• Title/Summary/Keyword: Ionization Coefficient

Search Result 119, Processing Time 0.024 seconds

Simultaneous determination of aromatic material causing allergic in children's products by Gas Chromatography (어린이 제품 중 가스 크로마토그래피를 이용한 알러지 유발 방향성 물질의 동시분석법)

  • Ko, Kyeong Mok;Rhu, Chan Joo;Kim, Jong Won;Lee, Seok Ki
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.23-30
    • /
    • 2018
  • Twenty-two allergy-induced aromatics in children were analyzed using a gas chromatography flame ionization detector (GC-FID) and gas chromatography mass spectrometer (GC-MSD). Analytes were extracted using an automatic Soxhlet extractor and centrifuged for 10 min in a fast freezing centrifuge, and the supernatant was transferred into a 2 mL vial and injected in split mode. Under the established conditions, the calibration curve showed linearity with a correlation coefficient of 0.996 or more. A wide range of sensitivity of 6.7 to 1,859,839 depending on the device characteristics and detector used was shown. The detection limit of the device was 0.0032 to $0.0335{\mu}g/mL$, and the maximum detection limit was less than $0.1{\mu}g/mL$. The detection limit of the method ranged from 0.0033 to $0.1161{\mu}g/mL$. In addition, the limit of quantification ranged from 0.0100 to $0.5422{\mu}g/mL$, with a level of precision ranging from 0.21 % to 4.89 % and a degree of accuracy ranging from 89 % to 111 %. The analytical method developed in this study was applied to commercial products.

The Study on the Analysis Method of Tetrodotoxin in Puffer Fish (복어 중 테트로도톡신 분석법에 관한 연구)

  • Kang, Young-Woon;Lee, Yoon-Suk;Park, Sung-Kug;Seo, Jung-Heok;Kim, Mee-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.37-41
    • /
    • 2012
  • The current standard for testing tetrodotoxin (TTX) in foodstuffs is the mouse bioassay (MBA) in Korea as in many other countries. However, this test suffers from potential ethical concerns over the use of live animals. In addition, the mouse bioassay does not test for a specific toxin thus a sample resulting in mouse incapacitation would need further confirmatory testing to determine the exact source toxin (e.g., TTX, STX, brevotoxin, etc.). Furthermore, though the time of death is proportional to toxicity in this assay, the dynamic range for this proportional relationship is small thus many samples must be diluted and new mice be injected to yield a result that falls within the quantitative dynamic range. Therefore, in recent years, there have been many efforts in this field to develop alternative assays. High performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) has been emerged as one of the most promising options. A LC-MS-MS method involves solid-phase extraction (SPE) and followed by analysis using an electrospray in the positive ionization mode and multiple reactions monitoring (MRM). To adopt LC-MS-MS method as alternative standard for testing TTX, we performed a validation study for the quantification of TTX in puffer fish. This LC-MS-MS method showed good sensitivity as limits of detection (LOD) of $0.03{\sim}0.08{\mu}g/g$ and limits of quantification (LOQ) of $0.10{\sim}0.25{\mu}g/g$. The linearity ($r^2$) of tetrodotoxin were 0.9986~0.9997, the recovery were 80.9~103.0% and the relative standard deviations (RSD) were 4.3~13.0%. The correlation coefficient between the mouse bioassay and LC/MS/MS method was higher than 0.95.

Study on the Residue Analysis of Organophosphorus and Organochlorine Pesticides with Ion Trap and Quadrupole Mass Spectrometer (Ion Trap Mass Spectrometer와 Quadrupole Mass Spectrometer를 이용한 유기인제 및 유기염소제 농약 분석에 관한 연구)

  • Rhee, Jae-Seong;Park, Hyun-Mee;Er, Yon-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.902-909
    • /
    • 1995
  • Detection limit as well as calibration curves on organophosphorus pesticide(dimethoate, diazinon, parathion-methyl, fenitrothion, malathion) and BHCs were measured for evaluation of utility on qualitative or quantitative analysis of pesticides with ion Trap mass spectrometer and quadrupole mass spectrometer. As ionization source, EI and CI were adopted for qualitative analysis of pesticides by comparison of each fragmentation pattern. At the same time, the utility as trace analysis techniques through scan or selected ion monitoring(SIM) mode was evaluated. With ion trap for all pesticides, detection limit(DL, 1 ${\mu}L$ injection) on scan mode was ranged 0.008∼0.225 ng at signal to noise ratio 3. With quadrupole DL on scan mode was ranged 0.23∼3.1 ng over 0.032∼0.68 ng on SIM mode. The calibration curve with ion trap generated good linearity over 0.99 as correlation coefficient. As clean up procedure, Bio Beads S-X3 was used for the separation of oils from five organophosphorous pesticides in flour extractant showing more than 80% as recovery at most cases. In case of BHCs in jinseng with Florisil column, the recovery of pesticides has been 60% to 90%.

  • PDF

Method Development for the Profiling Analysis of Urine Globotriaosylceramide (Gb3) for the Screening of Fabry Disease by Tandem Mass Spectrometry (ESI-MS/MS를 이용한 소변 중 Globotriaosylceramide(Gb3)의 정량 및 임상 응용; 패브리병(Fabry) 진단)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Kang, Seung-Woo;Kwon, Young-Joo;Jeong, Choon-Sik;Lee, Yong-Soo
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.96-102
    • /
    • 2007
  • Measurement of globotriaosylceramide (Gb3, ceramide trihexoside) in urine has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. A simple, rapid, and highly sensitive analytical method for Gb3 in urine was developed without labor-extensive pre-treatment by electrospray ionization MS/MS (ESI-MS/MS). Only simple 5-fold dilution of urine is necessary for the extraction and isolation of Gb3 in urine. Gb3 in diluted urine was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Eight isoforms of Gb3 were completely resolved from urine matrix. C24:0 Gb3 occupied 50% of total Gb3 as a major component in urine. Linear relationship for Gb3 isoforms was found in the range of 0.005${\sim}$5.0 ${\mu}$g/ml. The limit of detection (S/N=5) was 0.005 ${\mu}$g/ml and limit of quantification was 0.05 ${\mu}$g/ml for C24:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9598 to 0.9975. This method could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

Validation of the LC-MS/MS Method for Ginsenoside Rb1 Analysis in Human Plasma (LC-MS/MS를 이용한 인체 혈장에서 Ginsenoside Rb1의 분석법 검증)

  • Han, Song-Hee;Kim, Yunjeong;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1753-1757
    • /
    • 2012
  • A new liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of ginsenoside Rb1 in human plasma was developed and validated. The separation was performed on a Agilent C18 column ($4.6mm{\times}150mm$, particle size 5 ${\mu}m$) with a gradient elution of 0.1% formic acid in water and 0.1% formic acid in methanol and a flow rate of 0.9 mL/min. The analyte was determined using electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 1131.714${\rightarrow}$365.303). Human plasma samples were extracted with acetone : water (50:50) by the liquid-liquid extraction method. The method was linear over the dynamic range of 10~500 ng/mL with a correlation coefficient of r=0.9995. The intra-and inter-day precision over the concentration range of ginsenoside Rb1 was lower than 5.8% (correlation of variance, CV), and the accuracy was between 96.0~104.6%. This LC-MS/MS assay of ginsenoside Rb1 in human plasma is applicable for quantification in a pharmacokinetic study.

Development and Validation of an Analytical Method for Tridemorph Determination in Tea Samples by Liquid Chromatograph-Electrospray Ionization-Tandem Mass Spectrometry

  • Do, Jung-Ah;Park, Hyejin;Kwon, Ji-Eun;Cho, Yoon-Jae;Chang, Moon-Ik;Oh, Jae-Ho;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.292-298
    • /
    • 2014
  • Tridemorph is a systemic morpholine fungicide for crops. The objective of this study was to develop reliable and sensitive analytical method for determination of tridemorph residues in tea samples for ensuring the food safety. Tridemorph residues in samples were extracted with acetonitrile after hydration, partitioned with saline water, and then purified using an aminopropyl ($NH_2$) SPE cartridge. The purified samples were detected and quantified using LC-ESI-MS/MS. The linear detection limits for tridemorph ranged from 0.02 to $1.0mgL^{-1}$ with a correlation coefficient of 0.9999. The method was validated using tea samples spiked with tridemorph at different concentration levels (0.02 and $0.05{\mu}gmL^{-1}$). The average recovery ranged between 75.0 and 84.7% with relative standard deviations less than 10%. The LOD and LOQ were 0.01 and $0.02mgL^{-1}$, respectively. The developed method was applied successfully to the identification of tridemorph in real tea samples obtained from different sources, and tridemorph was not detected in any of the samples. The results show that the developed analytical method is accurate and suitable for tridemorph determination in tea samples.

Determination of Nitrovin in Fishery Products by Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 니트로빈의 정량분석법 개발 및 검증)

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.118-123
    • /
    • 2018
  • The objective of this study was to develop a sensitive method for the identification and determination of nitrovin in fishery products by using a solid-phase extraction (SPE), as performed with a liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with a mixture of acetonitrile and water, and were then defatted with acetonitrile saturated hexane, after which further clean-up was accomplished with SPE on the hydrophilic-lipophilic balance (HLB) cartridges. The analytes were subsequently ionized in the positive mode of an electrospray ionization (ESI), and where thereby detected in a process of multiple reaction monitoring (MRM). The linearity (expressed as correlation coefficients) of the matrix calibration curves was > 0.985. The limit of the quantification for the nitrovin was measured at 0.001 mg/kg. The accuracy (expressed as average recovery) was noted between 72.1 and 122%. The precision (expressed as coefficient variation) was noted from 2.9 to 16.9%. According to the CODEX CAC/GL-71 guideline accuracy, precision, linearity, and limit of detection were determined in three matrices (which were flatfish, eel and shrimp). The proposed method was suitable for analyzing the associated nitrovin residues. This application and result can also be a factor to contribute to the non-detection drugs management in fishery products.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF