• 제목/요약/키워드: Irradiation swelling

검색결과 110건 처리시간 0.027초

Hydrogen Bonding Effect on γ-Ray Irradiated Poly(vinyl alcohol) Hydrogels in Different Drying Conditions

  • Gwon, Hui-Jeong;Jo, Sun Young;Park, Eun Ji;Shin, Young Min;Choi, Jong-Bae;Park, Jong-Seok;Lim, Youn-Mook;Nho, Young-Chang;Kang, Phil Hyun
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.89-94
    • /
    • 2012
  • Three-dimensional network hydrogels were prepared by ${\gamma}$-irradiation of aqueous solutions of poly(vinyl alcohol) (PVA) and glycerol (Gly). Oven-drying was used to measure the gel fraction (G), hydration (H) or swelling behavior (S) of the prepared hydrogels. This study made a hypothesis that hydrogen bonds due to addition of glycerol and change of dry states such as freeze-drying (FD), room-drying (RD) and oven-drying (OD) acts on the G, H, and S. Interesting results on the hydrogen bonding effect in the prepared hydrogels are monitored at different drying conditions. The FD samples have a higher G values with increase in glycerol content as compared with the OD and RD samples. The formation of strong hydrogen bonding network among Gly molecules and hydrogel matrix was considered as the main driving force, resulting in the changes in the G, H, and S of the hydrogels under different drying conditions.

Thermo-mechanical coupling behavior analysis for a U-10Mo/Al monolithic fuel assembly

  • Mao, Xiaoxiao;Jian, Xiaobin;Wang, Haoyu;Zhang, Jingyu;Zhang, Jibin;Yan, Feng;Wei, Hongyang;Ding, Shurong;Li, Yuanming
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.2937-2952
    • /
    • 2021
  • A typical three-dimensional finite element model for a fuel assembly is established, which is composed of 16 monolithic U-10Mo fuel plates and Al alloy frame. The distribution and evolution results of temperature, displacement and stresses/strains in all the parts are numerically obtained and analyzed with a self-developed code of FUELTM. The simulation results indicate that (1) the out-of-plane displacements of Al alloy side plates are mainly attributed to the bending deformations; (2) enhanced out-of-plane displacements appear in fuel plates adjacent to the outside Al plates, which results from the occurred bending deformations due to the applied constraints of outside Al plates; (3) an intense interaction of fuel foil with the cladding occurs near the foil edge, which appears more heavily in the fuel plates adjacent to the outside Al plates. The maximum first principal stresses in the fuel foil are similar for all the fuel plates and appear near the fuel foil edge; while, the through-thickness creep strains of fuel foil in the fuel plate near the central region of fuel assembly are larger, and the induced creep damage might weaken the fuel skeleton strength and raise the fuel failure risk.

상공정맥 증후군 -Dacron & Nylon 환치수술 2예- (Superior Vena Cava Syndrome -2 Bypass Graft Cases-)

  • 김정석
    • Journal of Chest Surgery
    • /
    • 제2권1호
    • /
    • pp.65-72
    • /
    • 1969
  • Superior Vena Cava Syndrome: Dacron and Nylon graft between the left innominate vein and the right atrial appendage. Two cases with typical superior vena cave syndrome treated by by-pass graft between the left innominate vein and the right atrial apepndage were presented. One of them was a 58 year old farmer who suffered from marked swelling of the neck and upper half of body, the other was a 50 years old government employee who had acutely progressive symptoms of superior vena cave obstruction. Both of cases revealed that [1] cubitel venous pressure was markedly increased. [2] tumors were noted in the posterior mediastinum by laminography. [3] preoperative cavogram showed the occlusion of superior vena cava and marked collaterals. Dacron and Nylon graft were inserted between the left innominate vein and the right atrial appendage. Postoperatively, the symptoms were relieved markedly, showing edema free face and decreased cubital venous pressure. Postoperative cavogram showed patent graft. Histologically the first case was diagnosed as squamous cell carcinoma and the second as undifferentiated carcinoma, originated probably from bronchus. Total doses of 3150 r X-ray irradiation and 5000 mg of 5-FU were administered in each cases. The first case expired 11 months postoperatively without recurrence of superior vena cave obstruction symptom and the second case is living now without obstruction signs, 4 months after by-pass operation.

