• Title/Summary/Keyword: Irregular shape target

Search Result 22, Processing Time 0.025 seconds

Shape control of cable structures considering concurrent/sequence control

  • Shon, Sudeok;Kwan, Alan S.;Lee, Seungjae
    • Structural Engineering and Mechanics
    • /
    • v.52 no.5
    • /
    • pp.919-935
    • /
    • 2014
  • In this study, the control of the shape of pre-stressed cable structures and the effective control element were examined. The process of deriving the displacement control equations using the force method was explained, and the concurrent control scheme (CCS) and the sequence control scheme (SCS) were proposed. To explain the control scheme process, the quadrilateral cable net model was adopted and classified into a regular model and an irregular model for the analysis of the control results. In the control analysis of the regular model, the CCS and SCS analysis results proved reliable. For the SCS, the errors occur in the control stage and varied according to the control sequence. In the control analysis of the irregular model, the CCS analysis result also proved relatively reliable, and the SCS analysis result with the correction of errors in each stage was found nearly consistent with the target shape after the control. Finally, to investigate an effective control element, the Geiger cable dome was adopted. A set of non-redundant elements was evaluated in the reduced row echelon form of a coefficient matrix of control equations. Important elements for shape control were also evaluated using overlapping elements in the element sets, which were selected based on cable adjustments.

Optimization of Dose Distribution for LINAC-based Radiosurgery with Multiple Isocenters (LINAC 뇌정위적 방사선 수술시 Multiple Isocenters를 이용한 최적 선량분포 계획)

  • Suh Tae-Suk;Yoon Sei Chul;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.351-359
    • /
    • 1991
  • The current LINAC technique for radiosurgery utilizes a single isocenter approach with multiple noncoplanar arcs. This approach results in spherical dose distributions in the target. Many arteriovenous malformations and tumors suitable for radiosurgical treatment have non-spherical or irregular shapes. The basic approach presented in this paper is to use two or multiple isocenters with standard arcs to shape irregular target volumes through the use of multiple spherical targets. Selection of reasonable irradiation parameters in the first stage is critical to the success of real-time optimization. A useful guideline for optimum isocenter separation and collimator size is developed to shape the target margin uniformly with an desired isodose surface for an elongated target. The implementation of multiple isocenters with three dimensional dose model and application of multiple isocenters approach to several cases are discussed.

  • PDF

Comparison of Volumetric Modulated Arc Therapy and Non-coplanar Fixed-field Intensity Modulated Radiation Therapy for Irregular Target adjacent to Organ At Risk (손상위험장기에 인접한 불규칙한 모양의 타겟 치료 시, 용적변조회전 방사선치료와 비동일평면상의 빔을 이용한 세기변조 방사선치료의 유용성 평가 및 비교)

  • Kim, Kyung Ah;Na, Kyung Soo;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.57-68
    • /
    • 2017
  • Purpose: The purpose of this study was to compare volumetric modulated arc therapy(VMAT) with fixed-field intensity modulated radiation therapy(IMRT) using non-coplanar beam when the shape of target is irregular and the location is adjacent to organ at risk(OAR). Materials and Methods: The subjects of this study were a total of 6 patients who had radiation therapy for whole scalp(2 patients), partial scalp(2 patients), and whole ventricle(2 patients) by True Beam STX(Varian Medical Systems, USA). VMAT plans consisted of coplanar or non-coplanar arcs which can minimize the volume of OAR included in beamlets. All fixed-field IMRT plans consisted of non-coplanar beams using more than 2 angles of Couch. Results: The VMAT and IMRT plans were compared with regard to the maximum dose of both lens, both optic nerves, optic chiasm, and brain stem and the mean dose of both eyeballs and hippocampus. VMAT plans showed higher dose than ncIMRT plans at more than 6 of all OARs in every patient, and the ratio was from 1.1 times to 8.2 times. In case of total scalp and partial scalp, the volume of brain which received more than 20 Gy in the VMAT plans was 2 times larger than the volume in the ncIMRT plans. In case of whole ventricle, there was no significant difference. Target coverage was satisfied in both plans($PTV_{100%}=95%$). The maximum dose in target volume and required monitor unit(MU) of ncIMRT were higher than them of VMAT plans. Conclusion: Even though ncIMRT is less efficient than VMAT with regard to required MU and treatment time, the dose to OARs is much lower than VMAT and PTV Coverage is similar with VMAT. If the shape of target is irregular and location is adjacent to OAR, comparison VMAT plan with ncIMRT plan deserves to be considered.

