Solid Phase Extraction of Phospholipids from Brazil Nut (Bertholletia excelsa) and Their Characterization by Mass Spectrometry Analysis

  • Lima, Bruna R. De;Silva, Felipe M.A. Da;Koolen, Hector H.F.;Almeida, Richardson A. De;Souza, Afonso D.L. De
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.115-119
    • /
    • 2014
  • The Brazil nut (Bertholletia excelsa - Lecythidaceae) is considered a product with high economic value, being a food widely appreciated for its nutritional qualities. Although previous studies have reported the biochemical composition of Brazil nut oil, the knowledge regarding the phospholipid composition exhibits a disagreement: the composition of fatty acids present in the structures of phospholipids is reported as being different from the composition of the free fatty acids present in the oil. In this work, solid phase extraction (SPE) was employed to provide a fast extraction of the phospholipids from Brazil nuts, in order to compare the phospholipid profile of the in nature nuts and their fatty acids precursor present in the oil. The major phospholipids were characterized by mass spectrometry approach. Their fragmentation pattern through direct infusion electrospray ionization ion-trap tandem mass spectrometry ($ESI-IT-MS^2$) proved to be useful to unequivocal characterization of these substances. High resolution (HR) experiments through ESI using a quadruple time of flight mass spectrometry (QTOF) system were performed to reinforce the identifications.

A Selectivity Character for the Phase Transfer Reactions of Alcohols by Tetra-n-Butyl Ammonium Chloride (Tetra-n-Butyl Ammonium Chloride에 의한 알코올류의 상전이 반응에 대한 선택 특이성)

  • Jee, Jong-Gi;Cboi, Won-Bok;Lee, Kwang-Pill
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.33-40
    • /
    • 1995
  • Only trace amounts of hydroxide ion can be extracted from aqueous phase into organic phase by Tetra-n-Butyl Ammonium Chloride(TBAC). Addition of small amounts of primary alcohols, particularly certain dials, dramatically changes the behavior of Phase Transfer Catalysis systems, and surprising amounts of base can be found in the organic phase. Quantitative measurements were carried out for the extraction amounts of primary alkoxides, secondary alkoxides, and diol anions into organic phase. On the other hand, the selectivity constants for extraction of primary alcohols and benzylalcohol could be separated to the equilibrium constants of the ion pairs such as $Q^+RO^-$ and $Q^+Cl^-$ in the aqueous and organic phases and this distribution coefficients between phases on anions respectively. In a word, the colligated property for the selectivity of $Q^+RO^-$ in which $Q^+$ is quaternary cation and $RO^-$ alkoxide ion could be discussed in more detail by using of the corresponding free energies to the various constants mentioned.

  • PDF

Removing Lipemia in Serum/Plasma Samples: A Multicenter Study

  • Castro-Castro, Maria-Jose;Candas-Estebanez, Beatriz;Esteban-Salan, Margarita;Calmarza, Pilar;Arrobas-Velilla, Teresa;Romero-Roman, Carlos;Pocovi-Mieras, Miguel;Aguilar-Doreste, Jose-Angel;Commission on Lipoprotein and Vascular Diseases, Sociedad Espanola de Quimica Clinica
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.518-523
    • /
    • 2018
  • Background: Lipemia, a significant source of analytical errors in clinical laboratory settings, should be removed prior to measuring biochemical parameters. We investigated whether lipemia in serum/plasma samples can be removed using a method that is easier and more practicable than ultracentrifugation, the current reference method. Methods: Seven hospital laboratories in Spain participated in this study. We first compared the effectiveness of ultracentrifugation ($108,200{\times}g$) and high-speed centrifugation ($10,000{\times}g$ for 15 minutes) in removing lipemia. Second, we compared high-speed centrifugation with two liquid-liquid extraction methods-LipoClear (StatSpin, Norwood, USA), and 1,1,2-trichlorotrifluoroethane (Merck, Darmstadt, Germany). We assessed 14 biochemical parameters: serum/plasma concentrations of sodium ion, potassium ion, chloride ion, glucose, total protein, albumin, creatinine, urea, alkaline phosphatase, gamma-glutamyl transferase, alanine aminotransferase, aspartate-aminotransferase, calcium, and bilirubin. We analyzed whether the differences between lipemia removal methods exceeded the limit for clinically significant interference (LCSI). Results: When ultracentrifugation and high-speed centrifugation were compared, no parameter had a difference that exceeded the LCSI. When high-speed centrifugation was compared with the two liquid-liquid extraction methods, we found differences exceeding the LCSI in protein, calcium, and aspartate aminotransferase in the comparison with 1,1,2-trichlorotrifluoroethane, and in protein, albumin, and calcium in the comparison with LipoClear. Differences in other parameters did not exceed the LCSI. Conclusions: High-speed centrifugation ($10,000{\times}g$ for 15 minutes) can be used instead of ultracentrifugation to remove lipemia in serum/plasma samples. LipoClear and 1,1,2-trichlorotrifluoroethane are unsuitable as they interfere with the measurement of certain parameters.