  • PDF

Albumin Release from Biodegradable Hydrogels Composed of Dextran and Poly(Ethylene Glycol) Macromer

  • Kim, In-Sook;Jeong, Young-Il;Kim, Do-Hoon;Lee, Yun-Ho;Kim, Sung-Ho
    • Archives of Pharmacal Research
    • /
    • 제24권1호
    • /
    • pp.69-73
    • /
    • 2001
  • Biodegradable hydrogels based on glycidyl methacrylate dextran (CMD) and dimethacrylate poly(ethylene glycol) (DMP) were proposed for colon-specific drug delivery. GMD was synthesized by coupling of glycidyl methacylate with dextran in the presence of 4-(N, N-dimethylamino)pyridine (DMAP) using dimethylsulfoxide as a solvent. Methacrylate-terminated poly (ethylene glycol) (PEG) macromer was prepared by the reaction of PEG with methacryloyl chloride. CMD/DMP hydrogels were prepared by radical polymerization of phosphate buffer solution (0.1 M, pH 7.4) of GMD and DMP using ammonium peroxydisulfate (APS) and UV as initiating system. The synthetic GMD, DMP and GMD/DMP hydrogels were characterized by fourier transform infrared (FT-lR) spectroscopy. The FITC-albumin loaded hydrogels were prepared by adding FITC-albumin solution before UV irradiation. Swelling capacity of GMD/DMP hydrogels was controlled not only by molecular weight of dextran, but also by incorporation ratio of DMP Degradation of the hydrogels has been studied in vitro with dextranase. FITC-albumin release from the GMD/DMP hydrogels was affected by molecular weight of nextran and the presence of dextranase in the release medium.

  • PDF

UV 경화형 키토산/지방족 폴리에스터 Hydrogel IPN 제조 및 약물투과 (Synthesis, Properties and Permeation of Solutes through Hydrogels based on Poly(ethylene glycol)-co-Poly(lactones) diacrylate Macromers and Chitosan)

  • 조성민;김소연;이영무;성용길;조종수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.229-230
    • /
    • 1998
  • Triblock copolymers from poly(ethylene glycol) (PEG) and D,L-lactide or $\varepsilon$-carprolactone were synthesized to prepare semi-interpenetrating polymer network (semi-IPN) with chitosan by U.V. irradiation method. Then, solute permeation through these semi-IPNs hydrogels were investigated. The structures of semi-IPNs were confirmed by FT-IR spectroscopy and wide angle X-ray diffractometer (WAXD). Equilibrium water content (EWC) of these hydrogels was in the range of 67-75%. The crystallinity, thermal properties and mechanical properties of semi-IPNs hydrogels were studied. All the hydrogels revealed a remarkable decrease in crystallinity as compared with PEG macromer itself. The tensile strengths of semi-IPNs hydrogels in dry state were rather high, but those of hydrogels in wet state decreased drastically. The permeabilities of solutes of hydrogels followed the swelling behaviors and were regulated by solute size.

  • PDF

방사선을 이용하여 제조한 poly(vinyl alcohol)/poly(acrylic acid) 하이드로젤의 제조 및 특성 (Preparation and Characterization of Poly(vinyl alcohol)/Poly(acrylic acid) Hydrogel by Radiation)

  • 박종석;김현아;최종배;권희정;임윤묵;노영창
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.377-382
    • /
    • 2011
  • Poly(vinyl alcohol) (PVA) is an interesting material with good biocompatibility, high elasticity and hydrophilic chacrateristics. In this study, crosslinked hydrogels based on PVA, and poly(acrylic acid) (PAAc) were prepared by gamma-ray irradiation. PVA and PAAc powders were dissolved in deionized water, and then irradiated by a gamma-ray with a radiation dose of 50 kGy to make hydrogels. The hydrogels were then annealed in an oven at $120^{\circ}C$ for 10 min, 30 min and 50 min under nitrogen atmosphere. The properties of a hydrogel such as gel fraction, swelling behavior, thermogravimetric analysis (TGA) and adhesive strength as a function of PAAc content and annealing time were investigated. The gel fraction decreases with decreasing PAAc content and increasing annealing time. The thermal behaviors have shown different patterns according to the annealing time. The adhesive strength increases with increasing PAAc content.

