• Title/Summary/Keyword: Irradiation Design

Search Result 293, Processing Time 0.023 seconds

Ecofriendly Antimicrobial Hair Coloration Using Sargassum fusiforme Extract (톳 추출액을 이용한 친환경 항균성 모발 염색)

  • Park, Seong-Jin;Kim, Kang-In;Ko, Ji-Min;Kim, A-Hyun;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.32 no.1
    • /
    • pp.38-43
    • /
    • 2020
  • To overcome the harmful effects caused by conventional oxidative hair dyes, natural colorants becomes more popular in the hair dyeing. By extracting Sagassum fusiforme powders with aqueous alkaline solution as a solvent at 130℃ for 60 minutes, a fucoxanthin concentration of up to 216㎍/ml can be obtained. UV/Vis analysis was used to prove the presence of fucoxanthin in the extract powder. A K/S value of 23.8 can be obtained when wool fabrics were dyed with the extract at 120℃ for 60 minutes under pH 2. The color fastness properties of the dyed wool fabrics were very good as indicated by rating 4 for laundering(color change), rating 3 or higher for rubbing, and rating 5 for light irradiation. The dyed wool fabric was found to have antimicrobial activity against Staphylococcus aureus. The antioxidant and antimicrobial activity of the Sagassum fusiforme extract can be an effective functional hair colorant. Hair dyeing with the extract formulation at 45℃ for 40 minutes under pH 5 accomplished a K/S value of 8.9. The color fastness of the dyed hair showed rating 3 against light irradiation, which increased to rating 5 with after-mordanting of tannin acid.

Performance Analysis of The KALIMER Breakeven Core Driver Fuel Pin Based on Conceptual Design Parameters

  • Lee Dong Uk;Lee Byoung Oon;Kim Young Gyun;Lee Ki Bog;Jang Jin Wook
    • Nuclear Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.356-368
    • /
    • 2003
  • Material properties such as coolant specific heat, film heat transfer coefficient, cladding thermal conductivity, surface diffusion coefficient of the multi-bubble are improved in MACSIS-Mod1. The axial power and flux profile module was also incorporated with irradiation history. The performance and feasibility of the updated driver fuel pin have been analyzed for nominal parameters based on the conceptual design for the KALIMER breakeven core by MACSIS-MOD1 code. The fuel slug centerline temperature takes the maximum at 700mm from the bottom of the slug in spite of the nearly symmetric axial power distribution. The cladding mid-wall and coolant temperatures take the maximum at the top of the pin. Temperature of the fuel slug surface over the entire irradiation life is much lower than the fuel-clad eutectic reaction temperature. The fission gas release of the driver fuel pin at the end of life is predicted to be $68.61\%$ and plenum pressure is too low to cause cladding yielding. The probability that the fuel pin would fail is estimated to be much less than that allowed in the design criteria. The maximum radial deformation of the fuel pin is $1.93\%$, satisfying the preliminary design criterion ($3\%$) for fuel pin deformation. Therefore the conceptual design parameters of the driver fuel pin for the KALIMER breakeven core are expected to satisfy the preliminary criteria on temperature, fluence limit, deformation limit etc.

Evaluation of thermal shock resistance and thermal shock fracture toughness using $CO_2$ laser for ATJ graphite (ATJ 그라파이트의 $CO_2$ 레이저를 이용한 열충격 강도 및 열충격 파괴인성 평가)

  • Kim, Jae-Hoon;Lee, Young-Sin;Park, No-Seok;Kim, Duk-Hoi;Han, Young-Wook;Seo, Jung;Kim, Jung-Oh
    • Laser Solutions
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • The purpose of this study is to evaluate thermal shock resistance and thermal shock fracture toughness for ATJ graphite. Thermal shock resistance and thermal shock fracture toughness of ATJ graphite are evaluated by using CO$_2$ laser irradiation technique. The laser heat source is irradiated at the center of specimens. Temperature distribution on the specimen surface is measured using the thermocouples of type K and C. SEM and radiographic images are used to observe the cracks which are formed at the thermal shock specimens.

