• 제목/요약/키워드: Ion concentration

검색결과 2,962건 처리시간 0.03초

급격한 온도 변화에 따른 리튬 이온 배터리의 전해질 내 염 농도 분포 특성 (Characteristics of Salt Concentration in Electrolyte of Lithium Ion Battery According to Sudden Temperature Change)

  • 장경민;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제16권1호
    • /
    • pp.11-15
    • /
    • 2017
  • Lithium-ion batteries are widely used, from lightweight to energy-intensive, from small devices to large ESSs. However, it is sensitive to the surrounding environment and there is a change in performance depending on the temperature change. In this study, the temperature dependence of the charge / discharge characteristics of the battery is shown through simulation and the distribution of the salt concentration in the electrolyte is observed when the sudden temperature change is applied.

  • PDF

이온交換樹脂膜을 利用한 電氣透析의 檢討 (Study on the Electrodyalisis Using Ion Exchange Membrane)

  • 이진택
    • 대한화학회지
    • /
    • 제18권1호
    • /
    • pp.58-65
    • /
    • 1974
  • 陰陽兩이온交換樹脂膜을 利用한 電氣透析에 의하여 電解質을 濃縮할때 濃縮液의 濃度, 透析量/電氣量 및 濃縮液增加量/ion透析量과 溶液의 濃度, 電流密度와의 關係를 實驗해 보았으며 膜內의 合水率, 이온의 移動度 및 電氣透析의 流速으로 해석됨을 알았다

  • PDF

비무장지대에 인접한 경기도 농촌지역 강수의 화학적 성분에 관한 기초 연구 (A Preliminary Study on the Chemical Compositions of Precipitation in the Rural Area of Kyunggi Province near Demilitarized Zone)

  • 박국태;김창호
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.157-164
    • /
    • 1998
  • preliminary study on the chemical compositions of forty seven precipitations from March 1994 to May 1995 In Yeoncheon-gun, which Is adjacent to the southern boundary of demilitarized zone (DMZ) in the northernmost tip of Kyunggi Province has been Performed. The metal cation and anion concentrations were measured by atomic absorption spectrometer and ion chromatography, respectively. pH/lon meter and direct nesslerization method were used for the concentration measurements of $H^+$ ion and $NH_46+$ ions, respectively Based on the data, the quantitative orders of the cation and anion average concentrations were $Ca^{2+}>NH_4^+>Na^+>K^+>Mg^{2+}>H^+ and SO_4^{2+}>Cl^-> NO_3^-$, respectively..The ratio of average total anion concentration to average total cation concentration was 0.97. The average pH value of the precipitations was 5.60. These results, correlation coefficients between the ion concentrations, and monthly variations of pH value and precipitation amount are used for chemical analysis on the environmental Pollution and Pollutant sources In Yeoncheon-gun of Kyunggi province near DMZ.

  • PDF

ELECTRICAL PROPERTIES OF ELECTROCHROMIC INDIUM NITRIDE THIN FILMS PREPARED BY RF ION PLATING

  • Asai, N.;Inoue, Y.;Sugimura, H.;Takai, O.
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.276-280
    • /
    • 1999
  • Electrical properties of electrochromic (EC) InN thin films prepared by rf ion plating were studied. There was a correlation between the electrical properties and the electrochromism in the InN films, particularly, carrier concentration changes were responsible for the electrical resistivity changes of the films due to the electrochromism. These carrier concentration changes were caused by chemisorbed hydroxyl groups and protons. From these results, it was proved that the carrier concentration changes of the InN films was responsible for the electrochromism in the visible and near-infrared region.