Theoretical studies on the stabilization and diffusion behaviors of helium impurities in 6H-SiC by DFT calculations

  • Obaid Obaidullah;RuiXuan Zhao;XiangCao Li;ChuBin Wan;TingTing Sui;Xin Ju
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2879-2888
    • /
    • 2023
  • In fusion environments, large scales of helium (He) atoms are produced by a radical transformation along with structural damage in structural materials, resulting in material swelling and degradation of physical properties. To understand its irradiation effects, this paper investigates the stability, electronic structure, energetics, charge density distribution, PDOS and TDOS, and diffusion processes of He impurities in 6HSiC materials. The formation energy indicates that a stable, favorable position for interstitial He is the HR site with the lowest energy of 2.40 eV. In terms of vacancy, the He atom initially prefers to substitute at pre-existing Si vacancy than C vacancy due to lower substitution energy. The minimum energy paths (MEPs) with migration energy barriers are also calculated for He impurity by interstitial and vacancy-mediated diffusion. Based on its calculated energy barriers, the most possible diffusion path includes the exchange of interstitial and vacancy sites with effective migration energies ranging from 0.101 eV to 1.0 eV. Our calculation provides a better understanding of the stabilization and diffusion behaviors of He impurities in 6H-SiC materials.

자외선에 의한 피부반응 (Effects of Ultraviolet Radiation on the Skin)

  • 윤재일
    • Journal of Radiation Protection and Research
    • /
    • 제20권3호
    • /
    • pp.181-186
    • /
    • 1995
  • 자외선이 피부에 조사되면 다양한 피부반응을 초래한다. 이러한 반응은 크게 1) 급성 반응과 2) 만성반응으로 나눌 수 있다. 급성반응으로서는 피부가 붉어지는 홍반반응, 피부색이 검어지는 색소반응, 그리고 피부두께의 변화 등을 들 수 있다. 홍반반응은 피부의 주된 세포인 각질형 세포를 비롯하여 진피세포들이 광여하여 진피혈관을 확장시키는 반응을 말한다. 홍반반응은 자외선의 파장, 광량, 피부의 조건, 환경조건 등에 따라 달라지며 피부에는 각질형성세포가 변형된 일광화상세포가 출형한다. 홍반반응은 가장 흔한 주된 반응이나 그 기전에는 명확하지 않은 점이 아직도 많이 있다. 색소반응은 멜라닌세포가 관여하는 반응으로서 자외선 조사 후 즉시 피부가 검어지는 즉시세포침착과 수일 후 검어지는 지연색소침착으로 나눌 수 있다. 색소반응과 피부두께의 변화 등은 자외선 조사로부터 몸을 보호하기 위한 방어작용의 일종이다. 자외선 조사에 의한 만성반응으로는 광노화현상과 광 발암현상을 들 수 있다. 광노화란 장기간에 걸친 광노출로 인한 피부의 노화를 말하며 생리적인 노화와는 임상적, 조직학적으로 다른 점이 많다. 자외선의 장기노출은 피부암을 발생시키는 중요한 원인의 하나로서 우리나라도 피부암 발생이 점차 증가하고 있다. 서울대학교병원 피부과에서의 피부암 발생빈도는 70년대에는 외래환자의 0.2% 정도였으나 80년대에는 0.4-0.8%를 차지하고 있다. 앞으로 우리나라의 경제성장과 함께 수명의 증가, 레져나 스포츠의 증가, 피부노출의 증가와 함께 오존층 파괴로 인하여 피부에 조사되는 자외선의 절대량의 증가는 자외선에 의한 피부의 급 만성반응을 더욱 증가시킬 것으로 예상되며 이에 대한 적절한 대책이 요구된다.

