• Title/Summary/Keyword: Ir-192

Search Result 157, Processing Time 0.06 seconds

A Study on the Neutron Activation Analysis of Noble Metals in the Ancient Coin (고전(古錢)내 귀금속 원소의 중성자 방사화 분석에 관한 연구)

  • Kwon Soo Chun;Chul Lee;Myung-Zoon Czae;Jong Du Lee;Koo Soon Chung
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.11
    • /
    • pp.961-966
    • /
    • 1993
  • The determination of noble metals such as Ir, Au and Ag in the ancient coins has been studied. For the measurement of the activity of $^{192}Ir,\;^{198}Au\;and\;^{110m}Ag$, radiochemical separations including solvent extraction and ion-exchange chromatography were applied to reduce the interference of high energy ${\gamma}$-ray emitted from various radionuclides with long half-life. As a results, $10^{-11}$ g/g level of Ir could be detected and it was found that the three kinds of the detection limits, i.e., critical, detection, quantitative limit, calculated by the method proposed by Currie, were enhanced. Prior to the re-irradiation with neutron, inactive carrier was added in order to determine the recovery yield of Ir in the radiochemical separation. The average recovery yields of Ir, Au and Ag in the 5 coins were 65.3%, 98.5%, 99.5%, respectively.

  • PDF

Ir-192 Brachytherapy Planning of Brain Tumor (Ir-192 방사성소선원에 의한 뇌종양의 치료계획)

  • Choi Tae Jin;Park Jeong Ho;Kim Ok Bae;Suh Soo Ji
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.277-281
    • /
    • 1988
  • Although widely used in external beam treatment planning, computed tomography scans are infrequent in incranial tumors by implanting of Radioactive isotope. This incranial brachytherapy has only become possible by using CT scans and stereotaxic operation methods. The coincidence of single source and tumor axes in brachytherapy is very important to determine the therapeutic dosages. Eventhough using the CT scan, according to spatial location of tumor tying, the section of tumor will be seen enlargement, cause the tumor will be cut off with slight angle to its axes. Correct analysis of tumor size from source is required for rotated axes in analytical geometry.

  • PDF

Calibration of $^{192}Ir$ HDR Brachytherapy Source in Air and in a Cylindrical Phantom

  • Djarwani S. Soejoko;I, Arief-Riva'
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.23-27
    • /
    • 2002
  • Two $^{192}$ Ir HDR brachytherapy sources were calibrated with a Farmer ionization chamber in air method and in a PMMA cylindrical phantom. The calibration air method used ionization chamber with buildup cap, and 8 variation distances for center-to-center of the source to chamber. In the optimum distance the measured activity, especially for the high activity source, deviation was 0.3% from the activity provided by manufacturer. Calibration with a PMMA cylindrical phantom was less sensitive, and suitable for quick check method with accuracy less than 10%.

  • PDF

Dose assessment of HDR intracavitary brachytherapy using different sources (강내 근접치료에 사용되는 고선량률 Ir-192선원에 따른 치료계획시스템의 선량평가)

  • Yang, Oh-Nam;Lim, Chung-Hwan;Kim, Dae-Yong;Choi, Won-Sik;Shin, Sung-Soo;Ahn, Woo-Sang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.205-206
    • /
    • 2013
  • 자궁경부암 근접치료를 시행했던 환자 10명을 대상으로 동일한 처방에 대한 기하학적 특성이 다른 Ir-192선원을 치료계획시스템을 이용하여 선량평가를 비교 분석 해 보았다.

  • PDF

NEUTRON INDUCED CROSS SECTION DATA FOR IR-191 AND IR-193

  • Lee, Yong-Deok;Lee, Young-Ouk
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.803-808
    • /
    • 2006
  • The neutron induced nuclear cross section data for Ir-191 and Ir-193 were calculated and evaluated from unresolved resonance energy to 20MeV. The energy-dependent optical model potential parameters were determined based on the experimental data and applied up to 20MeV. A spherical optical model, a statistical model in an equilibrium energy region, and a multistep direct and multistep compound model in a pre-equilibrium energy region were used in the calculations. The direct capture model enhanced the fast neutron capture in the pre-equilibrium energy. The theoretically calculated cross sections were compared with the experimental data and the evaluated files. The calculations were found to be in good agreement with the experiment data. The evaluated cross section results were compiled with the ENDF-6 format. The fast energy results will be merged with the resonance parts to create a full evaluation library. The improvement of the neutron-induced cross section data will contribute to an increase in the efficiency of the production of Ir-192 as a radiation source.

Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor (유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정)

  • Shin, Sang-Hun;Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Lee, Bong-Soo;Moon, Joo-Hyun;Kim, Sin;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.