• Title/Summary/Keyword: Ionizing

Search Result 590, Processing Time 0.022 seconds

Characteristics of Glucose-6-phosphate Dehydrogenase from Leuconostoc mesenteroides (Leuconostoc mesenteroides에서 分離한 Glucose-6-phosphate Dehydrogenase의 特性)

  • Byun Si Myung;Yang Do Choi;Moon H. Han
    • Journal of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.248-258
    • /
    • 1979
  • Glucose 6-phosphate dehydrogenase of Leuconostoc mesenteroides which was purifid by an affinity chromatography was studied on the characterization, kinetics and chemical modification. The apparent molecular weight of the enzyme was 112,000 by the gel filtration method of Sephadex G-200 column. The optimum temperature of $NAD^+$-linked reation was 50$^{circ}C$ and the activation energy and the heat of inactivation were 8.36 kcal/mole and -58.2kcal/mole, respectively. The steady state kinetic study showed KG6P, Kemp, and CX KNADP to be 76.9 PM, 7.46${\mu}M$ and 7.14 ${\mu}M$, respectively, and KGGP, KNAD,and aKNm to be 53.7${\mu}M$, 115.2${\mu}M$ and 702.2${\mu}M$ for the $NAD^+$-linked reaction at pH 7.8, optimum pH. The pH dependent kinetic constants suggested that the two ionizing groups whose pKa is 7.2 .and pKb is 9.0-9.6 were involved in the enzyme-substrate interaction. Evidence by photooxidation and carboxymethylation of the enzyme suggested that the imidazole group of histidine with pKa group may participate in the catalytic site.

  • PDF

Conductances of 1-1 Electrolytes in Ethylene Carbonate (탄산에틸렌에서의 1-1 전해질의 전기전도도에 관한 연구)

  • Si-Joong Kim;Joo-Whan Chang;Jin-Ho Kim;Soon-Hee Kang
    • Journal of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.237-242
    • /
    • 1979
  • The equivalent conductances of sodium, potassium, ammonium, tetramethylammonium, triethylammonium, diethylammonium and ethylammonium iodide, and picrate salts of sodium and potassium in ethylene carbonate have been measured at 40.0 $^{\circ}C. The limiting equivalent conductances of the salts have been computed by Fuoss-Onsager-Skinner equation. The limiting ionic equivalent conductances of $Na^+,\;K^+,\;and\;NH^+$ are in order of $Na^+ which is the reverse order of solvation for the ions in any solution, And the order of limiting ionic equivalent conductances for alkylammonium ions is $(C_2H_5)_4N^+<(C_2H_5)_3NH^+<(CH_3)_4N^+<(C_2H_5)_2NH_2^+<(C_2H_5)NH_3^+$ which coincides with the order of mass transfer. From the dissociation constants of the saltss determinde by Fuoss-Kraus method, it is found that ethyene carbonate is a good ionizing solvent for the salts. In addition, Stokes radii and effective fadii of ions have been calculated by Stokes law and Nightingale method, repectively. From the results, it appears tha alkylammonium ions and picrate ion seem to be not solvated, and tha iodide ion is fairly solvated in ethylene carbonate.

  • PDF

Studies of Solvolyses of Di-n-butyl Phosphorochloridate by Extended Grunwald-Winstein Equation (확장된 Grunwald-Winstein 식에 의한 Di-n-butyl Phosphorochloridate의 가용매 분해반응 연구)

  • Kang, Min Sung;Kim, Cheul Ju;Kang, Suk Jin;Koh, Han Joong
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.5
    • /
    • pp.373-378
    • /
    • 2015
  • The solvolysis rate constants of di-n-butyl phosphorochloridate ((CH3CH2CH2CH2O)2POCI, 1) in 28 different solvents are well correlated with the extended Grunwald-Winstein equation, using the NT solvent nucleophilicity scale and YCl solvent ionizing scale, with the sensitivities values of 1.40 and 0.42 for l and m, respectively. These l and m values can be considered to support an SN2 reaction pathway. This interpretation is further supported by the activation parameters, i.e., relatively small positive ΔH (8.0 to 15.9 kcal·mol−1 ) values and large negative ΔS (−25.8 to −53.1 cal·mol−1 ·K−1 ) values, the Kivinen’s n values (0.9~1.7), and the solvent kinetic isotope effect (1.62).

