• Title/Summary/Keyword: Isocenter dose

Search Result 86, Processing Time 0.018 seconds

Rapid Optimization of Multiple Isocenters Using Computer Search for Linear Accelerator-based Stereotactic Radiosurgery (Multiple isocenter를 이용한 뇌정위적 방사선 수술시 컴퓨터 자동 추적 방법에 의한 고속의 선량 최적화)

  • Suh Tae-suk;Park Charn Il;Ha Sung Whan;Yoon Sei Chul;Kim Moon Chan;Bahk Yong Whee;Shinn Kyung Sub
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.109-115
    • /
    • 1994
  • The purpose of this paper is to develop an efficient method for the quick determination of multiple isocenters plans to provide optimal dose distribution in sterotactic radiosurgery. A Spherical dose model was developed through the use of fit to the exact dose data calculated in a 18cm diameter of spherical head phantom. It computes dose quickly for each spherical part and is useful to estimate dose distribution for multiple isocenters. An automatic computer search algorithm was developed using the relationship between the isocenter move and the change of dose shape, and adapted with a spherical dose model to determine isocenter separation and cellimator sizes quickly and automatically. A spheric81 dose model shows a comparable isodose distribution with exact dose data and permits rapid calculations of 3-D isodoses. the computer search can provide reasonable isocenter settings more quickly than trial and error types of plans, while producing steep dose gradient around target boundary. A spherical dose model can be used for the quick determination of the multiple isocenter plans with 3 computer automatic search. Our guideline is useful to determine the initial multiple isocenter plans.

  • PDF

Usability Evaluation of Lateral Sliding Table in CT Examination (CT 검사에서 Lateral Sliding Table의 유용성 평가)

  • Choi, Jeong Hun;Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.677-684
    • /
    • 2020
  • Miscentering in the left and right X axis direction during CT examination affects dose and quality. When the CT Gantry Isocenter and the center of the examination objective are matched using the Lateral Sliding Table, the image quality is improved and the exposure dose is reduced. CTDI Head Phantom (Kimda, Korea) and dosimeter (Ray Safe, Sweden) were used to measure dose comparison CTDI (mGy) due to center deviation, and Water Phantom (HITACHI, Japan) was used to measure noise to see the difference in uniformity due to center deviation. Measurements of doses for dose comparison CTDI (mGy) with a deviation showed that doses were consistently reduced and exact dose was not projected until they were moved to 80 mm by 20 mm from the Isocenter. SD values were measured to see the difference in uniformity due to center deviation and the noise continued to increase until it was moved by 20 mm to 80 mm. The range of collimation has increased by the extent of deviating from the center and the range of exposure has increased. Using the Lateral Sliding Table, you can easily adjust the Isocenter, increase the quality of the image by adjusting the Isocenter in areaa such as the cardiac examination of the location away from the Isocenter, Extreme bone and Shoulder, and greatly reduce the collimation to the Isocenter, so it can be used to reduce unnecessary exposure dose.

A Comparison Study with the Vatiation of Isocenter and Collimator in Stereotactic Radiosurgery (방사선 수술시 Isocenter, 콜리메이터 변수에 따른 선량 분포 비교연구)

  • 오승종;박정훈;곽철은;이형구;최보영;이태규;김문찬;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.129-134
    • /
    • 2002
  • The radiosurgery is planned that prescribed dose was irradiated to tumor for obtaining expected remedial value in stereotactic radiosurgery. The planning for many irregular tumor shape requires long computation time and skilled planners. Due to the rapid development in computer power recently, many optimization methods using computer has been proposed, although the practical method is still trial and error type of plan. In this study, many beam variables were considered and many tumor shapes were assumed cylinderical ideal models. Then, beam variables that covered the target within 50% isodose curve were searched, the result was compared and analysed. The beam variables considered were isocenter separation distance, number of isocenters and collimator size. Dose distributions obtained with these variables were analysed by dose volume histogram(DVH) and dose profile at orthogonal plane. According to the results compared, the use of more isocenters than specified isocenter dosen't improve DVH and dose profile but only increases complexity of plan. The best result of DVH and dose profile are obtainedwhen isocenter separation was 1.0-1.2 in using same number of isocenter.