  • PDF

Bi-material Bolus for Minimizing the Non-uniformity of Proton Dose Distribution

  • Takada, Yoshihisa;Kohno, Syunsuke
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.214-215
    • /
    • 2002
  • Generally uniform dose distribution is assumed to be formed in a target region when a conventional dose formation method using a broad proton beam, a fixed modulation technique, a bolus and an aperture is employed. However, actual situations differ. We usually find non-uniformity in the target region. This is due to the insertion of a range-compensating bolus before the patient. Since the range-compensating bolus has an irregular shape, the scattering in the bolus depends on the lateral position. Dose distribution is overlapping results of dose distribution of pencil-proton beams traversing different lateral positions of the bolus. The lateral extent of dose distribution of each pencil beam traversing the different position differs each other at the same depth in the target object. This is a cause of the non-uniformity of the dose distribution. Therefore the same lateral extent of dose distribution should be attained for different pencil beams at the same depth to obtain a uniform dose distribution. For that purpose, we propose here a bi-material bolus. The bi-material bolus consists of a low-Z material determining mainly the range loss and a high-Z material defining mainly the scattering in the bolus. After passing through the bi-material bolus, protons traversing different lateral positions will have different residual range yet with the same lateral spread at a certain depth. Using the optimized bi-material bolus, we can obtain a more uniform dose distribution in the target region as expected.

  • PDF

Preparation of Nano-Sized ITO Powder from Waste ITO Target by Spray Pyrolysis Process (폐(廢) ITO 타겟으로부터 분무열분해(噴霧熱分解) 공정(工程)에 의한 ITO 나노 분말(粉末) 제조(製造))

  • Yu, Jae-Keun;Kang, Seong-Gu;Sohn, Jin-Gun
    • Resources Recycling
    • /
    • v.16 no.1 s.75
    • /
    • pp.28-36
    • /
    • 2007
  • Nano-sized ITO powders with the average particle size below 50 nm were synthesized from complex acid solution dissolved the ITO target into hydrochloric acid by a spray pyrolysis process, and the influences of reaction factors as reaction temperature and concentration of raw material solution were investigated. As the reaction temperature increases from 800 to $1000^{\circ}C$, the average particle size of the ITO powder increases from 40 nm to 100 nm, the microstructure gradually becomes solid, individual particles independently appear with the shape of polygon, the particle size distribution becomes increasingly irregular, the XRD peak intensity gradually increases and the specific surface area decreases. As the concentration of the raw material solution increases from 50g/l to 400g/l, the average particle size of ITO powder gradually increases, yet the particle size distribution appears more irregular. When the concentration is at 50 g/l, the average particle size of ITO powder is below 30 nm and the particle size distribution appears comparatively uniform. Nevertheless, when the concentration reaches 400 g/l, which is close to e saturated concentration, the particle size distribution appears extremely irregular, and the particles with the size ranging from 20 nm to 100 nm coexist. Along with the concentration rise, the XRD peak intensity gradually increases, yet the specific surface area decreases.

Nonlinear Irregular Waves-current Interaction on Flow Fields with Wave Breaking around Permeable Submerged Breakwater (투과성잠제 주변에서 쇄파를 동반한 불규칙파-흐름장의 상호작용)

  • Lee, Kwang-Ho;Bae, Ju-Hyun;An, Sung-Wook;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.2
    • /
    • pp.39-50
    • /
    • 2018
  • In this study, the nonlinear interaction of irregular waves with wave breaking and currents around permeable submerged breakwater was investigated with the aid of olaFlow model which is open source CFD software published under the GPL license. The irregular wave performance of olaFlow applied in this study was verified by comparing and evaluating the target frequency spectrum and the generated frequency spectrum for applicability to irregular waves. Based on the applicability of this numerical model to irregular wave fields, in the coexistence fields of irregular waves and currents, the characteristics of wave height, frequency spectrum, breaking waves, averaged velocity and turbulent kinetic energy around porous submerged breakwater with the respect to the beach type and current direction versus wave propagation were carefully investigated. The numerical results revealed that the shape of wave breaking on the crown of the submerged breakwater and the formation of the mean flow velocity around the structure depend greatly on the current directions and the type of the beach. In addition, it was found that the wave height fluctuation due to the current direction with respect to the wave propagation is closely related to the turbulent kinetic energy.