Endonuclease G is Upregulated and Required in Testicular Germ Cell Apoptosis after Exposure to 60 Hz at 200 μT

  • Park, Sungman;Kim, Min-Woo;Kim, Ji-Hoon;Lee, Yena;Kim, Min Soo;Lee, Yong-Jun;Kim, Young-Jin;Kim, Hee-Sung;Kim, Yoon-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.142-150
    • /
    • 2015
  • Several reports supported that continuous exposure to 60 Hz magnetic field (MF) induces testicular germ cell apoptosis in vivo. We recently evaluated duration- and dose-dependent effects of continuous exposure to a 60 Hz MF on the testes in mice. BALB/c male mice were exposed to a 60 Hz MF at $100{\mu}T$ for 24 hours a day for 2, 4, 6, or 8 weeks, and at 2, 20 or $200{\mu}T$ for 24 hours a day for 8 weeks. To induce the apoptosis of testicular germ cell in mice, the minimum dose is $20{\mu}T$ at continuous exposure to a 60 Hz MF for 8 weeks, and the minimum duration is 6 weeks at continuous exposure of $100{\mu}T$. Continuous exposure to a 60 Hz MF might affect duration- and dose-dependent biological processes including apoptotic cell death and spermatogenesis in the male reproductive system of mice. The safety guideline of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) indicates that the permissible maximum magnetic flux density for general public exposure is $200{\mu}T$ at 60 Hz EMF (ICNIRP Guidelines, 2010). In the present study, we aimed to examine the expression of pro- and anti-apoptotic genes regulated by the continuous exposure to 60 Hz at $200{\mu}T$ in Sprague-Dawley rats for 20 weeks. The continuous exposure to 60 Hz at $200{\mu}T$ does not affect the body and testicular weight in rats. However, exposure to 60 Hz MF significantly affects testicular germ cell apoptosis and sperm count. Further, the apoptosis-related gene was scrutinized after exposure to 60 Hz at $200{\mu}T$ for 20 weeks. We found that the message level of endonuclease G (EndoG) was greatly increased following the exposure to 60 Hz at $200{\mu}T$ compared with sham control. These data suggested that 60 Hz magnetic field induced testicular germ cell apoptosis through mitochondrial protein Endo G.

Methodology on the Safety Goal Setting of Reactor Operation based on the Radiogenic Excess Cancer Risk in Korea (한국인의 초과 방사선 암 위험도 평가에 근거한 국내원전의 안전목표치 설정 방법론)

  • Chang, Si-Young;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.131-142
    • /
    • 1999
  • By using the Korean demographic data and the modified relative risk projection model given in the Committee on the Biological Effect of Ionizing Radiation (BEIR) report-V under the U.S. National Academy of Science, the radiogenic excess risk in Korean population has been evaluated. On the basis of this risk, a safety goal for the safe operation of domestic nuclear power plants has been further derived in terms of personal dose. The baseline risk of death due to all causes in Korea and the trivial risk level, which the society considers safe, were estimated to be $5.2{\times}10^{-3}$ and $5.2{\times}10^{-6}$, respectively. The radiogenic excess cancer risk in Korea has been estimated to be $5.2{\times}10^{-3}$ for tie case of acute exposure to 0.1 Gy and $3.7{\times}10^{-3}$ for the case of chronic lifetime exposure to 1.0 mGy/y. On the basis of these risks estimate, the resulting safety goal for one year opeation of a reactor was 0.05 mSv, which is quite identical with the ALARA guideline prescribed by the USNRC in the Appendix I, 10CFR50.

  • PDF

Rapidly and Accurately Processing of Low Melting Block for Shielding of Radiotherapy (방사선(放射線) 치료(治療)의 신속정확(迅速正確)을 위한 저온용융(低溫熔融) 차폐물(遮蔽物)의 제작(製作)과 응용(應用))

  • Chu, S.S.;Lee, D.H.;Park, C.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.14-20
    • /
    • 1979
  • For accurate and easily shielding irregular shaped organ, its minimized penumbra region and a low melting point alloy 'Lead Y' and synchronizing instrument have been developed. The 'Lead Y' is the quaternary eutectic alloy and it is composed of Lead 30.0% Tin 11.5% Bismuth 48 5% Cadmium 10.0% The density of its at $22^{\circ}C$ is $9.8g/cm^3$ and the melting temperature has $40^{\circ}C\;to\;68^{\circ}C$. The thickness of 'Lead Y' for perfect shielding of Co-60 gamma ray and LINAC 10MeV x-ray is 6cm and 7cm respectively. The 'Lead Y' shielding block is casted directly on the styrofoam from which is cut with hot wire of synchronizer device. The special features and advantages of the Lead Y shielding block could be summarized as follows; 1. The shielding block for radiotherapy is rapidly processed only with boiling water and styrofoam. 2. It is not injure one's health and not danger of a fire, because of not generating of any metals vapor and evil smelling. 3. It is very effective to minimize secondary penumbra for the protection of healthy tissue from unnecessary ionizing radiation regardless of the magnification source to skin distance. 4. The HVL of the Lead Y is 1.2cm for Co-60 gamma ray and it's shielding effect is almost same as the pure lead block. 5. The hardness of Lead Y is 1.5 times higher than lead block. 6. It's reavailability is higher than lead block and then one block of Lead Y is reavailable about 30 to 40 times. 7. It is usefull for shielding of x-ray, gamma ray, beta-ray, electron and neutron radiation. 8. The materials for Lead Y are easy to acquire with reasonable price and tractable.

