• Title/Summary/Keyword: Irrigation channel

Search Result 63, Processing Time 0.021 seconds

Estimation of irrigation return flow from paddy fields on agricultural watersheds (농업유역의 논 관개 회귀수량 추정)

  • Kim, Ha-Young;Nam, Won-Ho;Mun, Young-Sik;An, Hyun-Uk;Kim, Jonggun;Shin, Yongchul;Do, Jong-Won;Lee, Kwang-Ya
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • Irrigation water supplied to the paddy field is consumed in the amount of evapotranspiration, underground infiltration, and natural and artificial drainage from the paddy field. Irrigation return flow is defined as the excess of irrigation water that is not consumed by evapotranspiration and crop, and which returns to an aquifer by infiltration or drainage. The research on estimating the return flow play an important part in water circulation management of agricultural watershed. However, the return flow rate calculations are needs because the result of calculating return flow is different depending on irrigation channel water loss, analysis methods, and local characteristics. In this study, the irrigation return flow rate of agricultural watershed was estimated using the monitoring and SWMM (Storm Water Management Model) modeling from 2017 to 2020 for the Heungeop reservoir located in Wonju, Gangwon-do. SWMM modeling was performed by weather data and observation data, water of supply and drainage were estimated as the result of SWMM model analysis. The applicability of the SWMM model was verified using RMSE and R-square values. The result of analysis from 2017 to 2020, the average annual quick return flow rate was 53.1%. Based on these results, the analysis of water circulation characteristics can perform, it can be provided as basic data for integrated water management.

Biodegradable Check Dam and Synthetic Polymer, its Experimental Evaluation for Turbidity Control of Agricultural Drainage Water

  • Kim, Minyoung;Kim, Seounghee;Kim, Jinoh;Lee, Sangbong;Kim, Youngjin;Cho, Yongho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.6
    • /
    • pp.458-462
    • /
    • 2013
  • A drainage ditch is normally a component of drainage networks in farming systems to remove surplus water, but at the same time, it may act as a major conduit of agricultural nonpoint source pollutions such as sediment, nitrogen, phosphorus, and so on. The hybrid turbidity reduction system using biodegradable check dam and synthetic polymer was developed in this study to manage pollutant discharge from agricultural farmlands during rainfall events and/or irrigation periods. The performance of this hybrid system was assessed using a laboratory open channel sized in 10m-length and 0.2m-width. Various check dams using agricultural byproducts (e.g., rice straw, rice husks, coconut fiber and a mixture of rice husks and coconut fiber) were tested and additional physical factors (e.g., channel slope, flowrate, PAM dosage, turbidity level, etc.) affecting on turbidity reduction were applied to assess their performance. A series of lab experiments clearly showed that the hybrid turbidity reduction system could play a significant role as a supplementary of Best Management Practice (BMP). Moreover, the findings of this study could facilitate to develop an advanced BMP for minimizing nonpoint source pollution from agricultural farmlands and ultimately to achieve the sustainable agriculture.

Evaluation of the mechanical pipe flowmeter at low hydraulic head (저수두에서 기계식 관수로 유량계의 적용성 평가)

  • Sohn, Seung-Ho;Chung, Sang-Ok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.53-56
    • /
    • 2002
  • This study presents an evaluation of the mechanical pipe flowmeter at low hydraulic heads. Three flowmeters each of 75mm and 25mm diameter were used. The Flowmeter was tested with experimental open channel apparatus. Relationship between flowmeter values and bucket values was good. The 75mm diameter flow meter showed small relative errors with hydraulic heads above 9cm. The 25mm diameter flow meter showed small relative errors with hydraulic heads above 2cm. The Irrigation flow measurement using the mechanical pipe flowmeter of 75mm diameter in paddy fields needs hydraulic head above 9cm, which is easy to get in tertiary canals.

  • PDF

A Study on Ecological Changes of naturally favorable Consolidated channel (자연친화적 정비수로의 생태변화에 관한 연구)

  • Kim, Sun-Joo;An, Min-Woo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.236-240
    • /
    • 2001
  • When we make on irrigation and drainage canals, the environment should be preferentially taken into consideration. The purpose of this study is to test Close-to-nature Consolidation Techniques in the drainage canals of Samsungri, Kanam-myun, Yeoju-gun, Kyunggi-do. The monitoring and assessment of these techniques has been conducted during two years, focuesed the drainage canals ecological habitat and landscape. As the result of this study, the embankment covered with Close-to-nature Consolidation Techniques played an important role as a habitat for aquatic animal, fish and birds as well as the groth emergement plant.