Dose Distributions for Ll NAC Radiosurgery with Dynamically Shaping Fields (선형가속기를 이용한 방사선 수술시 Dynamical Field Shaping에 의한 선량분포)

  • Suh Tae Suk;Yoon Sei Chul;Kim Moon Chan;Jang Hong Seok;PArk Yong Whee;Shinn Kyung Sub;Park Charn Il;Ha Sung Whan;Kang Wee Saing
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.431-437
    • /
    • 1993
  • An important problem in radiosurgery is the utilization of the proper beam parameters, to which dose shape is sensitive. Streotactic radiosurgery techniques for a linear accelerator typically, use circular radiation fields with multiple arcs to produce an spherical radiation distribution. Target volumes are irregular in shape for a certain case, and spherical distributions can irradiate normal tissues to high dose as well as the target region. The current improvement to dose distribution utilizes treating multiple isocenters or weighting various arcs to change treatment volume shape. in this paper another promising study relies upon dynamically shaping the treatment beam to fit the beam's eye view of the target. This conformal irradiation technique was evaluated by means of visual three dimensional dose distribution, dose volume histograms to the target volume and surrounding normal brain. It is shown that using even less arcs than multiple isocenter irradiation technique, the conformal therapy yields comparable dose gradients and superior homogeneity of dose within the target volume.

  • PDF

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

Effect of RF Power on SnO Thin Films Obtained by Sputtering (스퍼터링에 의해 제조된 SnO 박막의 RF 파워에 따른 특성 연구)

  • Um, Joseph;Roh, Byeong-Min;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.5
    • /
    • pp.399-403
    • /
    • 2012
  • SnO thin films were fabricated by rf reactive sputtering on borosilicate substrates with an Sn target and Ar/$O_2$ gas mixture. The effect of rf power on the structural, electrical, and optical properties of SnO thin films was investigated with XRD, AFM, SEM, Hall effect measurements, and UV-Vis spectrometer. As a plasma power increased the crystallinity with a preferred orientation of SnO thin films was improved and the grain size slightly increased. However the grains were coalesced and excessively irregular in shape. The electrical conductivity of SnO thin films demonstrated a relatively low p-type conductivity of 0.024 $(Wcm)^{-1}$ at a higher power condition. Lastly, SnO thin films had poor optical transmittance in the visible range as a plasma power increased.

Search for Very Fast Variability in AGN Radio Light Curves

  • Lee, Taeseok;Trippe, Sascha;Sohn, Bong Won;Lee, Sang-Sung;Byun, Do-Young;Oh, Junghwan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.43.2-43.2
    • /
    • 2013
  • AGN are known for irregular variability on all time scales, down to intra-day variability with relative variations of a few percent within minutes to hours. In the shortest time scale of AGN activity, unexplored territory still exists: first, the existence of a shortest time scale of AGN activity and secondly the shape of high frequency end of AGN power spectrum. Also the spectral variations at the shortest timescale. Here, we present the preliminary results of AGN fast photometry performed with Korean VLBI Network(KVN). Observations were done in a 'anti-correlated' mode using two antennas, with always either one antenna pointing at the target. This results in an effective time resolution of 3 minutes. We used all four KVN frequencies, 22, 43, 86, and 129 GHz, in order to trace spectral variability. We have been able to derive high-quality light curves for 3C111 and 3C279 at 22 and 86 GHz observed on 31st of May and 30th of Nov. in 2012. We are currently performing detailed statistical analysis in order to assess the levels of variability or the corresponding upper limits.

  • PDF