  • PDF

Enhanced ion-exchange properties of clinoptilolite to reduce the leaching of nitrate in soil

  • Kabuba, John
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.41-52
    • /
    • 2022
  • The leaching of nitrate from soil increases the concentration of elements, such as nitrogen, phosphorus, and potassium, in water, causing eutrophication. In this study, the feasibility of using clinoptilolite as an ion-exchange material to reduce nitrate leaching in soil was investigated. Soil samples were collected from three soil depths (0 - 30, 30 - 90, and 90 - 120 cm), and their sorption capacity was determined using batch experiments. The effects of contact time, initial concentration, adsorbent dosage, pH, and temperature on the removal of NO3- were investigated. The results showed that an initial concentration of 25 mg L-1, a contact time of 120 min, an adsorbent dosage of 5.0 g/100 mL, a pH of 3, and a temperature of 30 ℃ are favorable conditions. The kinetic results corresponded well with a pseudo-second-order rate equation. Intra-particle diffusion also played a significant role in the initial stage of the adsorption process. Thermodynamic studies revealed that the adsorption process is spontaneous, random, and endothermic. The results suggest that a modification of clinoptilolite effectively reduces the leaching of nitrate in soil.

A computer simulation of ion exchange membrane electrodialysis for concentration of seawater

  • Tanaka, Yoshinobu
    • Membrane and Water Treatment
    • /
    • 제1권1호
    • /
    • pp.13-37
    • /
    • 2010
  • The performance of an electrodialyzer for concentrating seawater is predicted by means of a computer simulation, which includes the following five steps; Step 1 mass transport; Step 2 current density distribution; Step 3 cell voltage; Step 4 NaCl concentration in a concentrated solution and energy consumption; Step 5 limiting current density. The program is developed on the basis of the following assumption; (1) Solution leakage and electric current leakage in an electrodialyzer are negligible. (2) Direct current electric resistance of a membrane includes the electric resistance of a boundary layer formed on the desalting surface of the membrane due to concentration polarization. (3) Frequency distribution of solution velocity ratio in desalting cells is equated by the normal distribution. (4) Current density i at x distant from the inlets of desalting cells is approximated by the quadratic equation. (5) Voltage difference between the electrodes at the entrance of desalting cells is equal to the value at the exits. (6) Limiting current density of an electrodialyzer is defined as average current density applied to an electrodialyzer when current density reaches the limit of an ion exchange membrane at the outlet of a desalting cell in which linear velocity and electrolyte concentration are the least. (7) Concentrated solutions are extracted from concentrating cells to the outside of the process. The validity of the computer simulation model is demonstrated by comparing the computed results with the performance of electrodialyzers operating in salt-manufacturing plants. The model makes it possible to discuss optimum specifications and operating conditions of a practical-scale electrodialyzer.

Sensitivities of Salmonella typhimurium and Staphylococcus aureus to Ozonation in the Presence of Soluble Starch and Metal Ion Complex

  • Kim, Kee-Il;Kang, Suk-Nam;Lee, Ok-Hwan;Park, Jeong-Hyun
    • Food Science and Biotechnology
    • /
    • 제17권4호
    • /
    • pp.842-845
    • /
    • 2008
  • This study was carried out to investigate the bactericidal efficacy of concentration (0.1, 0.2, and 0.4 ppm) and exposure time (10 and 30 min) of ozone on bacterial reduction rate of Salmonella typhimurium KCTC 2541 and Staphylococcus aureus ATCC 13515 in the distilled water (DW), and DW supplemented with 0.2% soluble starch (SS), and metal ion (MC) using argentums (Ag) and copper (Cu). The significant bactericidal differences of S. aureus were showed in the treatments of DW and SS, respectively, at the concentration of ozone above 0.1 ppm for 10 min, comparing the respective initial bacterial counts. The bacterial reduction of S. aureus was more sensitive than that of S. typhimurum at the same concentration of ozone. The bacterial reduction rate of SS treatment was slightly lower than that of DW treatment at the same concentration of ozone (p<0.05), however, the bacterial reduction rate of strains improved in the MC treatment compared to the DW treatment at the same concentration of ozone.

등가 이온 총량에 따른 EC 추정과 이온 균형 모형 (Estimated EC by the Total Amount of Equivalent Ion and Ion Balance Model)

  • 소재우;이용범
    • 원예과학기술지
    • /
    • 제30권6호
    • /
    • pp.694-699
    • /
    • 2012
  • 본 시험은 배양액 내 EC 모형을 구명하기 위해 Rush(2005)의 기본 배양액을 설계하여 Robinson and Strokes(1959)의 등가이온총량에 따라 EC 모형을 추정하고, 양이온과 음이온 및 무기이온간의 EC 변량에 대하여 분석하였다. Steiner(1980)의 경험적 해석을 위해 작물 생육에 최적화된 국내외 130종 배양액을 사용하여 EC 추정 모형을 실증하였다. Rush(2005)의 기본 배양액을 등가이온총량으로 EC 추정한 결과 $R^2$ 값 0.96의 y = 1.33x - 0.23의 신뢰성 높은 회귀모형을 추정하였다. 양이온과 음이온의 농도 변화가 EC의 증감 변화와 일치하지만 그 평면적으로 변화하지 않고 변량폭을 보였다. 그 변화는 기존에 보고된 양이온의 영향보다 음이온의 영향이 더 큰 것으로 나타났는데, 질소 이온과 황이온에 기인한 것으로 생각된다. 이상의 EC 추정 모형을 작물 생육이 최적화된 국내외 130종의 배양액을 이용하여 재확인하였는데, $R^2$ = 0.98의 y = 1.23x - 0.02를 나타냈다. 또한 EC에 대한 양이온과 음이온의 contour 분석에서 적정 배양액 농도 범위로 알려진 EC $1.5-2.5dS{\cdot}m^{-1}$는 양이온 $11meq{\cdot}L^{-1}$ 이상, 음이온 $15meq{\cdot}L^{-1}$ 이상인 것으로 나타났다. 좌측 하단의 $1.5dS{\cdot}m^{-1}$ 저농도와 우측 하단의 $2.5dS{\cdot}m^{-1}$ 고농도에서 타원형 분포를 나타내어 적정 배양액 농도 범위에서 양이온과 음이온은 다양하게 분포하는 것으로 나타났다. 본 연구는 Steiner(1980)의 mutual ratio에서 이온 간 함량 비율에 의한 배양액 설계와 달리 EC에 대한 양이온과 음이온의 변량을 동시에 적용함으로써 이온간의 분포 특성과 적정 배양액 농도 EC $1.5-2.5dS{\cdot}m^{-1}$의 양이온과 음이온의 수준을 추정할 수 있는 EC 모형을 제시하였다.

태화강의 수질오염 특성에 관한 연구 - 화학적 산소요구량과 염소이온 농도 - (A Study on the Water Pollution Characteristics of the Taewha River - Chemical Oxygen Demand and Chloride ion Concentration -)

  • 류석환
    • 한국환경과학회지
    • /
    • 제2권4호
    • /
    • pp.291-297
    • /
    • 1993
  • The COD values and chloride ion concentrations of the Taewha river flowing through Ulsan area were determined along the main stream and the relationships between CODs and chloride ion concentrations were described. The results showed that the middle-upper stream and downstream of the Taewha river were polluted deeply with municipal sewage and self-purification occured in the middle-downstream of the river. When domestic sewage is a main source of pollutants, and is especially the only source of chloride in the stream water, the ratio of COD/[$\textrm{Cl}^{-}$] will be utilizable as a measure of self-purification of the stream.

  • PDF

The Effects of Resin Ratio and Bed Depth on the Performance of Mixed-bed Ion Exchange at Ultralow Solution

  • Yoon, Tae-Kyung;Lee, Gang-Choon;Noh, Byeong-Il
    • 한국환경과학회지
    • /
    • 제18권6호
    • /
    • pp.595-601
    • /
    • 2009
  • The effects of the cation-to-anion resin ratio and bed depth on ion exchange performance of mixed-bed were studied at ultralow solution concentration. Breakthrough curves were experimentally obtained for NaCI solution as functions of resin ratio and bed depth. The bed depth affects the pattern of the sodium breakthrough curve but not the chloride breakthrough curve in beds because of the selectivity difference. Resin selectivity determines the shape of breakthrough curves, Some sodium and chloride breakthrough curves crossed at a point as a function of resin ratio. The lower cation-to-anion resin ratio showed the higher effluent concentration or treated volume of the crossover point regardless of the total resin weight.