  • PDF

Study on the region selection for the creation of the naturally favorable waterfront area (자연친화적 수변공간조성 지역선정을 위한 연구(농지조성 및 농어촌정비))

  • 김선주;양용석;안민우
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.96-101
    • /
    • 2000
  • Nowadays, everyone emphasis the important of environment. it is found that try to apply using the naturally favorable method when arrange irrigation and drainage channel. But we have no accurate standard of region selection yet. so it is make a many problem. The purpose of this study is the making of standard which is optimal region selection for the creation of the naturally favorable waterfront area. We surveyed data of twenty site in korea where are managed by the KARICO(Korea Agricultural Rural Infrastructure Corporation). We analysed the data using suitable three method(simple adding point method, subjectivity decision method, checklist method) for purpose of this study.

  • PDF

An Analysis on the Long-Term Runoff of the Yong San River (영산강의 장기유출량에 관한 고찰)

  • 한상욱;정종수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.3
    • /
    • pp.4184-4194
    • /
    • 1976
  • Located in the southwestern part of Korea, the Yong San Gang river flows generally northeast to southwest, and because of the specific location, topography and climate, the basin area is subject to recurrent drought and flood damages. To eliminate the cause of such damages and ensure an increase in the farm income by means of effective irrigation supply and increased cropping intensity, efforts are being made to speed up implementation of an integrated agricultural development project which would include construction. of an estuary dam and irrigation facilities as well as land development and tidal reclarnation. In formulating a basin development project plan, it is necessary to study a series of long-term runoff data. The catchment area at the proposed estuary damsite is 3,471$\textrm{km}^2$ with the total length of the river channel up to this point reaching 138km. An analysis of runoff in this area was carried out. Rainfall was estimated by the Thiessen Network based on records available from 15 of the rainfall observation stations within the area. Out of the 15 stations, Kwang Ju and Mok Po stations were keeping long-term precipitation records exceeding some 60 years while the others were in possession of only 5-10 years records. The long-term records kept by those stations located in the center of the basin were used as base records and records kept by the remaining stations were supplemented using the coefficient of correlation between the records kept by the base stations and the remainder. The analyses indicate that the average annual rainfall measured at Kwang Ju during 1940-1972 (33 years) amounts to 1,262mm and the areal rainfall amounts to 1,236mm. For the purpose of runoff analysis, 7 observatories, were set up in the middle and lower reaches of the river and periodic measurements made by these stations permitted analysis of water levels and river flows. In particular, the long-term data available from Na Ju station significantly contributed to the analysis. The analysis, made by 4-stage Tank method, shows that the average annual runoff during 1940-1972 amounts to 2,189 million ㎥ at the runoff rate of 51%. As for the amount of monthly runoff, the maximum is 484.2 million ㎥ in July while the minimum is 48.3 million ㎥ in January.

  • PDF

Possible Uses of Reclaimed Wastewater Effluent Treated Using Birm Filtration Along UF, and Analysis on Membrane Fouling (하수방류수 재이용을 위한 Birm filter + UF 적용시 용도별 사용 가능성 및 막오염 특성)

  • Jung, Jin-Hee;Lee, Seung-Chul;Sung, Nak-Chang;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.25 no.11
    • /
    • pp.1467-1474
    • /
    • 2016
  • In response to the water shortage problem, continued attempts are being made to secure consistent and reliable water sources. Among various solutions to this problem, wastewater effluent is an easy way to secure the necessary supply, since its annual output is consistent. Furthermore, wastewater effluent has the advantage of being able to serve various purposes, such as cleaning, sprinkling, landscaping, river management, irrigation, and industrial applications. Therefore, this study presents the possible use of reclaimed industrial wastewater treated with Birm filters and a UF membrane, along with an analysis on membrane fouling. The preprocessing stage, part of the reclamation process, used Birm filters to minimize membrane fouling. Since this study did not consider heavy metal levels in the treated water, the analyses did not include the criterion for irrigation water quality. However, the wastewater reclaimed by using Birm filters and a UF membrane met every other requirement for reclaimed water quality standards. This indicated that the treated water could be used for cleaning, channel flow for maintenance, recreational purposes, and industrial applications. The analysis on the fouling of the Birm filter and UF membrane required the study of the composition and recovery rate of the membrane. According to SEM and EDX analyses of the UF membrane, carbon and oxygen ion composition amounted to approximately 57%, whereas inorganic matter was not detected. Furthermore, the difference in the recovery rates of the distressed membrane between acidic and alkaline cleaning was more than ~78%, which indicated that organic rather than inorganic matter contributed to membrane fouling.

