• Title/Summary/Keyword: Irradiation time

Search Result 1,445, Processing Time 0.036 seconds

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Factors affecting hematologic recovery and infection in high-dose chemotherapy and autologous stem cell transplantation in patients with high-risk solid tumor (소아 고형종양의 고용량 화학요법 후 자가 조혈모세포이식에서 혈액학적 회복과 감염에 영향을 주는 요인)

  • Lee, Jung Hyun;Lee, Bo Lyun;Lee, Soo Hyun;Yoo, Keon Hee;Sung, Ki Woong;Jung, Hye Lim;Cho, Eun Joo;Koo, Hong Hoe
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.10
    • /
    • pp.1079-1085
    • /
    • 2006
  • Purpose : The purpose of this study was to evaluate factors affecting hematologic recovery and infection in high-dose chemotherapy(HDCT) and autologous stem cell transplantation(ASCT) in patients with high-risk solid tumor. Methods : From January 2004 to December 2005, 72 HDCTs and ASCTs were applied to children with high-risk solid tumor at Samsung Medical Center. Medical records of these 72 HDCTs and ASCTs were retrospectively analyzed. Results : The single most powerful predictor of neutrophil and platelet recovery was the number of transplanted $CD34^+$ cells. The duration of high fever was significantly longer in young patients, in patients treated with total body irradiation and/or thiotepa, and in patients transplanted with lower $CD34^+$ cell dose(<$2{\times}10^6/kg$). However, the difference in the duration of high fever according to the number of $CD34^+$ cells was not clinically significant. Conclusion : Findings in this study suggest that HDCT and ASCT with low $CD34^+$ cell dose is clinically feasible despite delayed hematologic recovery, especially at a dose >$1{\times}10^6/kg$ per transplantation. Therefore, it is important not to defer the appropriate time for HDCT for an additional collection of hematopoietic stem cells if the number of collected $CD34^+$ cells is >$1{\times}10^6/kg$ per transplantation.

Inhibitory Effect of Taurine on HOCl-and $NH_2Cl-induced$ Degradation of Hyaluronic Acid (HOCl과 $NH_2Cl$에 의한 Hyaluronic Acid의 변성에 있어서 Taurine의 억제 효과)

  • Lee, Chung-Soo;Lee, Kyung-Yong;Lee, Kwang-Soo
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 1992
  • Effect of exogenous taurine on HOCl, $NH_2Cl$ and other oxidants-induced degradation of hyaluronic acid was investigated. The scavenging action of taurine on HOCl, $NH_2Cl$ and other oxidants was examined. The antioxidant action of taurine was also compared with that of thiol compounds. Viscosity of hyaluronic acid was markedly decreased by HOCl and $NH_2Cl$ on a dose dependent fashion. The degradative effect of HOCl on hyaluronic acid was greater than that of $NH_2Cl$. Taurine effectively inhibited HOCl-and $NH_2Cl-induced$ degradation of hyaluronic acid in a dose dependent fashion. The degradative effect of HOCl was markedly inhibited by DMSO. $Fe^{2+}$ plus $H_2O_2-induced$ degradation of hyaluronic acid was inhibited by catalase and DMSO but not affected by taurine. The desradative action of xanthine and xanthine oxidase was effectively inhibited by SOD and catalase but not affected by taurine. HOCl was significantly decomposed by taurine, DMSO, GSH and MPG. Both absorbance of HOCl at 250 nm and absorbance of $NH_2Cl$ at 242 nm were significantly increased by the addition of taurine. Interaction of $NH_2Cl$ with GSH or MPG showed an initial peak absorbance, but these absorbances were gradually decreased with time. OH production in the presence of $Fe^{2+}$ and $H_2O_2$ was inhibited by catalase and DMSO but not affected by taurine. Taurine did not affect $^1O_2$ production by U.V. irradiation which is responsible for DABCO and DABA. GSH and MPG markedly inhibited the degradative action of HOCl. These results suggest that the protective action of taurine on oxidants-induced damages of tissue components, including degradation of hyaluronic acid may be attributable to both its scavenging action on HOCl and $NH_2Cl$ and the complex formation of taurine with HOCl or $NH_2Cl$ without scavenging action on oxygen free radicals. Sulfhydryl group of taurine appears to show partially a protective action on HOCl-and $NH_2Cl-induced$ degradation.

  • PDF

Radiation Results and Survival Rate of Small Cell Lung Cancer (소세포폐암의 방사선치료 성적 및 생존율)

