• 제목/요약/키워드: Irradiation test

검색결과 689건 처리시간 0.025초

An Improved Photovoltaic System Output Prediction Model under Limited Weather Information

  • Park, Sung-Won;Son, Sung-Yong;Kim, Changseob;LEE, Kwang Y.;Hwang, Hye-Mi
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1874-1885
    • /
    • 2018
  • The customer side operation is getting more complex in a smart grid environment because of the adoption of renewable resources. In performing energy management planning or scheduling, it is essential to forecast non-controllable resources accurately and robustly. The PV system is one of the common renewable energy resources in customer side. Its output depends on weather and physical characteristics of the PV system. Thus, weather information is essential to predict the amount of PV system output. However, weather forecast usually does not include enough solar irradiation information. In this study, a PV system power output prediction model (PPM) under limited weather information is proposed. In the proposed model, meteorological radiation model (MRM) is used to improve cloud cover radiation model (CRM) to consider the seasonal effect of the target region. The results of the proposed model are compared to the result of the conventional CRM prediction method on the PV generation obtained from a field test site. With the PPM, root mean square error (RMSE), and mean absolute error (MAE) are improved by 23.43% and 33.76%, respectively, compared to CRM for all days; while in clear days, they are improved by 53.36% and 62.90%, respectively.

Development of a Thermoelectric Cooling System for a High Efficiency BIPV Module

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.187-193
    • /
    • 2010
  • This paper proposes a cooling system using thermoelectric elements for improving the output of building integrated photovoltaic (BIPV) modules. The temperature characteristics that improve the output of a BIPV system have rarely been studied up to now but some researchers have proposed a method using a ventilator. The efficiency of a ventilator depends mainly on the weather such as wind, irradiation etc. Because this cooling system is so sensitive to the velocity of the wind, it is unable to operate in the nominal operating cell temperature (NOCT) or the standard test condition (STC) which allow it to generate the maximum output. This paper proposes a cooling system using thermoelectric elements to solve such problems. The temperature control of thermoelectric elements can be controlled independently in an outdoor environment because it is performed by a micro-controller. In addition, it can be operated around the NOCT or the STC through an algorithm for temperature control. Therefore, the output of the system is increased and the efficiency is raised. This paper proves the validity of the proposed method by comparing the data obtained through experiments on the cooling systems of BIPV modules using a ventilator and thermoelectric elements.

중성자(中性子) 방사화(放射化) 분석법(分析法)에 의(依)한 한국인(韓國人) 간장중(肝臟中)의 비소(砒素) 및 Vitamin제제중(製劑中)의 금속(金屬)(CU, Mn)의 정량(定量) (Determination of Arsenic in Korean human liver and manganese, copper in Vitamin prepartions by neutron action analysis)

  • 오수창
    • Journal of Pharmaceutical Investigation
    • /
    • 제4권4호
    • /
    • pp.17-25
    • /
    • 1974
  • 1. Neutron acivation analysis of arsenic contained in Korean human liver was studied in the view point of forensic chemistry, using 12 corpses. A sample of 1g was irradiated for 30 mins. in a neutron flux of $1.2{\times}10^{12}n/cm^2/sec$, followed by nitric-sulfuric acid digestion and then by Gutzeit separation. Radio activity was detected by it's scintillation counter. The arsenic content in the liver was found to be $0.01{\mu}g/g$ to $0.15{\mu}g/g$. 2. A rapid and convenient method for the radiochemical determination of minerals by neutron activation analysis was established. After neutron irradiation to the standard soln. of Cu and Mn in pneumatic tube (neutron flux : $1.2{\times}10^{12}n/cm^2/sec$), Cu and Mn were determined by estimating the ratio of the widths under energy peak area in ${\gamma}-ray-spectrogram$. When the standard soln. of Mn and Cu is irradiated for 15 mins. to 18 hrs., recovery test shows that the relative errors are 5.1% and 4.5% for copper and manganese, respectively.