  • PDF

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams (고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교)

  • 박창현;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • A few years ago, a proposal was made to change the dosimetry from the air kerma-based reference dosimetry to the absorbed dose-based reference dosimetry for all radiotherapy beams of ionizing radiation to improve the accuracy of dosimetry. Here, we present a dosimetry study in which the two most widespread absorbed dose­based protocols (IAEA TRS­398 and AAPM TG­51) were compared with an air kerma­based protocol (IAEA TRS-277) by measuring the absorbed dose in the same reference depth. Measurements were performed in three clinical electron beam energies using a PTW 30002 cylindrical chamber, and Markus and Roos plane­parallel chambers. $^{60}$ Co calibration factors were obtained from the KFDA. The absorbed dose differences between the air kerma­based and absorbed dose­based protocols were within 2.0% for all chambers in all beams. The results thus show that the obtained absolute dose values will be not significantly altered by changing from the air kerma­based dosimetry to the absorbed dose­based dosimetry. It was also shown that absorbed dose values between the absorbed dose­based protocols agreed by deviations of less than 0.5% for a cylindrical chamber and less than 0.7% for plane­parallel chambers using cross­calibration factors. Although the use of a cylindrical chamber and plane­parallel chambers resulted in a difference of less than 2% for all situations investigated here, to reduce errors, the plane­parallel chambers are recommended for electron energies in which the use of cylindrical chamber is not permitted in each protocol.

  • PDF

Doses of Electron Beam and X-ray Irradiation for Inhibition of Development and Reproduction in Four Insect Pests (4종 해충의 발육과 생식에 대한 전자빔과 X-ray의 억제선량)

  • Yun, Seung-Hwan;Kim, Minjun;Kim, Hyunah;Lee, Seon-Woo;Yoo, Dae Hyun;Kim, Hyun Kyung;Koo, Hyun-Na;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.391-398
    • /
    • 2014
  • This study investigated inhibitory doses of electron beam and X-ray irradiation by comparing their effects on the development and reproduction of four insect pests (Myzus persicae, Tetranychus urticae, Liriomyza trifolii, and Frankliniella intonsa). When M. persicae nymphs were irradiated with 100 Gy of electron beam and 30 Gy of X-ray beam, offspring production by adults that developed from the treated nymphs was completely inhibited. When M. persicae adults were irradiated with 200 Gy of electron beam and 50 Gy of X-ray beam, emergence of the $F_1$ generation was inhibited. However, these two ionizing radiations did not affect adult longevity. When T. urticae eggs were irradiated with 150 Gy of electron beam and 50 Gy of X-ray beam, egg hatching was completely inhibited. When L. trifolii pupae were irradiated, the emergence rate decreased with increasing doses of X-ray irradiation. After F. intonsa adults were irradiated with 250 Gy of electron beam and 200 Gy of X-ray beam, egg hatching of the $F_1$ generation was completely suppressed.

Control of Botrytis cinerea and Postharvest Quality of Cut Roses by Electron Beam Irradiation (전자빔 조사에 따른 잿빛곰팡이병원균 방제효과와 절화 장미의 수확 후 품질)

  • Kwon, Song;Choi, Gyung Ja;Kim, Ki Sun;Kwon, Hye Jin
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.507-516
    • /
    • 2014
  • The present study was conducted to determine the effect of electron beam irradiation on control of Botrytis cinerea and postharvest quality of cut roses. Electron beam doses of 0.1, 0.2, 0.4, 0.6, 0.8, 1, 2, 10, and 20 kGy were applied with a 10-MeV linear electron beam accelerator (EB Tech, Korea). Electron beams inhibited spore germination and mycelial growth of B. cinerea with increasing irradiation doses. Conidia of B. cinerea were more tolerant to irradiation than were mycelia: the effective irradiation doses for 50% inhibition ($ED_{50}$) of spore germination and mycelial growth were 2.02 kGy and 0.89 kGy, respectively. In addition, electron beam irradiation was more effective in reducing mycelial growth of B. cinerea at $10^{\circ}C$ than at $20^{\circ}C$. Analysis of in vivo antifungal activity revealed that elevated irradiation doses exhibited increased control efficacy for tomato gray mold. Flower longevity and fresh weight of cut roses decreased when the irradiation dose was increased. In addition, flower bud opening tended to be inhibited in a dose-dependent manner. Although 'Decoration', 'Il se Bronze', 'Queen Bee', and 'Revue' roses tolerated and maintained overall postharvest quality up to 0.4 kGy, 'Vivian' did not, demonstrating that the irradiation sensitivity of cut roses varies according to cultivar.