  • Oh, Won-Yong;Song, Mi-Hee;Whang, In-Soon
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.105-113
    • /
    • 1996
  • Purpose : To improve treatment modality and results by analysis of clinical characteristics, local control, survival and recurrence rate in limited stage small cell lung cancer. Materials and Methods : patients with limited stage small cell lung cancer were treated with combined radiation and chemotherapy from Feb. 1986 to Dec. 1992 at the National Medical Center We followed up on 21 patients ($81\%$), who were mostly irradiated with 4,000-5.000cGy ($75\%$ of all Patients) in the results by the analysis retrospectively. Survival rate was evaluated by the Kaplan-Meier method Results : Mean survival of irradiated patients with limited small cell lung cancer was 12 months. 1-rear and 2-rear survival rate were $65.3\%$ and $15.4\%$ Tumor response rate and median survival after combined chemotherapy and irradiation were the following: $50\%$ and 15 months of complete response, and $23\%$ and 11 months of partial response respectively. Response rates by radiation dose were $66\%$ for below 4,000cGy $69\%$ for between 4,000-5,000cGy and $86\%$ for above 5,000cGy. 21 of all patients showed treatment failure($81\%$) which as appeared 9 of local failure.9 of distant failure and 3 of local and distant failure. Conclusion : Local response rate after induction chemotherapy alone in limited stage of small cell lung cancer was $54\%$. Furthermore it was increased to $73\%$ after adding of radiation. We have to increase radiation dose above 5,000cGy and need to try new effective chemotherapy agents for the improvement of local control and survival rate and also will try concurrent chemoradiotherapy in near time.

  • PDF

The Use of MTT Assay, In Vitro and Ex Vivo, to Predict the Radiosensitivity of Colorectal Cancer (In-vitro와 Ex-vivo MTT Assay를 통한 직장암의 방사선치료 감수성 예측 가능성 검증)

  • Kim, Ji-Eun;Kim, Mi-Sook;Kang, Chang-Mo;Kim, Jong-Il;Shin, Hye-Kyung;Choi, Chul-Won;Seo, Young-Seok;Ji, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.166-172
    • /
    • 2008
  • Purpose: The measurement of radiosensitivity of individuals is useful in radiation therapy. Unfortunately, the measurement of radiation survival using a clonogenic assay, which is the established standard, can be difficult and time consuming. The aim of this study is to compare radiosensitivity results obtained from the MTT and clonogenic assays, and to evaluate whether the MTT assay can be used on clinical specimens. Materials and Methods: HCT-8, LoVo, CT-26, and WiDr were the colon cancer cell lines used for this study. The clonogenic assay was performed to obtain the cell survival curves and surviving fractions at a dose of 2 Gy ($SF_2$) as the standard technique for radiosensitivity. Also, the MTT assay was performed for each of the cell lines (in vitro). To simulate clinical specimens, the cell lines were inoculated into nude mice, removed when the tumors reached 1 cm in diameter, and chopped. Next, the tumors were subjected to the same process involved with the MTT assay in vitro. The inhibition rates (IR) of 10 Gy or 20 Gy of irradiation for in vitro and ex vivo were calculated based on the optical density of the MTT assay, respectively. Results: According to $SF_2$ and the cell survival curve, the HCT-8 and WiDr cell lines were more resistant to radiation than LoVo and CT-26 (p<0.05). The IR was measured by in vitro. The MTT assay IR was 17.3%, 21%, 30% and 56.5% for the WiDr, HCT-8, LoVo and CT-26 cell lines, respectively. In addition, the IR measured ex vivo by the MTT assay was 23.5%, 26%, 38% and 53% in the HCT-8, WiDr, LoVo and CT-26 tumors, respectively. Conclusion: The radiosensitivity measured by the MTT assay was correlated with the measures obtained from the clonogenic assay. This result highlights the possibility that the MTT assay could be used in clinical specimens for individual radiosensitivity assays.

EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT (LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향)

  • Chung, Yang-Seok;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.623-631
    • /
    • 2007
  • Effect of Soft-start curing on the contraction stress of composite resin restoration polymerized with LED and plasma curing unit The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin (Filtek $Z-250^{TM}$, 3M ESPE, USA) was cured using the one-step continuous curing method with three difference light sources ; conventional halogen light ($XL3000^{TM}$, 3M ESPE, USA) cure for 40 seconds at $400 mw/cm^2$, LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure for 20 seconds at $800\;mW/cm^2$ a and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure for 12 seconds at $1300 mW/cm^2$. For the soft-start curing method ; LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure exponential increase with 5 seconds followed by 17 seconds at $800\;mW/cm^2$ and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure 2 seconds light exposure at $650\;mW/cm^2$ followed by 11 seconds at $1300\;mW/cm^2$. The strain guage method was used for determination of polymerization contraction. Measurements were recorded at each 2 second for the total of 800 seconds including the periods of light application. Obtained data were analyzed statically using Repeated measures ANOVA, One way ANOVA, and Tukey test. The results of present study can be summarized as follows: 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05). 2. Contraction stress was not revealed significant difference between Halogen curing light groups and LED and Plasma Light curing with soft-start group (P>0.05). 3. LED and Plasma Light curing with soft-start showed lower contraction stress than the one-step continuous light curing (P<0.05).

