• Title/Summary/Keyword: Irradiation test

Search Result 680, Processing Time 0.03 seconds

Effect of Intravenous He-Ne Laser Irradiation on Cholesterol Value of Hyperlipidemia Patients (정맥 혈관내 He-Ne 레이저 조사가 고지혈증 환자의 지질 수치에 미치는 영향)

  • Ryu, Hyun-Hee;Son, Ji-Young;Lee, Seoung-Geun;Yun, Jong-Min;Lee, Gi-Sang
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.86-92
    • /
    • 2004
  • In order to determine the effect of intravenous He-Ne laser irradiation, values of serum total cholesterol, Triglyceride, LDL-cholesterol and HDL-cholesterol were measured. Twenty three patients with hyperlipidemia who visited Gunpo Oriental Medical Center of Wonkwang University were treated with He-Ne laser irridiation and analyzed by Paired T-test of SPSS program. The following results were obtained : The serum Total cholesterol and LDL-cholesterol of patients treated with He-Ne laser irradiation showed a significant(P<0.05) decrease, and the serum Triglyceride and HDL-cholesterol of patients treated with He-Ne laser irradiation showed no significant(P<0.05) effects.

  • PDF

Detection of Irradiated Model Food Containing Salt by Thermoluminescence Measurement

  • Chung, Hyung-Wook;Kwon, Joong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.1
    • /
    • pp.22-26
    • /
    • 1998
  • Model food containing common salt(NaCl) was subjected to the thermoluminescene(TL) detection whether it is irradiated or not. Salt irradiated with $^60Co$-gamma ray and electron beam exhibited a characteristic TL gowcurve depending on the irradiation dose, showing major peaks at $206^{\circ}C$ and $326^{\circ}C$. The intensity of TL glowcurves was directly proportional to the irradiated doses regardless of irradiation sources at each concentration of salt. A high correlation coefficient was observed for irradiated salt between the irradiation doses and the corresponding TL responses. At the same dose, the intensity of TL glowcurve increased as the concentration of salt increased in the test sample. TL glowcurves of nonirradiated salt and irradiated model food without salt were negligible and similar to a baseline . However, irradiated model food containing salt gave rise to a characteristic TL glowcurve with two major peaks at about $240^{\circ}C$ and $300^{\circ}C$, respectively. The results showed that salt played a role as an internla as well as external indicator in TL measurements, indicating that TL will be applicable to other condiments and spices with salt for their detection whether they are irradiated or not.

  • PDF

A Study on the Atomization Characteristics of the Ultrasonic-Energy-Irradiation High Viscosity Biodiesel Blended Fuel (초음파 에너지 조사 고 점도 바이오디젤 혼합연료의 미립화 특성에 관한 연구)

  • Song Yong-Seek;Yang In-Kwon;Kim Bong-Seock;Ryu Jung-In
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.235-241
    • /
    • 2004
  • This experiment was undertaken to investigate the atomization characteristics of the high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Test fuels were conventional diesel fuel and biodiesel one. We compared to the characteristics of viscosity and surface tension, SMD between high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Sauter mean diameter was measured under the variation of the spray distance. Viscosity and surface tension were measured under the variation of the time trace. To measure the droplet size, we used the Malvern system 2600c. Droplet size distribution was analyzed from the result data of Malvern system. Through this experiment, we found that the condition of the ultrasonic energy irradiation situation had smaller Sauter mean diameter of droplet, viscosity and surface tension than those of the conventional situation.

Simulating Nuetron Irradiation Effect on Cyclic Deformation and Failure Behaviors using Cold-worked TP304 Stainless Steel Base and Weld Metals (냉간가공된 TP304 스테인리스강 모재와 용접재를 이용한 반복 변형 및 손상 거동에 미치는 중성자조사 영향 모사)

  • Kim, Sang Eun;Kim, Jin Weon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.2
    • /
    • pp.58-67
    • /
    • 2020
  • This study presents cyclic stress-strain and tensile test results at room temperature (RT) and 316℃ using cold-worked TP304 stainless steel base and weld metals. By comparing the cyclic hardening/softening behavior and failure cycle of cold-worked materials with those of irradiated austenitic stainless steels, the feasibility of simulating the irradiation effect on cyclic deformation and failure behaviors of TP304 stainless steel base and weld metals was investigated. It was found that, in the absence of strain-induced martensite trasformation, cold-working could properly simulate the change in cyclic hardening/softening behavior of TP304 stainless steel base and weld metals due to neutron irradiation. It was also recognized that cold-working could adequately simulate the reduction in failure cycles of TP304 stainless steel base and weld metals due to neutron irradition in the low-cycle fatigue region.

Influence and analysis of a commercial ZigBee module induced by gamma rays

  • Shin, Dongseong;Kim, Chang-Hwoi;Park, Pangun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1483-1490
    • /
    • 2021
  • Many studies are undertaken into nuclear power plants (NPPs) in preparation for accidents exceeding design standards. In this paper, we analyze the applicability of various wireless communication technologies as accident countermeasures in different NPP environments. In particular, a commercial wireless communication module (WCM) is investigated by measuring leakage current and packet error rate (PER), which vary depending on the intensity of incident radiation on the module, by testing at a Co-60 gamma-ray irradiation facility. The experimental results show that the WCMs continued to operate after total doses of 940 and 1097 Gy, with PERs of 3.6% and 0.8%, when exposed to irradiation dose rates of 185 and 486 Gy/h, respectively. In short, the lower irradiation dose rate decreased the performance of WCMs more than the higher dose rate. In experiments comparing the two communication protocols of request/response and one-way, the WCMs survived up to 997 and 1177 Gy, with PERs of 2% and 0%, respectively. Since the request/response protocol uses both the transmitter and the receiver, while the one-way protocol uses only the transmitter, then the electronic system on the side of the receiver is more vulnerable to radiation effects. From our experiments, the tested module is expected to be used for design-based accidents (DBAs) of "Category A" type, and has confirmed the possibility of using wireless communication systems in NPPs.

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.