  • PDF

Optimization of Dose Distribution for LINAC-based Radiosurgery with Multiple Isocenters (LINAC 뇌정위적 방사선 수술시 Multiple Isocenters를 이용한 최적 선량분포 계획)

  • Suh Tae-Suk;Yoon Sei Chul;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.351-359
    • /
    • 1991
  • The current LINAC technique for radiosurgery utilizes a single isocenter approach with multiple noncoplanar arcs. This approach results in spherical dose distributions in the target. Many arteriovenous malformations and tumors suitable for radiosurgical treatment have non-spherical or irregular shapes. The basic approach presented in this paper is to use two or multiple isocenters with standard arcs to shape irregular target volumes through the use of multiple spherical targets. Selection of reasonable irradiation parameters in the first stage is critical to the success of real-time optimization. A useful guideline for optimum isocenter separation and collimator size is developed to shape the target margin uniformly with an desired isodose surface for an elongated target. The implementation of multiple isocenters with three dimensional dose model and application of multiple isocenters approach to several cases are discussed.

  • PDF

Search of Characteristic for Dose Distribution Presented by Multi­isocentric Stereotactic Radiosurgical Plan Using Linear Accelerator (선형 가속기를 이용한 정위적 방사선 수술시 병소내 선량분포의 특성조사)

  • 최경식;오승종;이형구;최보영;전흥재;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.225-233
    • /
    • 2003
  • The goal of a radiation treatment plan is to deliver a homogeneous dose to a target with minimal irradiation of the adjacent normal tissues. Dose uniformity is especially important for stereotactic radiosurgery using a linear accelerator. The dose uniformity and high dose delivery of a single spherical dose distribution exceed 70%. This also results with a similar stereotactic radiosurgical plan using a Gamma Knife. The dose distribution produced in a stereotactic radiosurgical plan using a Gamma Knife and Linear accelerator is spherical, and the application of the sphere packing arrangement in a real radiosurgical plan requires much time and skill. In this study, we found a characteristic of dose distribution with transformation of beam parameters that must be considered in a radiosurgical plan for effective radiosurgery. First, we assumed a cylinder type tumor model and a cube type tumor model. Secondly, the results of the tumor models were compared and analyzed with dose profiles and DVH_(Dose Volume Histogram) representative dose distribution. We found the optimal composition of beam parameters_(i.e. collimator size, number of isocenter, gap of isocenters etc.), which allowed the tumor models to be involved in the isodose curve at a high level. In conclusion, the characteristics found in this study are helpful for improving the effectiveness and speed of a radiosurgical plan for stereotactic radiosurgery.

  • PDF

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.

A Smart Setup for Craniospinal Irradiation

  • Peterson, Jennifer L.;Vallow, Laura A.;Kim, Siyong;Casale, Henry E.;Tzou, Katherine S.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.230-236
    • /
    • 2013
  • Our purpose is to present a novel technique for delivering craniospinal irradiation in the supine position using a perfect match, field-in-field (FIF) intrafractional feathering, and simple forward-optimization technique. To achieve this purpose, computed tomography simulation was performed with patients in the supine position. Half-beam, blocked, opposed, lateral, cranial fields with a collimator rotation were matched to the divergence of the superior border of an upper-spinal field. Fixed field parameters were used, and the isocenter of the upper-spinal field was placed at the same source-to-axis distance (SAD), 20 cm inferior to the cranial isocenter. For a lower-spinal field, the isocenter was placed 40 cm inferior to the cranial isocenter at a constant SAD. Both gantry and couch rotations for the lower-spinal field were used to achieve perfect divergence match with the inferior border of the upper-spinal field. A FIF technique was used to feather the craniospinal and spinal-spinal junction daily by varying the match line over 2 cm. The dose throughout the target volume was modulated using the FIF simple forward optimization technique to obtain homogenous coverage. Daily, image-guided therapy was used to assure and verify the setup. This supine-position, perfect match craniospinal irradiation technique with FIF intrafractional feathering and dose modulation provides a simple and safe way to deliver treatment while minimizing dose inhomogeneity.