  • PDF

인공관절에 사용되는 UHMWPE의 내마모성 향상에 관한 연구 (An enhancement in wear property of UHMWPE used in joint prosthesis)

  • 김경태;이창우;최재봉;최귀원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.3-6
    • /
    • 1996
  • The Ultra-high molecular weight polyethylene (UHMWPE) is exclusivity used as the articulation component with metal or ceramic materials in artificial joint prosthesis because of its good mechanical properties. In the long term however, wear of UHMWPE causes complex problems and hence causes loosening of He prosthesis. In this study, we tried to enhance the wear property of UHMWPE by attaching a hydrophilic graft on the UHMWPE surface and by improving surface hardness without deteriorating the mechanical properties of UHMWPE. This was achieved by ion implantation and by ${\gamma}$-irradiation to the surface in acrylic acid solution and by photo-polymerization in divinylbenzen (DVB), diallysophthalate (DAIP) solution. The wear test was performed by a wear testing machine of ball-on-disk type devised by the authors. The UHMWPE with hydrophlic surface and increased surface hardness developed by above treatments showed less volumetric wear.

  • PDF

영상장치 기반 정밀치료용 레이저 수술기의 성능 평가 방법 개발 (Study of Efficiency Test Evaluations Method for Imaging Device Based Laser Equipment)

  • 김대창;이승봉;정재훈;김성민
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권6호
    • /
    • pp.230-234
    • /
    • 2019
  • Medical laser equipment using optical energy is used to surgery and treat diseases by destroying and removing tissue. Domestic laser equipment has been used steadily in the skin and cosmetics sectors and has been changed to radiate high-power energy in a wide range to shorten patient treatment time. However, side effects such as burns and damage of normal tissues occurred. To solve this problem, techniques for detecting lesions using an imaging device and selectively radiating the laser have been developed. In this study, we proposed an evaluation method to evaluate the safety and performance of target detection accuracy, laser irradiation accuracy and motion protection device technology derived from product analysis and investigation. Finally, the validity of the evaluation method was evaluated by evaluating the imaging device based laser equipment as the proposed evaluation method.

Argon 이온 레이저 중합에 의한 Composite resin의 물성에 관한 연구 (AN INVESTIGATION ON THE CHARACTERIZATION OF COMPOSITE RESIN POLYMERIZED BY THE USE OF AN ARGON ION LASER)

  • 조현경;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.69-82
    • /
    • 1992
  • An experimental investigation of the physical properties of light curing composite resin P-50 was performed, in which an argon ion laser beam was irradiated. The physical and mechanical properties of laser polymerized composite resin were determined by measuring the compressive strength, diametral tensile strength, curing depth and microhardness depending upon the experimental conditions such as the laser irradiation time(10sec, 20sec, 30sec) and laser power(300mW, 500mW, 1000mW). These observations were compared with a conventional visible light curing technique. In addition, to evaluate the marginal adaptation, Class V cavity was prepared on the buccal or lingual surface of the extracted premolar and filled with P-50 light curing resin. The test samples were irradiated with both light sources so that the interface between the restoration and the tooth structure were observed under scanning electron microscope. The most of physical and mechanical properties of the laser cured resin showed a remarkable improvement than those treated with the conventional light source, while the observations with the scanning electron microscope provided no significant difference for two polymerized sources. From the results in the experiment it appears that the potential of an argon ion laser is of important value of the use in the polymerization of composite resin.

  • PDF

Study on Bead-based Microbiochip and Analytical System for Protein Detection

  • Kim, Min-Soo;Chung, Woo-Jae;Cho, Su-Hyung;Park, Sung-Soo;Kim, Byung-Gee;Lee, Young-Sik;Kim, Yong-Kweon
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.60-63
    • /
    • 2002
  • This paper presents bead-based microbiocihps to detect and separate target proteins. Micro beads coated with capture proteins were introduced into a microchamber, and target proteins flowing across the chamber were bound and concentrated. The chip was connected with an external fluid system. Bead surfaces were double-coated with photo-cleavable linkers and capture proteins. The proteins bound on the beads were photo-separated under UV irradiation, and excited to be measured in fluorescence. $38{\sim}50{\mu}m$ sized polystyrene beads were used. SOGs(silicon-on-glass) were used to fabricate the microchip having glasses bonded on both sides. 100 ${\mu}m$ thick silicon channel was formed through silicon deep RIE process. The upper glass cover had holed through to have inlets and outlets fabricated by powder-blastings. In this study, biotin and streptavidin were used as capture proteins and detection proteins, respectively. The protein mixtures of streptavidin, HSA(human serum albumin) and ovalbumin were applied for selective detection test.