Dynamics of Cyanobacterial Toxins in the Downstream River of Lake Suwa (Suwa호 하류하천에서의 남조류 독소의 동태)

  • Kim, Bom-Chul;Park, Ho-Dong;Katagami, Yukimi;Hwang, Soon-Jin;Kim, Ho-Sub
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.1 s.93
    • /
    • pp.45-53
    • /
    • 2001
  • Transport of cyanobacterial toxins (microcystin-LR, -RR, -YR) were assessed from a eutrophic lake, Lake Suwa, through the outflowing river, the Tenryu River, and its irrigation channel branch. Temporal variation of phytoplankton species composition in the river coincided with those of the lake; Microcystis ichthyoblabe dominated from June to July, and M. viridis dominated from August to September. When cyanobacterial bloom occurred, microcystins were continuously detected at the concentration of $0.3{\sim}3.2\;{\mu}g/l$ even at 32 km downstream. The change of the content of three microcystin variants were related both with the total cell density of Microcystis and with the change of Microcystis species composition. When Microcystis ichthyoblabe dominated during July, only microcystin-RR (MC-RR) and -LR (MC-LR) were detected, while when Microcystis viridis dominated between August and October, microcystin-RR,-YR (MC -YR) and -LR were detected. Along 29 km flowing distance (flow time 11 hours) between site 2 and site 5 in the Tenryu River, cyanobacterial density and microcystin concentration were reduced by 73% and 72%, respectively, which is mostly contributed by the dilution effect of tributary waters (61% and 57%, respectively) . In the artificial irrigation channel microcystins and cyanobacterial cells were decreased less than in the natural river. The results indicate that cyanobacterial toxins can be transported far downstream without much removal and give hazards to water usage in downstream of eutrophic lakes with cyanobacterial blooms.

  • PDF

Horizontal-Axis Screw Turbine as a Micro Hydropower Energy Source: A Design Feasibility Study (마이크로 수력 에너지원의 수평축 스크류 터빈 : 설계 타당성 연구)

  • SHAMSUDDEEN, MOHAMED MURSHID;KIM, SEUNG-JUN;MA, SANG-BUM;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.1
    • /
    • pp.95-104
    • /
    • 2022
  • Micro hydropower is a readily available renewable energy source that can be harvested utilizing hydrokinetic turbines from shallow water canals, irrigation and industrial channel flows, and run-off river stream flows. These sources generally have low head (<1 m) and low velocity which makes it difficult to harvest energy using conventional turbines. A horizontal-axis screw turbine was designed and numerically tested to extract power from such low-head water sources. The 3-bladed screw-type turbine is placed horizontally perpendicular to the incoming flow, partially submerged in a narrow water channel at no-head condition. The turbine hydraulic performances were studied using Computational Fluid Dynamics models. Turbine design parameters such as the shroud diameter, the hub-to-shroud ratios, and the submerged depths were obtained through a steady-state parametric study. The resulting turbine configuration was then tested by solving the unsteady multiphase free-surface equations mimicking an actual open channel flow scenario. The turbine performance in the shallow channel were studied for various Tip Speed Ratios (TSR). The highest power coefficient was obtained at a TSR of 0.3. The turbine was then scaled-up to test its performance on a real site condition at a head of 0.3 m. The highest power coefficient obtained was 0.18. Several losses were observed in the 3-bladed turbine design and to minimize losses, the number of blades were increased to five. The power coefficient improved by 236% for a 5-bladed screw turbine. The fluid losses were minimized by increasing the blade surface area submerged in water. The turbine performance was increased by 74.4% after dipping the turbine to a bottom wall clearance of 30 cm from 60 cm. The final output of the novel horizontal-axis screw turbine showed a 2.83 kW power output at a power coefficient of 0.63. The turbine is expected to produce 18,744 kWh/year of electricity. The design feasibility test of the turbine showed promising results to harvest energy from small hydropower sources.

Channels Packed with Porous Media to Improve Water Quality for Irrigation Reservoirs (관개용 저수지 수질개선을 위한 접촉산화수로)

  • Park, Byung-Heun;Jang, Jung-Ryul;Kim, Young-Kyeong;Lee, Kwang-Sik;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.122-127
    • /
    • 2000
  • A stream purification system was applied to the upper reaches of the Masan Reservoir to improve the water quality. This system consisted of two channels which were constructed on both sides of the stream, one side packed with crushed gravels and the other with plastic filter media. The system operated under low pollutant concentrations and high hydraulic loadings during a dry season to avoid clogging of the filter media. Removal rate and efficiency of chemical oxygen demand (COD) in the channel packed with crushed gravel were $14.8g/m^3/d$ and 11.5%, and for the channel with plastic filter media, $50.1g/m^3/d$ and 13.5%, respectively. Removal efficiencies of total phosphorus (T-P) were 6.6% (gravel) and 10.0% (plastic media). These results indicated plastic filter media having relatively high specific surface areas were more efficient than crushed gravels in removing pollutants. However, due to low influent water quality during dry season, the removal efficiencies were low. The proportion of nitrate nitrogen to total nitrogen (T-N) of the inflow was high but, as the system operated under aerobic condition, nitrate nitrogen could not denitrified. Accordingly, total nitrogen was not attenuated with this system. To improve the reservoir water quality effectively, this system should be able to treat the storm runoff containing higher pollutant loadings. When the filter materials are clogged by the storm runoff instead of backwashing, it would be more efficient to replace them, Therefore, the use of natural materials which are light, easily obtaining and replaceable, and have high specific surface areas is recommended.

  • PDF