  • PDF

Measurements and Assessments on Shielding Performance of FCTC10 60Co Transport Container

  • Zhuang, Dajie;Zhang, Guoqing;Li, Guoqiang;Wang, Renze
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.310-314
    • /
    • 2016
  • Background: FCTC10 container is designed to transport $^{60}Co$ radioactive sources used in irradiation industry. It belongs to Type B(U) Category III (yellow) package when being loaded with a $^{60}Co$ source of $1.8{\times}10^5$ Ci. Materials and Methods: The container is constituted of shielding container, basket, protective cover and bracket. Shielding ability is provided mainly by stainless steel shells, tungsten alloy and lead among steel shells. Radiation level around the container has been calculated with both Monte Carlo simulations and measurements. Results and Discussion: It is proven that the shielding performance of the container fulfills the requirements in GB11806-2004 (Regulations for the safe transport of radioactive material, China Standard Press). Exposure doses to workers and to critical groups of public were calculated based on hypothetical exposure scene according to transport practice experience. Conclusion: The results show that doses to workers and public are less than the constraint dose considered in design, and the radiation level would be increased less than a factor of 2 under design basis accidents.

SUPERCRITICAL WATER LOOP DESIGN FOR CORROSION AND WATER CHEMISTRY TESTS UNDER IRRADIATION

  • Ruzickova, Mariana;Hajek, Petr;Smida, Stepan;Vsolak, Rudolf;Petr, Jan;Kysela, Jan
    • Nuclear Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.127-132
    • /
    • 2008
  • An experimental loop operating with water at supercritical conditions(25MPa, $600^{\circ}C$ in the test section) is designed for operation in the research reactor LVR-15 in UJV Rez, Czech Republic. The loop should serve as an experimental facility for corrosion tests of materials for in-core as well as out-of-core structures, for testing and optimization of suitable water chemistry for a future HPLWR and for studies of radiolysis of water at supercritical conditions, which remains the domain where very few experimental data are available. At present, final necessary calculations(thermalhydraulic, neutronic, strength) are being performed on the irradiation channel, which is the most challenging part of the loop. The concept of the primary and auxiliary circuits has been completed. The design of the loop shall be finished in the course of the year 2007 to start the construction, out-of-pile testing to verify proper functioning of all systems and as such to be ready for in-pile tests by the end of the HPLWR Phase 2 European project by the end of 2009.

Single Particle Irradiation System to Cell (SPICE) at NIRS

  • Yamaguchi, Hiroshi;Ssto, Yukio;Imaseki, Hitoshi;Yasuda, Nakahiro;Hamano, Tsuyoshi;Furusawa, Yoshiya;Suzuki, Masao;Ishikawa, Takehiro;Mori, Teiji;Matsumoto, Kenichi;Konishi, Teruaki;Yukawa, Masae;Soga, Fuminori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.267-268
    • /
    • 2002
  • Microbeam is a new avenue of radiation research especially in radiation biology and radiation protection. Selective irradiation of an ionizing particle to a targeted cell organelle may disclose such mechanisms as signal transaction among cell organelles and cell-to-cell communication in the processes toward an endpoint observed. Bystander effect, existence of which is clearly evidenced by application of the particle microbeam to biological experiments, suggests potential underestimation in the conventional risk estimation at low particle fluence rates, such as environment of space radiations in ISS (International Space Station). To promote these studies we started the construction of our microbeam facility (named as SPICE) to our HVEE Tandem accelerator (3.4 MeV proton and 5.1 MeV $^4$He$\^$2+/). For our primary goal, "irradiation of single particle to cell organelle within a position resolution of 2 micrometer in a reasonable irradiation time", special features are considered. Usage of a triplet Q magnet for focussing the beam to submicron of size is an outstanding feature compared to facilities of other institutes. Followings are other features: precise position control of cell dish holder, design of the cell dish, data acquisition of microscopic image of a cell organelle (cell nucleus) and data processing, a reliable particle detection, soft and hard wares to integrate all these related data, to control and irradiate exactly determined number of particles to a targeted spot.

