for one A. xylosoxidans, bacteria of the same species isolated in the same building showed a unique resistance pattern. In conclusion, handwashing with contaminated soap may play a role in the transmission of bacteria in public health settings. Therefore, it is necessary to limit the use of refillable liquid soaps in the restrooms of hospitals used by patients with reduced immunity.

Isolation of Acinetobacter calcoaceticus BP-2 Capable of Degradation of Bisphenol A (Bisphenol A 분해균주 Acinetobacter calcoaceticus BP-2의 분리 및 bisphenol A 분해 특성)

  • Kwon, Gi-Seok;Kim, Dong-Geol;Lee, Jung-Bok;Shin, Kee-Sun;Kum, Eun-Joo;Sohn, Ho-Yong
    • Journal of Life Science
    • /
    • v.16 no.7 s.80
    • /
    • pp.1158-1163
    • /
    • 2006
  • Bisphenol A (BPA), 2,2-bis(4-hydroxyphenyl) propane, has been widely used as a monomer for production of epoxy resins and polycarbonate plastics, and final products of BPA include adhesives, protective coatings, paints, optical lens, building materials, compact disks and other electrical parts. Since BPA is a toxic chemical to elicit acute cell cytotoxicity and chronic endocrine disrupting activity, the degradation of BPA has been focused during last decades. To overcome the problem of photo-, and chemical-degradation of BPA, in this study, a bacterium that is able to biodegrade BPA, was isolated. The bacterium, isolated froln the soil of plastic factory, was identified as Acinetobacter calcoaceticus (strain BP-2) based on physiological and 16S rDNA sequencing analysis. A. calcoaceticus BP-2 was able to grow in the presence of $1140{\mu}g\;ml^{-1}$ BPA. Biodegradation experiments showed that BP-2 mineralized BPA via 4-hydroxybenzoic acid and 4-hydroxyacetophenone, and average degradation rate was $53.3{\mu}g\;ml^{-1}\;day^{-1}$ under optimal conditions (pH 7 and $30^{\circ}C$). In high density resting cell $(3.5g-dcw.1^{-1})$ experiments, the maximal degradation rate was increased to $89.7{\mu}g\;ml^{-1}\;h^{-1}$. Our results suggest that BP-2 has high potential as a catalyst for practical BPA bioremediation.

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

Application of Seismic Isolation and Vibration Control in Korea (우리나라의 면진 및 진동제어)

  • Lee, Dong-Guen;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.67-77
    • /
    • 2006
  • Seismic activity of Korea is not so high as that of Japan or California and most of the structures were designed without considering the influence of earthquakes until the first seismic design code was enforced in 1988. Therefore, it was very hard to find seismically isolated structures in Korea until 1980's. Korean engineers assumed that the seismic isolation or vibration control would be useful only in a high seismicity region while such technologies can be quite useful in a low seismicity region for the efficient reduction of earthquake damages. Recently, Korean engineers began to have interest in the seismic isolation or vibration control and applied it to some important structures such as LNG storage tanks, many bridges and several buildings. However, design codes are not defining such useful advanced technologies for the design of building structures and several projects employing seismic isolation or vibration control in the design of structures had difficulties in obtaining construction permit from the local government. Therefore, it is an urgent requirement to introduce these advanced technologies in the seismic design code.

Modification of MUSCL Scheme for Application of Non-uniform Grid (비정형격자의 적용을 위한 MUSCL 기법의 수정)

  • Kim, Byung-Hyun;Han, Kun-Yeon
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.1
    • /
    • pp.105-117
    • /
    • 2010
  • This paper presents a new and simple technique to perform MUSCL reconstruction for solving 2D shallow water equations. The modified MUSCL scheme uses weighted area ratio to apply non-uniform grid in stead of the previous method that equally distributed the difference of conservation variables to each interface. The suggested method can physically reconstruct conservation variables in case of uniform grid as well as non-uniform grid. In this study, Unsplit scheme applicable to unstructured grid is used and efficient slope limiter of TVD scheme is used to control numerical oscillation which can be occurred in modified MUSCL scheme. For accurate and efficient treatment of bed slope term, the modified MUSCL scheme is coupled with the surface gradient method. The finite volume model applied to suggested scheme is verified through a comparison between numerical solution and laboratory measurements data such as the simulations of isolated building test case and Bellos's dam break test case.

Association of CYP2E1, STK15 and XRCC1 Polymorphisms with Risk of Breast Cancer in Malaysian Women

  • Chong, Eric Tzyy Jiann;Goh, Lucky Poh Wah;See, Edwin Un Hean;Chuah, Jitt Aun;Chua, Kek Heng;Lee, Ping-Chin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.647-653
    • /
    • 2016
  • Background: Breast cancer is the most common type of cancer affecting Malaysian women. Recent statistics revealed that the cumulative probability of breast cancer and related deaths in Malaysia is higher than in most of the countries of Southeast Asia. Single nucleotide polymorphisms (SNPs) in CYP2E1 (rs6413432 and rs3813867), STK15 (rs2273535 and rs1047972) and XRCC1 (rs1799782 and rs25487) have been associated with breast cancer risk in a meta-analysis but any link in Southeast Asia, including Malaysia, remained to be determined. Hence, we investigated the relationship between these SNPs and breast cancer risk among Malaysian women in the present case-control study. Materials and Methods: Genomic DNA was isolated from peripheral blood of 71 breast cancer patients and 260 healthy controls and subjected to polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) analysis. Results: Our study showed that the c1/c2 genotype or subjects with at least one c2 allele in CYP2E1 rs3813867 SNP had significantly increased almost 1.8-fold higher breast cancer risk in Malaysian women overall. In addition, the variant Phe allele in STK15 rs2273535 SNP appeared to protect against breast cancer in Malaysian Chinese. No significance association was found between XRCC1 SNPs and breast cancer risk in the population. Conclusions: This study provides additional knowledge on CYP2E1, STK15 and XRCC1 SNP impact of risk of breast cancer, particularly in the Malaysian population. From our findings, we also recommend Malaysian women to perform breast cancer screening before 50 years of age.

Shared Distributed Big-Data Processing Platform Model: a Study (대용량 분산처리 플랫폼 공유 모델 연구)

  • Jeong, Hwanjin;Kang, Taeho;Kim, GyuSeok;Shin, YoungHo;Jeong, Jinkyu
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.11
    • /
    • pp.601-613
    • /
    • 2016
  • With the increasing need for big data processing, building a shared big data processing platform is important to minimize time and monetary costs. In shared big data processing, multitenancy is a major requirement that needs to be addressed, in order to provide a single isolated personal big data platform for each user, but to share the underlying hardware is shared among users to increase hardware utilization. In this paper, we explore two well-known shared big data processing platform models. One is to use a native Hadoop cluster, and the other is to build a virtual Hadoop cluster for each user. For each model we verified whether it is sufficient to support multi-tenancy. We also present a method to complement unsupported multi-tenancy features in a native Hadoop cluster model. Lastly we built prototype platforms and compared the performance of both models.