• 제목/요약/키워드: Irradiation performance

검색결과 484건 처리시간 0.034초

Mechanical performance of additively manufactured austenitic 316L stainless steel

  • Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.244-254
    • /
    • 2022
  • For tensile tests, Vickers hardness tests and microstructure tests, plate-type and box-type specimens of austenitic 316L stainless steels were produced by a conventional machining (CM) process as well as two additive manufacturing processes such as direct metal laser sintering (DMLS) and direct metal tooling (DMT). The specimens were irradiated up to a fast neutron fluence of 3.3 × 109 n/cm2 at a neutron irradiation facility. Mechanical performance of the unirradiated and irradiated specimens were investigated at room temperature and 300 ℃, respectively. The tensile strengths of the DMLS, DMT and CM 316L specimens are in descending order but the elongations are in reverse order, regardless of irradiation and temperature. The ratio of Vickers hardness to ultimate tensile strength was derived to be between 3.21 and 4.01. The additive manufacturing processes exhibit suitable mechanical performance, comparing the tensile strengths and elongations of the conventional machining process.

이중 초음파 조사 시스템에서 진동부 사이의 거리가 초음파 화학 반응에 미치는 영향 (The Effect of Distance between Two Transducers on Sonochemical Reactions in Dual Irradiation Systems)

  • 김은경;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권5호
    • /
    • pp.39-45
    • /
    • 2013
  • Many researchers have studied the effectiveness of ultrasound in chemical and environmental engineering fields including material synthesis, pollutant removal, cleaning, extraction, and disinfection. Acoustic cavitation induced by ultrasound irradiation in aqueous phase can cause various sonophysical and sonochemical reactions without any chemicals. However most of the previous studies focused only on the relationships between ultrasonic conditions and the results of sonochemical reactions in lab-scale sonoreactors. As a results of this, only a few studies have been devoted to design and optimization of industrial scale sonoreactors. In this study, the effect of the distance between two opposite transducer modules on sonochemical reactions was investigated in single and dual irradiation systems (334 kHz) for four distances including 50, 100, 150, and 200 mm using KI dosimetry. It was found that the dual irradiation systems provided higher performance in terms of the zeroth reaction coefficient and the cavitation yield compared to the single irradiation systems. The sonochemiluminescence (SCL) images for the visualization of the cavitation field showed that cavitation active zone was larger and sonochemical reaction intensity was much higher in the dual irradiation system than in the single irradiation system.

Hydrophilic Modification of Polypropylene Hollow Fiber Membrane by Dip Coating, UV Irradiation and Plasma Treatment

  • Kim Hyun-Il;Kim Jin Ho;Kim Sung Soo
    • Korean Membrane Journal
    • /
    • 제7권1호
    • /
    • pp.19-27
    • /
    • 2005
  • PP hollow fiber membrane was hydrophilized by EVOH dip coating followed by low temperature plasma treatment and UV irradiation. EVOH coating attained high water flux without any prewetting but its stability did not guaranteed at high water permeation rate. At high water permeation rate, water flux declined gradually due to swelling and delamination of the EVOH coating layer causing pore blocking effect. However, plasma treatment reduces the swelling, which suppress delamination of the EVOH coating layer from PP support result in relieving the flux decline. Also, UV irradiation helped the crosslinking of the EVOH coating layer to enhance the performance at low water permeation rate. FT-IR and ESCA analyses reveal that EVOH dip coating performed homogeneously through not only membrane surface but also matrix. Thermogram of EVOH film modified plasma treatment and W irradiation show that crosslinking density of EVOH layer increased. Chemical modification by plasma treatment and UV irradiation stabilized the hydrophilic coating layer to increase the critical flux of the submerged membrane.

전자빔 조사에너지에 따른 ITO/ZnO 적층박막의 구조적, 전기적, 광학적 특성 변화 (Effect of Electron Irradiation on the Structural Electrical and Optical Properties of ITO/ZnO Thin Films)

  • 김선경;김대일
    • 열처리공학회지
    • /
    • 제27권5호
    • /
    • pp.225-229
    • /
    • 2014
  • The influence of electron irradiation energy(eV) on the structural, electrical and optical properties of ITO/ZnO bi-layered films prepared with RF magnetron sputtering has been investigated. The ITO/ZnO show the lowest resistivity of $2.8{\times}10^{-4}{\Omega}cm$. The optical transmittance in a visible wave length region also increased with the electron irradiation energy. The film irradiated at 900 eV shows 82---- of optical transmittance in this study. By comparison of figure of merit, it was observed the optical transmittance and electrical resistivity of the films were dependent on the electron irradiation energy and optoelectrical performance of ITO/ZnO film is improved with electron irradiation.

