Dose rate measurement of Leksell Gamma Knife Perfexion using a 3D printed plastic scintillation dosimeter

  • Lee, Sangmin;Kim, Tae Hoon;Jeong, Jae Young;Son, Jaebum;Kim, Dong Geon;Cho, Gyu-Seok;Choi, Sang Hyoun;Chung, Hyun-Tai;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2334-2338
    • /
    • 2020
  • In recent years, 3D printing technology has received significant research attention. Additionally, 3D printing technology is being applied to study radiation dosimeters of various materials. In this study, a plastic scintillator for 3D printing was developed in a laboratory and used to manufacture a plastic scintillation dosimeter (PSD) with a shape identical to that of the ionization chamber PTW31010. The 16-mm beam of Gamma Knife® Perfexion™ was irradiated to derive the absorbed dose rates of the PSD and PTW31010; they were subsequently compared with the dose rates of the treatment plan. The differences in the dose rates of the Gamma Knife treatment plan and the absorbed dose rates of PTW31010 were within 0.87%. The difference between the dose rates of the Gamma Knife treatment plan and the absorbed dose rates of the PSD were within 4.1%. A linear fit of the absorbed dose rates of four shots involving different dose rates and irradiation angles yielded an adjusted R-square value exceeding 0.9999. A total of 10 repeated measurements were conducted for the same shot to confirm its reproducibility, with a relative error of 0.56%.

전자선의 선량분포에 있어서 Field Shaping의 효과에 관한 연구 (A Study on the Effect of Field Shaping on Dose Distribution of Electron Beams)

  • 강위생;조문준
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.165-172
    • /
    • 1986
  • 전자선 치료시에 납판이나 저융점 합금이 조사면의 형태의 변형을 위하여 사용되고 있다. 콜리메이팅 장치와 마찬가지로 조사면 변형을 위한 물질도 전자선의 출력에 영향을 미친다. 저자들은 폴리스티렌 팬톰에 삽입된 Farmer형 전리함을 이용하여 Clinac-18의 전자선의 변형된 조사면에 대한 출력율을 측정하고 출력율에 영향을 미치는 요인들에 관해 분석했다. 전자선의 출력율은 전자선의 초기 에너지, 콜리메이팅 장치뿐만 아니라 조사면 크기에도 좌우되었다. 변형된 조사면에 대하여 잔자선의 에너지에 관계없이 X-선 콜리메이터와 전자선 어플리케이터의 조합이 고정되면 조사면의 크기 대 출력율은 A/P로 표시된 등가조사면의 크기에 따라 변하지만 조사면의 형태에 대해서는 무시할 수 있었다. 그러나 개조사면에 대한 출력율은 변형조사면의 출력율로부터 예상될 수 없고, 그것들만의 독립적인 관계를 가지고 있었다. 어플리케이터와 콜리메이터의 조합이 고정된 경우에 한해서 판자선의 변형조사면에 대한 출력율은 A/P로서 표시된 등가 조사면 방법에 의하여 구할 수 있다.

  • PDF

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.

Linear Energy Transfer Dependence Correction of Spread-Out Bragg Peak Measured by EBT3 Film for Dynamically Scanned Proton Beams

  • Lee, Moonhee;Ahn, Sunghwan;Cheon, Wonjoong;Han, Youngyih
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.135-144
    • /
    • 2020
  • Purpose: Gafchromic films for proton dosimetry are dependent on linear energy transfers (LETs), resulting in dose underestimation for high LETs. Despite efforts to resolve this problem for single-energy beams, there remains a need to do so for multi-energy beams. Here, a bimolecular reaction model was applied to correct the under-response of spread-out Bragg peaks (SOBPs). Methods: For depth-dose measurements, a Gafchromic EBT3 film was positioned in water perpendicular to the ground. The gantry was rotated at 15° to avoid disturbances in the beam path. A set of films was exposed to a uniformly scanned 112-MeV pristine proton beam with six different dose intensities, ranging from 0.373 to 4.865 Gy, at a 2-cm depth. Another set of films was irradiated with SOBPs with maximum energies of 110, 150, and 190 MeV having modulation widths of 5.39, 4.27, and 5.34 cm, respectively. The correction function was obtained using 150.8-MeV SOBP data. The LET of the SOBP was then analytically calculated. Finally, the model was validated for a uniform cubic dose distribution and compared with multilayered ionization chamber data. Results: The dose error in the plateau region was within 4% when normalized with the maximum dose. The discrepancy of the range was <1 mm for all measured energies. The highest errors occurred at 70 MeV owing to the steep gradient with the narrowest Bragg peak. Conclusions: With bimolecular model-based correction, an EBT3 film can be used to accurately verify the depth dose of scanned proton beams and could potentially be used to evaluate the depth-dose distribution for patient plans.