  • PDF

방사선을 이용한 전기 활성 PAAc/PVA/PEG 하이드로겔 소프트 액추에이터의 제조 및 구동 특성 분석 (Synthesis of Electroactive PAAc/PVA/PEG Hydrogel Soft Actuator by Radiation Processing and Their Dynamic Characteristics)

  • 신예린;김소연
    • 공업화학
    • /
    • 제30권6호
    • /
    • pp.698-706
    • /
    • 2019
  • 지난 수십 년 동안, 외부 자극에 대한 응답성이 우수하면서도 인체에 적용할 수 있는 소프트 액추에이터 개발을 위한 많은 노력이 이어졌다. 본 연구에서는 동역학적 정밀 제어가 가능한 의료용 소프트 액추에이터를 개발하기 위해, 유해한 화학적 첨가제나 개시제 없이 방사선을 이용하여 전기 자극 반응성과 물리적 특성이 우수한 3차원 가교 구조의 poly(acrylic acid) (PAAc)/poly(vinyl alcohol) (PVA)/poly(ethylene glycol) (PEG) 하이드로겔을 합성하였다. 방사선 조사 후, 모든 하이드로겔은 75% 이상의 겔 분율을 나타내었고, 표면 반사 적외선 분광법을 통해 PAAc/PVA/PEG 하이드로겔이 성공적으로 합성되었음을 확인하였다. 또한 PAAc/PVA/PEG 하이드로겔의 겔 분율, 평형 수분 함량, 압축 강도를 측정하여 감마선의 총 조사 선량과 구성 성분의 함량비 조절에 따른 하이드로겔의 물리적 특성 변화를 확인하였다. 조사된 감마선의 선량이 증가하거나 poly(ethylene glycol) diacrylate (PEGDA)의 함량이 많을수록 PAAc/PVA/PEG 하이드로겔은 높은 가교 밀도와 우수한 기계적 강도를 나타내었다. 또한 PAAc/PVA/PEG 하이드로겔은 3 V의 저전압에서도 전기적인 자극에 반응하였고, 전기장 하에서 이동성 이온의 움직임에 따른 하이드로겔의 밴딩 거동은 하이드로겔의 가교 밀도, 이온기의 함량, 인가 전압 및 전해질 용액의 이온 농도 등을 조절함으로써 제어할 수 있음을 확인하였다.

Simulation of reactivity-initiated accident transients on UO2-M5® fuel rods with ALCYONE V1.4 fuel performance code

  • Guenot-Delahaie, Isabelle;Sercombe, Jerome;Helfer, Thomas;Goldbronn, Patrick;Federici, Eric;Jolu, Thomas Le;Parrot, Aurore;Delafoy, Christine;Bernaudat, Christian
    • Nuclear Engineering and Technology
    • /
    • 제50권2호
    • /
    • pp.268-279
    • /
    • 2018
  • The ALCYONE multidimensional fuel performance code codeveloped by the CEA, EDF, and AREVA NP within the PLEIADES software environment models the behavior of fuel rods during irradiation in commercial pressurized water reactors (PWRs), power ramps in experimental reactors, or accidental conditions such as loss of coolant accidents or reactivity-initiated accidents (RIAs). As regards the latter case of transient in particular, ALCYONE is intended to predictively simulate the response of a fuel rod by taking account of mechanisms in a way that models the physics as closely as possible, encompassing all possible stages of the transient as well as various fuel/cladding material types and irradiation conditions of interest. On the way to complying with these objectives, ALCYONE development and validation shall include tests on $PWR-UO_2$ fuel rods with advanced claddings such as M5(R) under "low pressure-low temperature" or "high pressure-high temperature" water coolant conditions. This article first presents ALCYONE V1.4 RIA-related features and modeling. It especially focuses on recent developments dedicated on the one hand to nonsteady water heat and mass transport and on the other hand to the modeling of grain boundary cracking-induced fission gas release and swelling. This article then compares some simulations of RIA transients performed on $UO_2$-M5(R) fuel rods in flowing sodium or stagnant water coolant conditions to the relevant experimental results gained from tests performed in either the French CABRI or the Japanese NSRR nuclear transient reactor facilities. It shows in particular to what extent ALCYONE-starting from base irradiation conditions it itself computes-is currently able to handle both the first stage of the transient, namely the pellet-cladding mechanical interaction phase, and the second stage of the transient, should a boiling crisis occur. Areas of improvement are finally discussed with a view to simulating and analyzing further tests to be performed under prototypical PWR conditions within the CABRI International Program. M5(R) is a trademark or a registered trademark of AREVA NP in the USA or other countries.