  • PDF

Flame-retardant Coating of Cotton Fabric via UV curing of DMEP

  • Jang, Jin-Ho;Kim, Young-Min;Jeong, Yong-Kyun;Nam, Young Sik
    • 한국염색가공학회지
    • /
    • 제19권5호
    • /
    • pp.1-7
    • /
    • 2007
  • A new UV-curable coating was carried out to impart the flame-retardant property to cotton fabric using Bis[2-(methacryloyloxy)ehtyl]phosphate(DMEP) and 2-hydroxy-2-methyl-1-phenyl-propan-l-one(HMPP) as a UV-curable monomer and a photoinitiator, respectively. The cotton fabrics were applied with various amounts of DMEP and HMPP via padding and UV irradiation, and the optimal concentrations of DMEP and HMPP in the formulation were 40%(w/w) and 7%omp respectively. A limiteed oxygen index(LOI) up to 28.9 was obtained for the UV-cured fabric, which may occur through a condensed phase mechanism as verified by the increased residue number with increased application level. The characterization of the UV-cured coating was made by IR analysis, thermo-gravimetric analysis, LOI test, and scanning electron microscopy.

용융탄산염 연료전지 양극용 다공성 cermet 전극제조에 관한 연구 (A study on the fabrication of porous cermet electrode for molten carbonate fuel cell anode)

  • 이규환;장도연;김만;강성군
    • 한국표면공학회지
    • /
    • 제26권6호
    • /
    • pp.291-298
    • /
    • 1993
  • In order to substitute for porous nickel anode in Molten Carbonate Fuel Cell(MCFC), porous cermet elec-trode was fabricated with Ni and Ni-P coated ceramic powder. Ni and Ni-P were coated by electroless plat-ing method in the nickel solution containing of hydrazine and sodium hypophosphate as a reducing agent. The plating solution was stirred by air and mechanical agitator. Ultrasonic irradiation was applied to the plating bath to improved the effect of agitation and coating speed. Electorde was formed by pressing method and doc-tor blade method followed by sinterd at$ 800^{\circ}C$ for 6 hours in H2 environment. Anode performance test carried out by potentiodynamic polarization technique in the MCFC operating condition and 154-161mA/$\textrm{cm}^2$ as ob-tained as a anode current density at the+100mV overpotential.

  • PDF

LARGE SCALE FINITE ELEMENT THERMAL ANALYSIS OF THE BOLTS OF A FRENCH PWR CORE INTERNAL BAFFLE STRUCTURE

  • Rupp, Isabelle;Peniguel, Christophe;Tommy-Martin, Michel
    • Nuclear Engineering and Technology
    • /
    • 제41권9호
    • /
    • pp.1171-1180
    • /
    • 2009
  • The internal core baffle structure of a French Pressurized Water Reactor (PWR) consists of a collection of baffles and formers that are attached to the barrel. The connections are done thanks to a large number of bolts (about 1500). After inspection, some of the bolts have been found cracked. This has been attributed to the Irradiation Assisted Stress Corrosion Cracking (IASCC). The $Electricit\acute{e}$ De France (EDF) has set up a research program to gain better knowledge of the temperature distribution, which may affect the bolts and the whole structure. The temperature distribution in the structure was calculated thanks to the thermal code SYRTHES that used a finite element approach. The heat transfer between the by-pass flow inside the cavities of the core baffle and the structure was accounted for thanks to a strong thermal coupling between the thermal code SYRTHES and the CFD code named Code_Saturne. The results for the CP0 plant design show that both the high temperature and strong temperature gradients could potentially induce mechanical stresses. The CPY design, where each bolt is individually cooled, had led to a reduction of temperatures inside the structures. A new parallel version of SYRTHES, for calculations on very large meshes and based on MPI, has been developed. A demonstration test on the complete structure that has led to about 1.1 billion linear tetraedra has been calculated on 2048 processors of the EDF Blue Gene computer.