Development of a Beam Source Modeling Approach to Calculate Head Scatter Factors for a 6 MV Unflattened Photon Beam

  • Park, So-Yeon;Choi, Noorie;Jang, Na Young
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.137-144
    • /
    • 2021
  • Purpose: This study aimed to investigate the accuracy of head scatter factor (Sc) by applying a developed multi-leaf collimator (MLC) scatter source model for an unflattened photon beam. Methods: Sets of Sc values were measured for various jaw-defined square and rectangular fields and MLC-defined square fields for developing dual-source model (DSM) and MLC scatter model. A 6 MV unflattened photon beam has been used. Measurements were performed using a 0.125 cm3 cylindrical ionization chamber and a mini phantom. Then, the parameters of both models have been optimized, and Sc has been calculated. The DSM and MLC scatter models have been verified by comparing the calculated values to the three Sc set measurement values of the jaw-defined field and the two Sc set measurement values of MLC-defined fields used in the existing modeling, respectively. Results: For jaw-defined fields, the calculated Sc using the DSM was consistent with the measured Sc value. This demonstrates that the DSM was properly optimized and modeled for the measured values. For the MLC-defined fields, the accuracy between the calculated and measured Sc values with the addition of the MLC scatter source appeared to be high, but the only use of the DSM resulted in a significantly bigger differences. Conclusions: Both the DSM and MLC models could also be applied to an unflattened beam. When considering scattered radiation from the MLC by adding an MLC scatter source model, it showed a higher degree of agreement with the actual measured Sc value than when using only DSM in the same way as in previous studies.

236U accelerator mass spectrometry with a time-of-flight and energy detection system

  • Li Zheng;Hiroyuki Matsuzaki;Takeyasu Yamagata
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4636-4643
    • /
    • 2022
  • A time-of-flight and energy (TOF-E) detection system for the measurement of 236U accelerator mass spectrometry (AMS) has been developed to improve the 236U/238U sensitivity at Micro Analysis Laboratory, Tandem accelerator (MALT), The University of Tokyo. With observing TOF distribution of 235U, 236U and 238U, this TOF-E detection system has clearly separated 236U from the interference of 235U and 238U when measuring three kinds of uranium standards. In addition, we have developed a novel method combining kernel-based density estimation method and multi-Gaussian fitting method to estimate the 236U/238U sensitivity of the TOF-E detection system. Using this new estimation method, 3.4 × 10-12 of 236U/238U sensitivity and 1.9 ns of time resolution are obtained. 236U/238U sensitivity of TOF-E detection system has improved two orders of magnitude better than that of previous gas ionization chamber. Moreover, unknown species other than uranium isotopes were also observed in the measurement of a surface soil sample, which has demonstrated that TOF-E detection system has a higher sensitivity in particle identification. With its high sensibility in mass determination, this TOF-E detection system could also be used in other heavy isotope AMS.

방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가 (Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.123-130
    • /
    • 2000
  • 전리계의 성능은 방사선 선량측정의 정확도와 정밀도에 직접적으로 영향을 준다. 본 연구에서는 전리계의 성능을 유지하기 위한 정도관리의 항목들을 제시하고 구체적인 성능검사를 시행하고자 한다. 선정된 성능평가 항목들은 적절한 인가전압, 예열 및 고전압 후의 평형시간, 누설에 의한 상쇄 전류, 방사선 측정 전후의 영점이동 (배경전류), 장시간 안정성, 선형성, 외부조건의 영향 등이었다. 전리계에 연결된 자루가 단단한 전리함과 방사선원으로 스트론티움-90이 내장된 검사기가 성능검사용으로 이용되었다. 인가전압의 측정은 전리함의 입력단자에서 직접 측정하였고 평형시간의 측정은 전리계에 전원을 연결한 후와 인가전압을 바꾼 후 검사기에 연결된 전리함의 반응이 안정을 가져오는 시간으로 측정하였다. 누설은 전리계가 안정된 후 방사선을 조사하지 않은 상태에서 전리계의 측정값이 영점에서 이동하는 것으로 나타냈으며 배경전류는 안정된 전리계의 영점을 조정하고 전리계에 연결된 검사기에서 전리함을 10분 조사한 후 영점의 변화로 나타냈다. 장시간의 안정성 3개월에 걸쳐 측정되었으며 이때 검사기의 측정값을 온도-기압에 대한 보정을 한 후 그 값을 비교하였다. 선형성은 전리계에 연결된 전리함을 n번 연속하여 조사하여 그 전체의 측정값과 초기값을 n번 곱한 값을 비교하였다. 외부조건의 영향은 인위적으로 외부온도를 17-34 $^{\circ}C$ 로 변화시켜서 환경변화에 의한 전리계의 영점이동으로 나타냈다. 인가전압의 측정에서 명목상의 인가전압 300, 500V에 대한 측정값은 각각 2.5%와 5.8% 작게 나타났다. 전원을 연결한 후 전리계가 실제로 평형에 도달하는 시간은 20분으로 이는 전리계의 안정성 표시기보다 9분 지연되었으며 인가전압을 바꾼 경우에는 1분 이내에 평형에 도달하였다. 전리계의 누설의 측정에서 영점의 이동은 0.002(스케일)/15분이었고 10분 조사 후 영점의 이동은 발견되지 않았다. 전리계는 3개월 동안 99.4%의 안정성을 유지하였다. 스케일 영역 0.000-9.991 에서 전리계의 선형성에서의 이탈은 0.9% 이었다. 온도 범위 17 - 34 $^{\circ}C$ 에서 전리계의 영점이동은 0.2% 이내였다. 본 연구에서는 임상에서 사용하고 있는 전리계에 대한 성능을 평가하는 항목을 제시하고 이를 전리계의 정도관리에 이용하도록 하였다. 이러한 프로그램의 운용을 통하여 전리계에 의한 오차를 줄임으로써 방사선측정에서의 정확도와 정밀도를 향상시킬 수 있을 것으로 사료된다.

  • PDF

고에너지 광자선에 대한 금속구의 차폐효과 (Protection effect of metal balls against high energy photon beams)

  • 강위생;강석종
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.137-141
    • /
    • 1998
  • 납공 (lead ball)과 쇠공(steel ball)을 고에너지 광자선에 대한 차폐재로 이용하는 것이 가능한가를 평가하고 ,4~10MV 엑스선 차폐를 위한 납공과 쇠공의 물리자료를 구하는 것이 목적이다. 직경이 각각 2.0-2.5mm, 1.5-2.0mm 인 납공 및 쇠공을 폭이 균일한 아크릴 용기에 채워, 두께의 균일성 확인을 위해 MV 엑스선사진을 촬영하였으며, 금속공의 평균 밀도와 4~10MV 엑스선에 대한 선감쇠계수를 측정하였다. 선감쇠계수를 측정할 때 Farmer 이온함을 이용하였으며 산란선의 효과를 최소화하기 위해 70cm 거리에서 조사면크기는 5.5cm$\times$5.5cm로 하였다. 비교하기 위해 납판과 철판에 대해서도 같은 종류의 변수를 구하였다. 금속구를 용기에 채웠을 때 분포는 균일하였으며, 납 -공기 혼합물의 밀도는 6.93g/$cm^3$이었으며, 철-공기 혼합물의 밀도는 4.75g/$cm^3$ 이었다. 납의 밀도에 대한 납-공기 혼합물의 밀도의 비는 0.611, 철에 대한 철-공기 혼합물의 밀도의 비는 0.604이었다. 납-공기 혼합물의 반가층은 4MV, 6MV, 10MV 엑스선 각각에 대하여 1.89cm, 2.07cm, 2.16cm 이었으며 납판 반가층의 약 1.64배였다. 철-공기 혼합물의 반가층은 4MV, 6MV, 10MV 엑스선 각각에 대하여 3.24cm, 3.70cm, 4.15cm 이었으며 철판 반가 층의 약 1.65 배였다. 금속구는 용기속에 고르게 채워질 수 있기 때문에 차폐재료로 쓸 수 있다. 납공과 쇠공이 고르게 채워질 때 밀도는 각각 6.93g/$cm^3$, 4.75g/$cm^3$ 이었으며 각각의 반가층은 납 또는 철의 반가층의 1.65배였다. 밀도와 반가층을 곱한 값은 공이나 판에 대해 같은 값이었다.

  • PDF

전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용 (Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation)

  • 박승진;정웅기;안성자;남택근;나병식
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.233-241
    • /
    • 1994
  • 연구목적 : 전신방사선조사시 인체내에 균등한 선량분포를 얻기 위하여 조직보상체를 제작하고 그에따른 선량 분포를 확인하고자 하였다. 대상 및 방법 : 0.8mm두께의 납판을 이용한 조직보상체와, 1mm 및 5mm 두에의 알루미늄판을 이용한 조직보상체를 두경부와 하지 두 부분에 대하여 각각 제작하였다. 좌우 대향전신조사시 각 신체부위에 따른 선량분포의 측정을 위하여 파라핀으로 성인 크기의 인체 모형을 실제 치료시의 체위와 비슷하게 만들어 사용하였다. 방사선은 10MV X-ray(CLIAC 1800. Varian Co., USA)를, 측정기구는 exposure/exposure rate meter(model 192, Capintec, Inc., USA)with ionization chamber(PR 05)를 이용하였고 SAD 360cm에 파라핀 팬텀의 정중선을 맞추고 기하학적 방사선조사야는 $144{\times}144cm^2$으로하여 전신이 포함되도록 하였으며 head, mouth, mid-neck, sternal notch. mid-mediastinum, xiphoid, umbilicus. pelvis. thigh. knee 및 ankle부위에서 midline absorbed dose를 각각 측정하였다. 흉부의 선량 측정에는 조직등가물질로 제작된 상업용 humanoid 팬텀에서 $1{\times}1{\times}6mm^3$부피의 TLD rod(LiF, Harshaw Co.. Netherland)를 이용하였다. 결과 : Umbilicus를 기준으로 하였을때 조직보상체를 적용하지 않은 경우 흡수선량은 $-11.8\%$에서 $21.1\%$까지의 차이를 보였다. 어깨가 포함되는 sternal notch에서의 선량은 $11.8\%$감소하였다. 조직보상체를 적용한 경우의 흡수선량은 0.8mm 납보상체의 경우 mid-neck에서 $-7.9\%$, 그외 다른 부위는 $+1.3\%$에서 $-5.3\%$가지 였다. 그리고 1mm 및 5mm 알루미늄 보상체를 적용한 경우 ankle부위에서 $5.3\%$. 그외 다른 부위는 $-2.6\%$에서 $2.6\%$가지의 흡수선량 차이를 보였다. 결론 : 납과 알루미늄으로 제작한 전신방사선조사용 조직보상체는 선량기준점인 umbilicus선량에 비교하였을 때 두경부와 하지에 있어서 비교적 만족할만한 보상효과를 나타내었다. 어깨가 있는 상흉부에서는 선량이 $11.8\%$ 정도 감소하므로 환자의 lateral thickness 차이에 따라 선량기준점을 sternal notch로 선택하거나 boost irradiation이 고려되어야함을 알 수 있었다.

  • PDF

유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인 (Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation)

  • 박병문;배용기;강민영;방동완;김연래;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.277-282
    • /
    • 2010
  • 본 연구의 목적은 유방암 환자의 절선조사 시 종속조사면 병합(FIF) 치료방법을 2차원 이온전리함을 이용하여 불균등한 선량분포를 확인하고자하였다. 실험을 위해 2차원 이온전리함 배열(MatriXX, Wellhofer Dosimetrie, Germany)와 치료계획장치(Eclipse, ver 6.5, Varian, Palo Alto, USA)가 사용되었다. 불균등한 선량분포 확인을 위해 FIF 방법으로 치료계획 한 20명의 환자를 선택하여 각각 90 cGy를 처방하여 하이브리드계획을 수행하였으며, 측정값과 비교를 위해 동일한 기하학적 조건에서 MatriXX를 이용해 측정하였다. 정량적인 분석을 위해 상용화된 분석 소프트웨어(OmniPro IMRT, ver, 1.4, Wellhofer, Dosimetrie, Germany)를 이용하여 분석하였다. 실험 결과로 기준점에 선량처방 시 계산값과 측정값이 평균 1.6% 차이를 보였고, 선형프로파일(Line-Profile)을 통해 분석한 결과 종단면에서는 1.3-5.5%(평균 : 2.4%), 횡단면에서는 0.9-3.9%(평균 : 2.5%)로 변동을 보였다. 감마인덱스 히스토그람(기준 : 3 mm, 3%)로 분석한 결과 90.23-99.69%(평균 : 95.11%, 표준편차 : 2.81) 범위를 나타냈다(유효범위 ; $\gamma$-index $\geq$ 1). 본 실험에서는 MatriXX 이용하여 측정한 결과 치료계획 선량과 측정값이 오차범위 이내로 일치하였으며, 향후 다양한 종양치료에 있어 FIF방법의 활용도를 높이는 연구가 필요하다고 생각한다.