Fabrication of K-PHI Zeolite Coated Alumina Hollow Fiber Membrane and Study on Removal Characteristics of Metal Ions in Lignin Wastewater

  • Zhuang, XueLong;Shin, Min Chang;Jeong, Byeong Jun;Lee, Seung Hwan;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.174-179
    • /
    • 2021
  • Recently, hybrid coal research is underway to upgrade low-grade coal. The hybrid coal is made by mixing low-grade coal with bioliquids such as molasses, sugar cane, and lignin. In the case of lignin used here, a large amount of lignin is included in the wastewater of the papermaking process, and thus, research on hybrid coal production using the same is attracting attention. However, since a large amount of metal ions are contained in the lignin wastewater from the papermaking process, substances that corrode the generator are generated during combustion, and the amount of fly ash is increased. To solve this problem, it is essential to remove metal ions in the lignin wastewater. In this study, metal ions were removed by ion exchange with a alumina hollow fiber membrane coated with K-Phillipsite (K-PHI) zeolite. The alumina hollow fiber membrane used as the support was prepared by the nonsolvent induced phase separation (NIPS) method, and K-PHI seeds were prepared by hydrothermal synthesis. The prepared K-PHI seed was seeded on the surface of the support and coated by secondary growth hydrothermal synthesis. The characteristic of prepared coating membrane was analyzed by Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), Energy Dispersive Spectroscopy (EDX), and the concentration of metal ions before and after ion exchange was measured by Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES). The extraction amount of K+ is 86 mg/kg, and the extraction amount of Na+ is 54.9 mg/kg. Therefore, K-PHI zeolite membrane has the potential to remove potassium and sodium ions from the solution and can be used in acidic lignin wastewater.

Comparison of methods for proanthocyanidin extraction from pine (Pinus densiflora) needles and biological activities of the extracts

  • Kim, Nam-Young;Jang, Min-Kyung;Lee, Dong-Geun;Yu, Ki-Hwan;Jang, Hye-Ji;Kim, Mi-Hyang;Kim, Sung-Gu;Yoo, Byung-Hong;Lee, Sang-Hyeon
    • Nutrition Research and Practice
    • /
    • v.4 no.1
    • /
    • pp.16-22
    • /
    • 2010
  • Flavonoids are known to be effective scavengers of free radicals. In particular, proanthocyanidins are flavonoids that possess cardiovascular protection, antioxidative activities, and immunomodulatory activities. Here, we evaluated proanthocyanidin contents in the total polyphenolic compounds of pine needle extracts prepared by hot water, ethanol, hexane, hot water-hexane (HWH), and hot water-ethanol (HWE). Analysis of each extract indicated that the ethanol extract contained the highest proanthocyanidin concentration. The HWH and hexane extracts also contained relatively high concentrations of proanthocyanidin. On the other hand, proanthocyanidin content analyses out of the total polyphenolic compounds indicated that the HWH extract contained the highest content. These results suggest that HWH extraction is a suitable method to obtain an extract with a high level of pure proanthocyanidins and a relatively high yield. The HWH extract possessed superior activity in diverse antioxidative analyses such as 2,2-diphenyl-1-picrylhydrazyl (DPPH), ferrous ion chelating (FIC), and ferric-ion reducing power (FRAP) assays. In addition, upon assessing the effects of the pine needle extracts on macrophages (Raw 264.7 cell), the HWH extract exhibited the highest activity. In this study, we discerned an efficient extraction method to achieve relatively pure proanthocyanidins from pine needles and evaluated the biological functions of the resulting extract, which could potentially be used for its efficacious components in functional food products.

Simultaneous analysis of sulfonamides in beef and pork by high performance liquid chromatography and electrospray ionization mass spectrometry (HPLC와 LC/MS에 의한 식육내 잔류 설파제의 동시 분석법)

  • 정봉수;박준조;금모래;김인경;박병옥;한정희
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.1
    • /
    • pp.17-29
    • /
    • 2004
  • A multiresidual analysis was performed to determine 12 sulfonamides(sulfacetamide, sulfadiazine, sulfisomidine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine, sulfamonomethoxine, sulfisoxazole, sulfamethoxazole, sulfaquinoxaline, and sulfadimethoxine) in beef and pork simultaneously. The multiresidual analysis for the sulfonamides currently used was able to analyze 5 kinds of sulfonamides at the same time. The method of this 12 sulfonamides multiresidual analysis in this study was matrix solid-phase dispersion(MSPD) by high performance liquid chromatography (HPLC) and liquid chromatography mass spectrometry (LC/MS). The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM: Ethylacetate(3:1), DCM:EA(9:1). Also, samples (84 beef and 205 pork samples) which were positive by EEC-4 plate test from 2001 to 2003 were tested to investigate the kinds of sulfonamides using HPLC. The results from the study were as follows; 1. The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM:Ethylacetate(3:1), DCM:EA(9:1). The method of extraction solvent with DCM:ethyl acetate(9:1) was the most excellent(87.7∼99.3%) in separation and reappearance. 2. In the LC/MS analysis. of sulfonamides, signal to noise ratio was showed relatively high in the positive mode and special ion in the quality analysis was determined via [M+H]$\^$+/ and m/z 156. A spectrum of sulfonamides was showed from all 12 sulfonamides. 3. The samples positive by the EEC-4 plate, a screening test method, were categorized by sulfonamides through Charm II and confirmed the kinds of sulfonamides through HPLC. 1) Among 84 beef samples positive by EEC-4 plate, 20 samples were positive by Charm II and identified as 7 sulfamethazine, 9 sulfadimethoxine, 1 sulfamonomethoxine and 3 unknown status. 2) Among 205 pork samples positive by EEC-4 plate, 42 samples were positive by Charm II and identified as 19 sulfamethazine, 1 sulfadimethoxine, 4 sulfamonomethoxine and 5 unknown status.