Thoracic Re-irradiation for Locally Recurrent Lung Cancer

  • Aktan, Meryem;Kanyilmaz, Gul;Koc, Mehmet;Aras, Serhat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권11호
    • /
    • pp.5041-5045
    • /
    • 2016
  • Background: Patients with recurrent or progressive lung cancer experience a significant symptom burden, negatively affecting quality of life and reducing life expectancy. Thoracic re-irradiation can be used for palliative treatment to relieve symptoms or as a curative treatment. Methods: Using patient charts, we identified and reviewed 28 cases that had received palliative thoracic re-irradiation for recurrent lung cancer. Results: Before re-irradiation, 32% of patients had stage III non-small cell lung cancer and six had small cell lung cancer. The median interval between treatments was 18.7 months. Median follow-up was 31.2 months from the initial radiotherapy and 5 months after re-irradiation. A better performance status before re-irradiation (<80 vs >80, p=0.09) and a lower overlap 90% isodose (<70 vs >70, p=0.09) showed trends toward improved survival. Grade 1-2 toxicity from re-irradiation was recorded in 12/28 patients, and no grade 3 or 4 acute toxicity was encountered. Conclusion: The role of palliative treatment in survival is not clear but it can provide symptomatic relief in patients, with no high grade toxicity. Further studies with greater patient numbers and longer follow-up times should facilitate determination of the role of this treatment in toxicity and effects on survival.

Effect of Gamma Irradiation on Anti Nutritional Factors and Nutritional Value of Canola Meal for Broiler Chickens

  • Gharaghani, Hossein;Zaghari, Mojtaba;Shahhosseini, Gholamreza;Moravej, Hossein
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권10호
    • /
    • pp.1479-1485
    • /
    • 2008
  • Two completely randomized block design experiments were conducted to evaluate the effect of gamma irradiation processing of canola meal on performance parameters of broiler chicks (Ross 308) and protein quality of canola meal. Protein efficiency ratio (PER) and net protein ratio (NPR) were measured as indices of canola meal protein quality. Samples of canola meal were tested for nutritional value after being irradiated at dose levels 10, 20 and 30 kGy. Glucosinolate content was reduced 40, 70 and 89 percent at irradiation dose levels of 10, 20 and 30 kGy respectively (p<0.01). Percent of erucic acid in total fatty acid content increased 44, 58 and 48% as a function of radiation dose (p<0.01). Dose levels did not affect feed conversion ratio (FCR) and body weight gain of chicks (p>0.05). Liver weight was decreased by irradiation dose (p<0.05). The same trend was observed for kidney weights, but this trend was not significant (p>0.05). Gamma irradiation processing of canola meal had no significant effect on $T_3$ level in blood of chickens that consumed canola meal, but $T_4$ level of chicken blood at the 30 kGy dose decreased significantly (p<0.05). PER and NPR were not affected by radiation dose level (p>0.05). Gamma irradiation seems to be a good procedure to improve the nutritional quality of canola meal.

환형소결체 하나로 조사시험용 무계장 리그의 차압 및 유동유발 진동시험 (Pressure Drop and Flow-Induced Vibration Test for the HANARO Non-instrumented Irradiation Test Rig of Annular Fuel Pellet)

  • 이강희;김대호;방제건
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.281-286
    • /
    • 2007
  • Needs of fuel's performance evaluation for the dual-cooled fuel pellet (annular shape) necessitate the irradiation test in the test reactor. Irradiation test rig for the HARARO reactor, which is a special-purposed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this paper, pressure drop and flow-induced vibration test for the newly developed non-instrumented test rig were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin. The spectral response characteristics of the flow-induced vibration of the test rid were also discussed.

  • PDF

폴리이미드막에 직선편광된 자외선조사를 이용한 TN-LCD의 전기광학특성의 평가 (Electro-optical performance of TN-LCD using linearly polarized UV light irradiation on po1ymide surface)

  • 서대식;이창훈;이정호;문학룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.109-112
    • /
    • 1998
  • In this paper, we studied on electro-optical (EO) characteristics of photo-aligned twisted nematic (TN)-LCD. We obtained that uniform LC alignment in TN-LCD with linearly polarized ultraviolet (LPUV) light irradiation on polyimide (PI) surface increases according to increasing irradiation time for 10 to 60 min. The voltage-transmittance and response time characteristics of photo-aligned TN-LCD with UV light irradiation time of 60 min were almost same in comparison with conventional TN-LCD were observed. From the results, we suggest that photo-aligned TN-LCD with LPUV light irradiation on PI surface is useful in applying LCD as for rubbing-free treatment method.

  • PDF

경사진 자외선 조사를 이용한 TN-LCD의 전기광학 특성 (Electro-optical performance of TN-LCD wish oblique UV light irradiation on polyimide surface)

  • 서대식;박두석;한정민;황율연;박태규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.113-116
    • /
    • 1998
  • In this paper, we studied the electro-optical(EO) performance of photo-aligned twisted nematic(TN)-liquid crystal display(LCD) with oblique non-polarized ultraviolet(UV) light irradiation on polyimide(Pl) surface. We observed that the voltage-transmittance and response time characteristics of photo-aligned TN-LCD is almost same compared to conventional TN-LCD. Also, we observed that the voltage-holding-ratio(VHR) of photo-aligned TN-LCD is almost same compared to conventional TN-LCD.

  • PDF

흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화 (Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray)

  • 김용;서태범;강용혁
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.