• Title/Summary/Keyword: Isolated

Search Result 24,455, Processing Time 0.036 seconds

Characteristics of Alcohol Fermentation Yeast Isolated from Potatoes (감자에서 분리한 알콜발효 효모의 특성)

  • Jeong, Yong-Jin;Kim, Ok-Mi;Seo, Ji-Hyung;Lee, Myung-Hee;Jung, So-Hyoung;Kim, Tae-Hyun
    • Food Science and Preservation
    • /
    • v.7 no.2
    • /
    • pp.228-232
    • /
    • 2000
  • To utilize abundant potatoes effectively, it was studied on alcohol fermentation strains which were isolated and identified. Fifteen yeast strains with high alcohol fermentation ability were isolated from rotted potatoes. Among them, two isolated strains, 5-3A and 10-4B showing the highest alcohol fermentation ability were identified as Zygosaccharomyces fermentati based on the morphological and physiological characteristics. Their optimum conditions for the alcohol fermentation in 25% glucose were pH 3.0, 30$^{\circ}C$ and 150 rpm of shaking speed, respectively.

  • PDF

Comparative Chemiluminescent Response of Phagocytes from Peripheral Blood, Head Kidney and Spleen of the Cultured Rockfish (Sebastes schlegeli)

  • Kim Ki Hong;Hwang Yoon Jung;Cho Jae Bum;Kwon Se Ryun
    • Fisheries and Aquatic Sciences
    • /
    • v.3 no.1
    • /
    • pp.23-25
    • /
    • 2000
  • To compare the respiratory burst activity potential of the phagocytes isolated from head kidney, spleen, and peripheral blood 1ll cultured rockfish (Sebastes schlegeli), chemiluminescent (CL) response analysis was performed. The phagocytes isolated from peripheral blood showed greater and faster CL response to the opsonized zymosan compared to that of the phagocytes isolated from kidney or spleen. This may imply a significant role of the blood phagocytes in defence mechanism of rockfish. The different responses found in the CL analysis among the phagocytes isolated from peripheral blood, kidney, and spleen may reflect differences in activation state or activity of phagocytes.

  • PDF

Isolated Fracture Dislocation of the Tarsal Navicular -A case report- (족부 주상골의 단독 골절 탈구 -증례 보고-)

  • Lee, Young-Kuk;Ahn, Won-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.3 no.1
    • /
    • pp.58-61
    • /
    • 1999
  • Isolated fracture dislocation of the tarsal navicular bone is extremely rare. The mechanism of injury of this fracture dislocation is known as a horizontal or axial load on plantar flexed foot. Closed or open reduction is recommended for displaced navicular fracture. We report one case of isolated fracture dislocation of the tarsal navicular which was treated with closed reduction and percutaneous K-wire fixation.

  • PDF

Prevalence of Antibiotic Resistant Foodborne Bacteria Isolated in Korea

  • Chung, Yun-Hee;Kim, Soo-Young;Chang, Yun-Hee
    • Food Science and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.216-222
    • /
    • 2005
  • This study was performed to determine the antibiotic susceptibility profiles of Salmonella spp., coliforms, Listeria monocytogenes, Staphylococcus aureus and Vibrio spp. isolated from broiler carcasses, aquacultured flounders, hamburgers, and lettuce, which are foods consumed in large quantities in Korea. Salmonella spp. and L. monocytogenes were isolated only from broiler carcasses and Salmonella spp. had a high multidrug resistance rate of 61.1%. Meanwhile, coliforms and S. aureus were isolated from all four foods tested in this experiment. The multidrug resistance rate of coliforms from broiler carcasses was 50%, and that of Vibrio spp. from flounders was 71.4%. The resistance to tetracycline, streptomycin, ampicillin or carbenicillin was common regardless of the kind of food or isolate.

Development of Computer Program for Seismic Response Analysis of Base Isolated Structures (면진 구조물의 지진응답 해석 프로그램 개발)

  • 정정훈;허영철;김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.348-355
    • /
    • 2001
  • A computer program named \"NLDA-BIS\", which runs under the MATLAB environment, is developed fur seismic response analysis of base isolated structures. This program can explicitly model the various nonlinear isolation elements such as elastomeric bearings, sliding bearings and general viscous dampers, and so on. Newmark'\`s constant average acceleration method fur calculating the responses in time domain and the iterative pseudo-force method for treating the nonlinear isolation forces are adopted. For capturing the hysteretic behavior of isolation elements, the modified Wen's equations are adopted and solved by the numerical differentiation formula method. To verify the validity of the developed program, the seismic responses of a six-story reinforced concrete base isolated structure are calculated and compared with results obtained by the program \"3D-BASIS\" developed at the State University of New York at Buffalo which is the most widely used code far analyzing isolated structures today.ed structures today.

