• 제목/요약/키워드: Ion irradiation

검색결과 453건 처리시간 0.023초

제올라이트와 감마선을 이용한 축산 폐수 처리 (Livestock Wastewater Treatment by Zeolite Ion Exchange and Gamma-ray Irradiation)

  • 이상률;김탁현;이면주
    • 방사선산업학회지
    • /
    • 제2권1호
    • /
    • pp.9-14
    • /
    • 2008
  • Livestock wastewater containing high concentrations of organic matters and ammonia-nitrogen has been known as one of the recalcitrant wastewater. It is difficult to treat by conventional wastewater treatment techniques. This study was carried out to evaluate the feasibility of zeolite ion exchange and gamma-ray irradiation treatment of livestock wastewater. The removal efficiencies of $SCOD_{Cr}$ and $NH_3-N$ were significantly enhanced by gamma-ray irradiation after zeolite ion exchange as a pre-treatment. However, the effects of zeolite particle size on the $SCOD_{Cr}$ and $NH_3-N$ removal efficiencies were insignificant. These results indicate that the combined process of zeolite ion exchange and gamma-ray irradiation has potential for the treatment of livestock wastewater.

이온빔 조사 각도에 따른 액정 배향 특성 연구 (Investigation of LC Alignment characteristic by Controlling Ion-beam Irradiation angles)

  • 박홍규;오병윤;김영환;김병용;한진우;전지연;한정민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 및 기술 세미나 논문집 디스플레이 광소자
    • /
    • pp.43-43
    • /
    • 2008
  • Recently, it is widely studied to liquid crystal (LC) alignment using ion-beam exposure. Because conventional rubbing method has some problems such as defects from dust and electrostatic charges and rubbing scratch during rubbing process. Moreover rubbing method needs cleaning process to remove these defects. Therefore rubbing-free techniques like ion-beam method are strongly required. We studied LC alignment by controlling ion-beam irradiation angles and electro-optical (EO) characteristics of twisted nematic LC on the polyimide surface. In this experiment, a good uniform alignment of the nematic liquid crystal (NLC) with the ion-beam exposure on the polyimide (PI) surface was observed. We also achieved low pretilt angle as function of ion-beam irradiation angles. X-ray photoelectron spectroscopic (XPS) analysis provided chemical evidence for LC alignment by controlling ion-beam irradiation angles. In addition, it can be achieved the good EO properties of the ion-beam-aligned twisted nematic liquid crystal display (TN-LCD) on PI surface. Some other experiments results and discussion will be included in the presentation.

  • PDF

고체 표면 식각 및 평탄화를 위한 가스 클러스터 이온원 개발 (Gas Cluster ion Source for Etching and Smoothing of Solid Surfaces)

  • 송재훈;최덕균;최원국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.232-235
    • /
    • 2002
  • An 150 kV gas cluster ion accelerator was fabricated and assessed. The change of surface morphology and surface roughness were examined by an atom force microscope (AFM) after irradiation of $CO_2$ gas clusters on Si (100) surfaces at the acceleration voltages of 50 kV. The density of hillocks induced by cluster ion impact was gradually increased with the dosage up to 5$\times$10$^{11}$ ions/$\textrm{cm}^2$. At the boundary of the ion dosage of 10$^{12}$ ions/$\textrm{cm}^2$, the density of the induced hillocks was decreased and RMS (root mean square) surface roughness was not deteriorated further. At the dosage of 5x10$^{13}$ ions/$\textrm{cm}^2$, the induced hillocks completely disappeared and the surface became very flat. In addition, the irradiated region was sputtered. $CO_2$ cluster ions are irradiated at the acceleration voltage of 25 kV to remove hillocks on indium tin oxide (ITO) surface and thus to attain highly smooth surfaces. $CO_2$ monomer ions are also bombarded on the ITO surface at the same acceleration voltage to compare sputtering phenomena. From the AFM results, the irradiation of monomer ions make the hillocks sharper and the surfaces rougher On the other hand, the irradiation of $CO_2$ cluster ions reduces the hight of hillocks and planarize the ITO surfaces. From the experiment of isolated cluster ion impact on the Si surfaces, the induced hillocks m high had the surfaces embossed at the lower ion dosages. The surface roughness was slightly increased with the hillock density and the ion dosage. At higher than a critical ion dosage, the induced hillocks were sputtered and the sputtered particles migrated in order to fill valleys among the hillocks. After prolonged irradiation of cluster ions, the irradiated region was very flat and etched.