  • PDF

Degradation of residual pharmaceuticals in water by UV/H2O2 advanced oxidation process (UV/H2O2 고도산화기술을 이용한 수중 잔류의약물질 제거)

  • Park, Chinyoung;Seo, Sangwon;Cho, Ikhwan;Jun, Yongsung;Ha, Hyunsup;Hwang, Tae-Mun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.469-480
    • /
    • 2019
  • This study was conducted to evaluate the degradation and mineralization of PPCPs (Pharmaceuticals and Personal Care Products) using a CBD(Collimated Beam Device) of UV/H2O2 advanced oxidation process. The decomposition rate of each substance was regarded as the first reaction rate to the ultraviolet irradiation dose. The decomposition rate constants for PPCPs were determined by the concentration of hydrogen peroxide and ultraviolet irradiation intensity. If the decomposition rate constant is large, the PPCPs concentration decreases rapidly. According to the decomposition rate constant, chlortetracycline and sulfamethoxazole are expected to be sufficiently removed by UV irradiation only without the addition of hydrogen peroxide. In the case of carbamazepine, however, very high UV dose was required in the absence of hydrogen peroxide. Other PPCPs required an appropriate concentration of hydrogen peroxide and ultraviolet irradiation intensity. The UV dose required to remove 90% of each PPCPs using the degradation rate constant can be calculated according to the concentration of hydrogen peroxide in each sample. Using this reaction rate, the optimum UV dose and hydrogen peroxide concentration for achieving the target removal rate can be obtained by the target PPCPs and water properties. It can be a necessary data to establish design and operating conditions such as UV lamp type, quantity and hydrogen peroxide concentration depending on the residence time for the most economical operation.

The Modification of Magnetic Properties of Co73Pt27-TiO2 Perpendicular Magnetic Recording Media with Ga+ Ion Irradiation (Ga+ 이온 조사를 통한 Co73Pt27-TiO2 수직자기 기록매체의 자기적 특성 변화)

  • Kim, Sung-Dong;Park, Jin-Joo
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.6
    • /
    • pp.221-225
    • /
    • 2007
  • The effects of $Ga^+$ ion irradiation on the magnetic properties of the $Co_{73}Pt_{27}-TiO_2$ perpendicular magnetic recording media were investigated. As $Ga^+$ ion dose increased from $1\times10^{15}ions/cm^2\;to\;30\times10^{15}ions/cm^2$, the perpendicular magnetic anisotropy was degraded and no longer observed above $20\times10^{15}ions/cm^2$ dose. The deterioration of the perpendicular magnetic anisotropy and ferromagnetic properties can be attributed to the concentration profile change due to Ga+ ion implantation. The magnetic islands of $70\times70nm^2\;and\;100\times100nm^2$ size were successfully fabricated with $Ga^+$ ion irradiation.

A Study on the Design against Metal Fatigue (파로설계에 관한 소고)

  • Lee, Sun-Bok
    • 한국기계연구소 소보
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 1981
  • Fatigue, the birth and growth of cracks in metal parts subjected to repeated loading, has been a problem plaguing engineers since the Industrial Revolution and the advent of rotating or reciprocating machinery. Designing against metal fatigue was studied briefly in several aspects. Examples of fatigue failures were shown. Fatigue was classified by loading: uniaxial Fatigue, multiaxial fatigue, cumulative fatigue da¬mage. Fatigue design criteria were discussed: Infinite-Life Design, Safe-Life Design, Fail-Safe Design, and Damage Tolerant Design. Mitigation of notch effects by design, improvement of fatigue strength of metal parts by residual stress and surface finishing were discussed. Relative fatigue beha¬vior was studied under various environmantal conditions. Especially the effects of corrosion, temperature, fretting, and irradiation were covered.

  • PDF

A Study of Corrosion Resistance Improvement for Cr-Mo Steel in Long Term Service (장기간 사용한 Cr-Mo강의 내식성 향상 방법에 관한 연구)

  • Jin, Yeung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.8-15
    • /
    • 2006
  • It is no wonder that mechanical structures are accompanied by problems related to corrosion after being exposed to long hours of work. Corrosion of mechanical structures has been the most serious problem in the field of industry. The present study employed a laser beam irradiation test to improve the corrosion resistance of degraded Cr-Mo steel, which was used for more than 60,000 hours. To find the optimum irradiation test condition for the corrosion resistance of degraded Cr-Mo steel, hardness and residual stress measurements, micro-structural observation, and the electrochemical potentiokinetic reactivation (EPR) tests were performed with changes in laser beam test conditions including laser beam output, diameter, and velocity. Thus, the present study indicates that the optimum test condition and absorption energy for a laser beam test need to be determined to enhance corrosion resistance of degraded Cr-Mo steel.