  • PDF

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

The Output Factor of Small Field in Multileaf Collimator of 6 MV Photon Beams (다엽제한기 소조사면의 6 MV 광자선 출력선량계수)

  • Lee, Ho Joon;Choi, Tae-Jin;Oh, Young Kee;Jeun, Kyung Soo;Lee, Yong Hee;Kim, Jin Hee;Kim, Ok Bae;Oh, Se An;Kim, Sung Kyu;Ye, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • The IMRT is proper implement to get high dose deliver to tumor as its shape and selective approach in radiation therapy. Since the IMRT is performed as modulated the radiation fluence by the MLC created the open shapes and its irradiation time, the dose of segment of radiation field effects on the cumulated portal dose. The accurate output factor of small and step shape of segment is important to improve the determination of deliver tumor dose as it is directly proportional to dose. This experiment performed with the 6 MV photon beam of Clinac Ex(Varian) from $3{\times}3cm^2$ to $0.5{\times}0.5cm^2$ small field size for collimator jaw in MLC free and/or for MLC open field in fixed collimator jaw $10{\times}10cm^2$ using the CC01 ion chamber, SFD diode, diamond detector and X-Omat film dosimetry. As results of normalized to the reference field of $10{\times}10cm^2$ of MLC, the output factor of $3{\times}3cm^2$ showed $0.899{\pm}0.0106$, $0.855{\pm}0.0106$ for $2{\times}2cm^2$, $0.764{\pm}0.0082$ for $1{\times}1cm^2$ and $0.602{\pm}0.0399$ for $0.5{\times}0.5cm^2$. The output factor of MLC open field has shown a maximum 3.8% higher than that of the collimator jaw open field.

Effects of Artificial Light Sources for Night Break on Floral Induction and Growth in Perilla ocymoides L. (광질 조절용 전구를 이용한 야파가 잎들깨의 개화 및 생육에 미치는 영향)

  • Choi, Young-Whan;Son, Beung-Gu;Kang, Jum-Soon;Lee, Yong-Jae;Park, Hyean-Cheal;Kim, Keun-Ki;Kim, Yong-Chul;Choi, In-Soo;Lee, You-Jin;Shin, Woo-Jung;Park, Young-Hoon
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.150-156
    • /
    • 2008
  • The influences of night break by costly artificial light sources were investigated on the photo-morphogenesis and growth of leafy perilla (Perilla ocymoides L.). The irradiation of red, blue, and three-colored light for night break significantly increased the stem length and stem diameter compared to dark. Three-colored light gave the highest fresh and dry weight of stem, followed by red and blue light. Floral induction was suppressed up to 100 days after the night break, by red and three-colored light, but the plants grown under the dark or treated with blue light showed 85% and 31% flowering rate, respectively. The time needed for floral induction after night break was 60 days in dark and 80 days in blue light. The number of leaf, leaf area, and fresh weight per plant were the highest in red and three-colored light night break, followed by blue light and dark. The photosynthetic rate observed 80 days after night break was the highest in red light, followed by blue and three-colored light. A low light compensation point of $20\;{\mu}mol\;m^{-2}{\cdot}s^{-1}$ was observed in three-colored light, while red and blue light tended to show higher measurements.

Effects of X-ray Irradiation on the Survival Rate and Weight of the Rhinoceros Beetle Larvae (X선 이 장수풍뎅이 유충의 체중과 생존율에 미치는 영향)

  • Lee, Won-Jeong;Lim, Dong-Hwan;Park, Jeong-Soon;Sim, Yeung-Eun;Jeong, Yoo-Jin;Kim, Jeong Ho;Yoo, Se Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.271-277
    • /
    • 2020
  • The Purpose of this study was to examine the survival rate and weight of rhinoceros beetle larvae by irradiating X-rays which are most commonly used in diagnosing and treating for diseases. Subjectts and Methods: In early April 2019, the rhinoceros beetle larvae 41 were classified into two groups as control group (11 larvae) and irradiated group (10 Gy, 20 Gy, 30 Gy, each 10 larvae). The irradiated group was exposed by 6 MV X-ray using linear accelerators (Clinac IS, VERIAN, USA) at the University Hospital in Daejeon (Source-surface distance 96 cm, field size 18 × 10 cm, dose rate 600 MU/min), after environmental adaptation for 3 days (temperature 20.6℃, humidity 64.3%). The survival rate and weight were measured weekly after irradiating X-ray. All statistical analyses were performed using the SPSS ver. 22.0 (Chicago, IL, USA). The weight was analysed by Independent T-test, by cross-sectional analysis for survival rates between control and X-ray irradiated groups. Also, the correlation between dose and weight was analyzed by Spearman test. In 3-week after irradiating X-ray, weight was significant difference between control group and irradiated group (10 Gy or 20 Gy, p < 0.05; and 30 Gy, p < 0.01) with increasing weight in all experimental groups. In 14-week, weight was increased in the control group, but decreased in irradiated group. weight was significant difference between control group and irradiated group. The survival rate in 3-week was decreased rapidly in all experimental group except 10 Gy, to 4-week in irradiated group. The control group had no change in survival rate 54.5% from 3-week to 14-week. From the 3-week, it showed lower survival rate with increasing radiation dose in irradiated group. In 19-week, survival rate of control group and 10 Gy was 45.4% and 30.0% respectively, all died in 20 Gy and 30 Gy. Weight was significantly negative correlated with radiation dose as longer time after irradiating X-ray. The weight and survival rate of rhino beetle larvae is affected by irradiating X-rays, weight and survival rate decreased more in higher dose.