  • PDF

Deuterium ion irradiation impact on the current-carrying capacity of DI-BSCCO superconducting tape

  • Rajput, M.;Swami, H.L.;Kumar, R.;Bano, A.;Vala, S.;Abhangi, M.;Prasad, Upendra;Kumar, Rajesh;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2586-2591
    • /
    • 2022
  • In the present work, we have irradiated the DI-BSCCO superconducting tapes with the 100 keV deuterium ions to investigate the effect of ion irradiation on their critical current (Ic). The damage simulations are carried out using the binary collision approximation method to get the spatial distribution and depth profile of the damage events in the high temperature superconducting (HTS) tape. The point defects are formed near the surface of the HTS tape. These point defects change the vortex profile in the superconducting tape. Due to the long-range interaction of vortices with each other, the Ic of the tape degrades at the 77 K and self magnetic field. The radiation dose of 2.90 MGy degrades the 44% critical current of the tape. The results of the displacement per atom (dpa) and dose deposited by the deuterium ions are used to fit an empirical relation for predicting the degradation of the Ic of the tape. We include the dpa, dose and columnar defect terms produced by the incident particles in the empirical relation. The fitted empirical relation predicts that light ion irradiation degrades the Ic in the DI-BSCCO tape at the self field. This empirical relation can also be used in neutron irradiation to predict the lifetime of the DI-BSCCO tape. The change in the Ic of the DI-BSCCO tape due to deuterium irradiation is compared with the other second-generation HTS tape irradiated with energetic radiation.

$MgB_2$ 초전도 박막의 경이온 조사에 의한 효과 (Effects of Light-ion Irradiation on Superconducting $MgB_2$ thin Films)

  • 이남훈;성원경;;김소연;박성하;강원남
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.8-12
    • /
    • 2009
  • We investigated the effects of the irradiation of light-ions on the superconducting $MgB_2$ thin films fabricated by using HPCVD. Deuterium and helium ions were irradiated on $MgB_2$ thin films by various doses, from $1{\times}10^{10}cm^{-2}\;to\;8{\times}10^{15}cm^{-2}$. During these experiments some reasonable results and unpredictable results have been obtained. The reasonable results are that the peak of the reduced maximum pinning force shifts by increasing the pinning sites in $MgB_2$ films and the slightly change of critical current density of films. We obtained some unusual results, which are the increasing of the transition temperature and the change of residual resistance ratio. Among the data of deuterium and helium ion irradiation experiments, the results of helium ion irradiation have most notable points so we will discuss mainly about helium irradiation experiments.

  • PDF

Electro-optical Characteristics of the One-side Rubbing TN-LCD on Polyimide Surface with Ion-beam Irradiation

  • Kim, Young-Hwan;Lee, Kang-Min;Kim, Byoung-Yong;Oh, Byeong-Yun;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.198-201
    • /
    • 2008
  • The electro-optical (EO) characteristics of the one-side rubbing twisted nematic (TN) - liquid crystal display (LCD) on the polyimide (PI) surface with one-side ion beam (IB) irradiation were successfully studied. The good LC alignment for the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation was observed. The suitable transmittance-voltage curves for the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation were measured. Also, the good response time characteristics of the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation were measured. The fast response time can be achieved for the one-side rubbing TN-LCD on the PI surface with one-side IB irradiation.