The Dose Distribution of Arc therapy for High Energy Electron (고에너지 전자선 진자조사에 의한 선량분포)

  • Chu, S.S.;Kim, G.E.;Suh, C.O.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF

Radiation Dose Accuracy 81 the Isocenter : Standard Stereotactic Radiosurgery Technique Developed at Seoul National University Hospital (서울대학교병원형 방사선수술 표준기법의 중심점 선량의 오차)

  • Shin Seong Soo;Kim Il Han;Ha Sung Whan;Park Charn Il;Kang Wee-Saing;Hur Sun Nyung
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.391-395
    • /
    • 2002
  • Purpose : To confirm the accuracy of the radiation dose at the isocenter by the standard linear accelerator-based stereotactic radiosurgery technique which was developed at Seoul National University Hospital. Materials and Methods : Radiation dosimetry was undertaken during standard 5-arc radiosurgery using 6 MV X-ray beam from CL2100C linac. The treatment head was attached with circular tertiary collimators of 10 and 20 mm diameter. We measured the absorbed dose at the isocenter of a multi-purpose phantom using two kinds of detector : a 0.125 co ionization chamber and a silicon diode detector. Results : The dose differences at each arc plane between the planned dose and the measured dose at the isocenter raged from $-0.73\%\;to\;-2.69\%$ with the 0.125 cc ion chamber, and from $-1.29\%\;to\;-2.91\%$ with the diode detector during radiosurgery with the tertiary collimator of 20 mm diameter. Those with the 10-mm tertiary collimator ranged from $-2.39\%\;to\;-4.25\%$ with the diode. Conclusion : The dose accuracy at the isocenter was ${\pm}3\%$. Therefore, further efforts such ws modification in processing of the archived image through DICOM3.0 format are required to lessen the dose difference.

Evaluation of the effect of mechanical deformation on beam isocenter properties of the SC200 scanning beam delivery system

  • Wang, Ming;Zheng, Jinxing;Song, Yuntao;Li, Ming;Zeng, Xianhu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2064-2071
    • /
    • 2020
  • For proton pencil beam scanning (PBS) technology, the accuracy of the dose distribution in a patient is sensitive to the properties of the incident beam. However, mechanical deformation of the proton therapy facility may occur, and this could be an important factor affecting the proton dose distribution in patients. In this paper, we investigated the effect of deformation on an SC200 proton facility's beam isocenter properties. First, mechanical deformation of the PBS nozzle, L-shape plate, and gantry were simulated using a Finite Element code, ANSYS. Then, the impact of the mechanical deformation on the beam's isocenter properties was evaluated using empirical formulas. In addition, we considered the simplest case that could affect the properties of the incident beam (i.e. if only the bending magnet (BG3) has an error in its mounting alignment), and the effect of the beam optics offset on the isocenter characteristics was evaluated. The results showed that the deformation of the beam position in the X and Y direction was less than 0.27 mm, which meets the structural design requirements. Compared to the mechanical deformation of the L-shape plate, the deformation of the gantry had more influence on the beam's isocenter properties. When the error in the mounting alignment of the BG3 is equal to or more than 0.3 mm, the beam deformation at the isocenter exceeds the maximum accepted deformation limits. Generally speaking, for the current design of the SC200 scanning beam delivery system, the effects of mechanical deformation meet the maximum accepted beam deformation limits. In order to further study the effect of the incident beam optics on the isocenter properties, a fine-scale Monte Carlo model including factors relating to the PBS nozzle and the BG3 should be developed in future research.