Optimization of Extraction and Purification of Phytic Acid from Defatted Rice Bran (탈지미강으로부터 Phytic Acid의 추출과 정제의 최적화)

  • Choi, Moon Sil;Han, Bok Kyung;Choi, Hyuk Joon;Park, Young-Seo
    • Food Engineering Progress
    • /
    • v.15 no.3
    • /
    • pp.276-281
    • /
    • 2011
  • The optimum condition for the extraction and purification processes of phytic acid from defatted rice bran was examined. The phytic acid was efficiently extracted when the defatted rice bran was treated with 10 volumes of 0.5% HCl for 1 hr. For the neutralization of acid-treated extract, 0.5% NaOH was the most acceptable. To purify phytic acid, Diaion HP20 resin was used to remove impurities from the extract. The flow-through was then loaded onto ion exchange columns packed with various resins and among them, Amberlite IRA-416 resin showed highest recovery yield. When the phytic acid was absorbed onto Amberlite IRA-416 resin and then eluted with 0.5% NaOH, 89% of applied phytic acid was eluted. Most proteins were removed from the purified phytic acid and total protein content of the phytic acid was 0.14%(w/w).

A Study on the Characteristics of Calcium Ion Separation by Adding Acidic/Basic Reagents (산/염기성 물질 주입에 따른 칼슘이온 분리 특성 연구)

  • Lee, Ye Hwan;Kim, Jeongeun;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.103-107
    • /
    • 2020
  • The purpose of this study is to resource calcium ions contained in most industrial by-products, and confirm the characteristics of calcium ions by extraction and separation conditions. Calcium oxide was used as a calcium extraction source, and hydrochloric acid as an extraction solvent, and the extraction amount according to the concentration of the extraction solvent and the pH dependent characteristics of the extract were analyzed. As the extractant concentration increased, the extracted amount increased while the pH for the extraction was kept constant. In order to separate extracted calcium ions, an acid-basic solution was injected and the formation of precipitates and also the form of precipitates were analyzed. When the sulfuric acid and sodium hydroxide solution of acid and basic substances were injected into the calcium extract, precipitates were formed and separated into CaSO4 and Ca(OH)2 forms.

AN EXPERIMENTAL STUDY OF THE EFFECT OF THE UNILATERAL TOOTH LOSS ON THE TEMPOROMANDIBULAR JOINT (편측치아결손(片側齒牙缺損)이 악관절(顎關節)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lim, Yong-Joon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.17 no.1
    • /
    • pp.35-46
    • /
    • 1979
  • A number of experimental studies have been carried out in order to clarify the question as to how temporomandibular joint adapt to the changes of mandibular movement and occlusal equilibration. Recently, the studies on the interrelations between anatomical structure of temporomandibular joint and the state of occlusion have been actively performed in dentistry particularly in prosthodontic field. Author performed extraction of unilateral mandibular molars in 30 mature male rats, and observed histological changes of temporomandibular joint through the light microscope. Following results were obtained. 1. The loss of unilateral teeth gave rise to the changes in the location of condylar head, that is, interior displacement of condylar head in the extraction side and upper displacement in the non-extraction side. 2. Articular disk was compressed by the interior surface of condylar head, resulting in its extension below the condylar neck in the extraction side, and the histological arrangement of the compressed area showed irregular feature. 3. The extension of articular disk below the condylar neck was accompanied with the contraction of muscle fibers which were originated from the articular disk. 4. The cartilage layer of articular fossa to the exterior of the extraction side showed hypertropy. 5. Early in the experiment, the inernal extremity of condylar head of extract ion side showed bone resorption, and cartilage layer of condylar head showed hypertropy. At 12 weeks after experiment, the condylar surface showed flattened, and the cartilage layer of condylar head was replaced by the compact bone. 6. The articular disk showed the formation of pannus in the extraction side as well as in the non-extraction side. 7. The occlusal disturbance due to unilateral missing teeth has brought about the non-inflammatory retrogressive change and osteoarthrotic change late in the experiment.

  • PDF

Experimental Results of New Ion Source for Performance Test

  • Kim, Tae-Seong;Jeong, Seung-Ho;Jang, Du-Hui;Lee, Gwang-Won;In, Sang-Yeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF