DOI QR코드

DOI QR Code

Simultaneous determination of aromatic material causing allergic in children's products by Gas Chromatography

어린이 제품 중 가스 크로마토그래피를 이용한 알러지 유발 방향성 물질의 동시분석법

  • Ko, Kyeong Mok (Plastic Reliability Center, Korea Conformity Laboratories) ;
  • Rhu, Chan Joo (Plastic Reliability Center, Korea Conformity Laboratories) ;
  • Kim, Jong Won (Plastic Reliability Center, Korea Conformity Laboratories) ;
  • Lee, Seok Ki (Department of Applied Chemistry, Woosuk University)
  • 고경목 (한국건설생활환경시험연구원 플라스틱신뢰성센터) ;
  • 유찬주 (한국건설생활환경시험연구원 플라스틱신뢰성센터) ;
  • 김종원 (한국건설생활환경시험연구원 플라스틱신뢰성센터) ;
  • 이석기 (우석대학교 응용화학과)
  • Received : 2017.07.10
  • Accepted : 2018.01.11
  • Published : 2018.02.25

Abstract

Twenty-two allergy-induced aromatics in children were analyzed using a gas chromatography flame ionization detector (GC-FID) and gas chromatography mass spectrometer (GC-MSD). Analytes were extracted using an automatic Soxhlet extractor and centrifuged for 10 min in a fast freezing centrifuge, and the supernatant was transferred into a 2 mL vial and injected in split mode. Under the established conditions, the calibration curve showed linearity with a correlation coefficient of 0.996 or more. A wide range of sensitivity of 6.7 to 1,859,839 depending on the device characteristics and detector used was shown. The detection limit of the device was 0.0032 to $0.0335{\mu}g/mL$, and the maximum detection limit was less than $0.1{\mu}g/mL$. The detection limit of the method ranged from 0.0033 to $0.1161{\mu}g/mL$. In addition, the limit of quantification ranged from 0.0100 to $0.5422{\mu}g/mL$, with a level of precision ranging from 0.21 % to 4.89 % and a degree of accuracy ranging from 89 % to 111 %. The analytical method developed in this study was applied to commercial products.

어린이 제품 중 22 종의 알러지 유발 방향성 물질들을 기체 크로마토그래피 불꽃 이온화 검출기(GC-FID)와 기체 크로마토그래피 질량 분석기(GC-MSD)를 사용하여 분석하였다. 분석물질들은 자동속슬렛 추출장치를 사용하여 추출하였으며, 고속 냉동 원심분리기에서 10분동안 원심분리 후 상징액을 2 mL vial 옮겨 Split mode로 주입하여 분석하였다. 확립된 조건에서 검정곡선은 0.996 이상의 상관계수를 갖는 직선성을 보였으며, 감도의 경우는 6.7~1,859,839로서 물질별로 기기특성 및 검출기에 따라 상당히 넓은 범위의 감도를 나타내었다. 기기검출한계는 $0.0032{\sim}0.0335{\mu}g/mL$로서 최대 약 $0.1{\mu}g/mL$이하의 기기검출한계를 나타내었고, 방법검출한계는 $0.0033{\sim}0.1161{\mu}g/mL$의 범위를 나타내었다. 또한 정량한계는 $0.0100{\sim}0.5422{\mu}g/mL$의 범위를 보였고, 정밀도는 0.21~4.89 %, 정확도는 89~111%의 범위를 나타내었다. 본 연구에서 개발한 분석법으로 시판품에 실제 적용하였다.

Keywords

References

  1. Korea Ministry of Environment, 'Final Report of the Survey on the third Chemical Substance Distribution', 37, 2007.
  2. Directive 2009/48/EC, 'OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 June 2009 on the safety of toys', Off. J. Eur. Union, 2009.
  3. Directive 2003/15/EC, 'OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 February 2003', Off. J. Eur. Union, 2003.
  4. Regulation (EC) No 1223/2009, 'OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 on cosmetic products', Off. J. Eur. Union, 2009.
  5. SCCNFP, 'An Initial List of Perfumery Materials which must not form part of Fragrance Compounds used in Cosmetic Products', 2000.
  6. SCCNFP, 'The 1st Update of the Inventory of Ingredients Employed in Cosmetic Products, SECTION II: Perfume and Aromatic Raw Materials', 2000.
  7. SCCNFP, 'An Update of the Initial List of Perfumery Materials which must not form part of Fragrance Compounds used in Cosmetic Products', 2003.
  8. EN 71-3, 'Migration of certain elements', 2014.
  9. Korea Ministry of Government Legislation (http://www.law.go.kr/lsInfoP.do?lsiSeq=180383&efYd=20170128#0000).
  10. F. David, C. Devos and P. Sandra, LC.GC Eur., 19(11), 602-616 (2006).
  11. Y. Uda and Y. Maeda, Agric. Biol. Chem., 50(1), 205-208 (1986). https://doi.org/10.1271/bbb1961.50.205
  12. L. H. Wang and H. J. Liu, J. Bioequiv. Availab., 2(3), 72-76 (2010).
  13. B. Desmedt, M. Canfyn, M. Pype, S. Baudewyns, V. Hanot, P. Courselle, J. O. De Beer, V. Rogiers, K. De Paepe, and E. Deconinck, Talanta, 131, 444-451 (2015).
  14. H. Leijs, J. Broekhans, L. Van Pelt and C. Mussinan, J. Agric. Food Chem., 53, 5487-5491 (2005).
  15. IFRA, 'Analytical Procedure Version 3, GC/MS Quantitation of potential fragrance allergens in fragrance compounds', 2007.