Multiscale simulations for estimating mechanical properties of ion irradiated 308 based on microstructural features

  • Dong-Hyeon Kwak ;Jae Min Sim;Yoon-Suk Chang ;Byeong Seo Kong ;Changheui Jang
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2823-2834
    • /
    • 2023
  • Austenitic stainless steel welds (ASSWs) of nuclear components undergo aging-related degradations caused by high temperature and neutron radiation. Since irradiation leads to the change of material characteristics, relevant quantification is important for long-term operation, but limitations exist. Although ion irradiation is utilized to emulate neutron irradiation, its penetration depth is too shallow to measure bulk properties. In this study, a systematic approach was suggested to estimate mechanical properties of ion irradiated 308 ASSW. First of all, weld specimens were irradiated by 2 MeV proton to 1 and 10 dpa. Microstructure evolutions due to irradiation in δ-ferrite and austenite phases were characterized and micropillar compression tests were performed. In succession, dislocation density based stress-strain (S-S) relationships and quantification models of irradiation defects were adopted to define phases in finite element analyses. Resultant microscopic S-S curves were compared to verify material parameters. Finally, macroscopic behaviors were calculated by multiscale simulations using real microstructure based representative volume element (RVE). Validity of the approach was verified for the unirradiated specimens such that the estimated S-S curves and 0.2% offset yield strengths (YSs) which was 363.14 MPa were in 10% agreement with test. For irradiated specimens, the estimated YS were 917.41 MPa in 9% agreement.

Ga+ 이온 조사를 통한 Co73Pt27-TiO2 수직자기 기록매체의 자기적 특성 변화 (The Modification of Magnetic Properties of Co73Pt27-TiO2 Perpendicular Magnetic Recording Media with Ga+ Ion Irradiation)

  • 김성동;박진주
    • 한국자기학회지
    • /
    • 제17권6호
    • /
    • pp.221-225
    • /
    • 2007
  • [ $Co_{73}Pt_{27}-TiO_2$ ] 수직자기 기록매체에 대해 집속이온빔(FIB)을 이용한 $Ga^+$ 이온 조사에 따른 자기적 특성의 변화를 조사하였다. $Ga^+$ 이온 도즈량을 $1\times10^{15}ions/cm^2$에서 $30\times10^{15}ions/cm^2$까지 증가시켰을 때 도즈량 $20\times10^{15}ions/cm^2$ 이상에서 수직자기이방성 및 강자성 특성이 사라지는 것이 관찰되었으며, 이는 스퍼터링 효과에 따른 수직자기 기록층의 두께 감소보다는 $Ga^+$ 이온 주입에 따른 수직자기 기록매체내의 조성 분포의 변화에 따른 것으로 보인다. $Ga^+$ 이온 조사법을 이용하며 $70\times70nm^2,\;100\times100nm^2$ 크기의 자기구조체 패턴을 형성하였다.

Research Activities at National Institute of Radiological Sciences in Development of Radiological Apparatus

  • Endo, Masahiro
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.3-5
    • /
    • 2002
  • This paper describes research activities at National Institute of Radiological Sciences (NIRS), Japan in development of radiological apparatus, which cover 4-dimensinal (4D) CT, next-generation PET and several progresses in heavy-ion irradiation system at HIMAC (Heavy Ion Medical Accelerator in Chiba).

  • PDF

이온빔 조사에 따른 Gd-doped Ceria의 특성 변화 (Ion-Beam Induced Changes in the Characteristics of Gd Doped Ceria)

  • 김태형;류부형;이인자
    • 공업화학
    • /
    • 제21권4호
    • /
    • pp.401-404
    • /
    • 2010
  • GDC (Gadolinium doped ceria) 펠렛에 120 keV 및 5 MeV 에너지의 양성자 또는 제논 이온을 주입하였으며, 그 영향을 UV-vis 분광계, SEM 및 XRD를 이용하여 측정하였다. GDC 펠렛은 cubic fluorite 구조를 갖는 조밀한 소결체였으며, 갈색이었던 펠렛이 이온빔을 조사한 후 옅은 검은색을 띠기 시작하였으며, fluence가 증가함에 따라 색도 짙어졌다. XRD 패턴은 이온의 에너지 및 X선의 투과 깊이와 밀접한 관계가 있었으며, 120 keV의 양성자 빔을 조사한 표면 바로 아래층은 이온의 주입으로 결정 구조는 유지한 채 격자 상수가 증가하였다는 것을 관찰하였다.