  • PDF

Shaking Table Test of the Model of Five-story Stone Pagoda of Sang-Gye-Sa Mounted on Base Isolation Systems (쌍계사 오층석탑모델에 대한 지진격리효과 진동대실험)

  • 김재관;이원주;김영중;김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.331-338
    • /
    • 2001
  • Seismic performances of the base isolated model of Five Story Stone Pagoda were studied through shaking table tests. Friction pendulum system (FPS), Pure-friction system with laminated rubber bearing (LRB) and Ball with rubber bearing were selected fur the comparison of performances. Performances of specially designed isolation systems were tested dynamically using shaking table. The test results of isolated model are compared with those of fixed base model. Compared with fixed base model, the isolated model showed that it could withstand much higer intensity of earthquake motion. The Effective Peak Ground Acceleration (EPGA) value of isolated model when the top component tipped over was above twice of that value in case of fixed base model. According to the additional test results, the lower value of coefficient of friction than that of common frictional base isolation systems is more effective to protect the piled multi-block system of Pagoda against moderate intesity of ground motion.

  • PDF

Seismic Demand on the Isolated Slab-on-Steel Girder Bridge in Low Temperature (면진된 합성형교의 저온에서의 내진 요구)

  • 김대곤;김석희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.379-386
    • /
    • 2002
  • The objective of this study is to investigate the seismic demand on the isolated slab-on-steel girder bridge under cold climate conditions. To this end comparative test results are presented of laminated elastomeric and lead-rubber seismic isolators in warm and cold temperature conditions. At extremely cold temperatures, rubber "glass-harden" and as a result rubber bearings that may be used for seating bridges behave in a significantly non-linear fashion. From the nonlinear time history analysis of the isolated slab-on-steel girder bridge, larger forces are transferred to the substructures. however smaller displacement at superstructure is obtained under cold climate conditions. These phenomenons might need to be considered in design stage of the seismically isolated bridges.

  • PDF

Seismic Fragility Analysis of Base Isolated Liquid Storage Tank (면진 유체 저장 탱크의 지진취약도 분석)

  • Ahn, Sung-Moon;Choi, In-Kil;Choun, Young-Sun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.453-460
    • /
    • 2005
  • In this study, the seismic fragility analysis of a base isolated condensate storage tank installed in the nuclear power plant. The condensate storage tank is safety related structure in a nuclear power plant. The failure of this tank affect significantly to the core damage frequency of the nuclear power plants. The seismic analysis of the liquid storage tank was performed by the simple calculation method and the dynamic time storage analysis method. The convective and impulsive fluid mass is modeled as added masses proposed by several researchers. To evaluate the effectiveness of the isolation system, the comparison of HCLPF and core damage frequencies in non-isolated and isolated cases are carried out. It can be found from the results that the seismic isolation system increases the seismic capacity of a condensate storage tank and decreases the core damage frequency significantly.

  • PDF

Application of Some Semiactive Control Algorithms to a Smart Base Isolated Building Employing MR Dampers (MR감쇠기가 설치된 지진격리 건물의 스마트 진동제어)

  • Jung, Hyung-Jo;Choi, Kang-Min;Jang, Ji-Eun;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.544-551
    • /
    • 2005
  • This paper investigates the effectiveness of the MR damper-based control systems for seismic protection of base isolated building sturcutres employing some semiactive control algorithms, such as the modified clipped-optimal control, the maximum energy dissipation, and the modulated homogeneous friction, by examining the Phase I smart base isolated benchmark building problem. The results of the numerical simulations showed that most of the control systems considered herein could be beneficial in reducing seismic responses, especially base displacement or isolator deformation, of base isolated building structures. It is also verified that another version of the modified clipped-optimal control algorithm proposed in this study and the modulated homogeneous friction algorithm are more effective than other semiactive control algorithms.

  • PDF

Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling (분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상)

  • Park, Joo-Saeng;Kim, Se-Jong;Lee, Sang-Joon
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.4
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF