• Title/Summary/Keyword: Ion components

Search Result 583, Processing Time 0.031 seconds

Development of RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Jang, Du-Hui;Park, Min;Kim, Seon-Ho;Jeong, Seung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.550-551
    • /
    • 2013
  • Large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER plasmas. Negative hydrogen (deuterium) ion sources are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck- Institute for Plasma Physics, Garching) for ASDEX-U and W7-AS neutral beam injection (NBI) systems. In recent, the first NBI system (NBI-1) has been developed successfully for the KSTAR. The first and second long-pulse ion sources (LPIS-1 and LPIS-2) of NBI-1 system consist of a magnetic bucket plasma generator with multi-pole cusp fields, filament heating structure, and a set of tetrode accelerators with circular apertures. There is a development plan of large-area RF ion source at KAERI to extract the positive ions, which can be used for the second NBI (NBI-2) system of KSTAR, and to extract the negative ions for future fusion devices such as ITER and K-DEMO. The large-area RF ion source consists of a driver region, including a helical antenna (6-turn copper tube with an outer diameter of 6 mm) and a discharge chamber (ceramic and/or quartz tubes with an inner diameter of 200 mm, a height of 150 mm, and a thickness of 8 mm), and an expansion region (magnetic bucket of prototype LPIS in the KAERI). RF power can be transferred up to 10 kW with a fixed frequency of 2 MHz through a matching circuit (auto- and manual-matching apparatus). Argon gas is commonly injected to the initial ignition of RF plasma discharge, and then hydrogen gas instead of argon gas is finally injected for the RF plasma sustainment. The uniformities of plasma density and electron temperature at the lowest area of expansion region (a distance of 300 mm from the driver region) are measured by using two electrostatic probes in the directions of short- and long-dimension of expansion region.

  • PDF

Depolarizing Effectors of Bradykinin Signaling in Nociceptor Excitation in Pain Perception

  • Choi, Seung-In;Hwang, Sun Wook
    • Biomolecules & Therapeutics
    • /
    • v.26 no.3
    • /
    • pp.255-267
    • /
    • 2018
  • Inflammation is one of the main causes of pathologic pain. Knowledge of the molecular links between inflammatory signals and pain-mediating neuronal signals is essential for understanding the mechanisms behind pain exacerbation. Some inflammatory mediators directly modulate the excitability of pain-mediating neurons by contacting the receptor molecules expressed in those neurons. For decades, many discoveries have accumulated regarding intraneuronal signals from receptor activation through electrical depolarization for bradykinin, a major inflammatory mediator that is able to both excite and sensitize pain-mediating nociceptor neurons. Here, we focus on the final effectors of depolarization, the neuronal ion channels, whose functionalities are specifically affected by bradykinin stimulation. Particular G-protein coupled signaling cascades specialized for each specific depolarizer ion channels are summarized. Some of these ion channels not only serve as downstream effectors but also play critical roles in relaying specific pain modalities such as thermal or mechanical pain. Accordingly, specific pain phenotypes altered by bradykinin stimulation are also discussed. Some members of the effector ion channels are both activated and sensitized by bradykinin-induced neuronal signaling, while others only sensitized or inhibited, which are also introduced. The present overview of the effect of bradykinin on nociceptor neuronal excitability at the molecular level may contribute to better understanding of an important aspect of inflammatory pain and help future design of further research on the components involved and pain modulating strategies.

Remote Control System of Ion Implanter (이온주입장치의 원격제어시스템 구축)

  • 이재형;양대정
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1042-1047
    • /
    • 2003
  • The goal of this research is to implement a PC-based remote control system of ion implanter using Visual Basic programming. Presently, skilled process engineers are required to regularly setup and adjust implanter parameters. Any reduction in the number of production hours devoted to ion beam implanter setup or recalibration after a species change would represent substantial improvements in both manpower and equipment utilization. An optical communication system for the remote control and telemetry in the operation of the 50kev potential was designed and constructed. This system enables continuous and safe operation of the ion implanter and can be the basis for the automation. The isolation characteristics of optical fiber were 10kV/cm, and performance tests of the system under the intense noise environment during the implanter operations showed satisfactory results. This system is designed to completely replace the existing human-machine interface with many new functions. This paper describes the important components of the system including system architecture and software development. It is expected that this system can be used for the communication and control purpose in the high noise environments such as the operation of the MeV energy implanter or other high power, high noise systems.

Secondary Ion Mass Spectrometry : Theory and Recent trends (이차이온질량분석기의 원리와 분석법 동향)

  • Byeon, Mirang;Kim, Da Young;Hong, Tae Eun
    • Ceramist
    • /
    • v.22 no.4
    • /
    • pp.357-367
    • /
    • 2019
  • Secondary Ion Mass Spectrometry(SIMS) is an analytical method that measures the distribution and concentration of elements or compounds by analyzing the mass of secondary ions released by irradiating ion beams with energy of hundreds eV to 20 keV on the sample surface. Unlike other similar analytical instruments, SIMS directly detect the elemental ions that constitute a sample, allowing you to accurately identify components and obtain concentration information in the depth direction. It is also a great feature for measuring isotopes and analyzing light elements, especially hydrogen. In particular, with the development of materials science, there is an increasing demand for trace concentration analysis and isotope measurements in the micro-regions of various materials. SIMS has a short history compared to other similar methods; nevertheless, SIMS is still advancing in hardware and is expected to contribute to the development of materials science through research and development of advanced analytical techniques.

Research Trend of Polymeric Ion-Exchange Membrane for Vanadium Redox Flow Battery (바나듐계 레독스 흐름 전지용 고분자 이온교환막의 연구개발 동향)

  • Kim, Deuk Ju;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.285-300
    • /
    • 2012
  • Vanadium redox flow battery is believed to be one of important energy storage technologies, because it has many advantages, including long cycle life, high energy efficiency, low cost of maintenance, and environmental friendship. As one of the key components of vanadium redox flow battery system, an ion exchange membrane is required to prevent cross-mixing of the positive and negative electrolytes while allowing ionic continuity. However, ion exchange membrane such as Nafion using in VRBs still face some challenges in meeting performance and cost requirements for broad penetration. Therefore, to resolve these problems, developed various ion exchange membranes are investigated and compared with Nafion membranes in terms of their performance in vanadium redox flow battery.

XPS STUDY ON THE EFFECT OF LOW-ENERGY ELECTRON IRRADIATION ON DNA DAMAGE BY Fe3+ ION

  • Noh, Hyung-Ah;Park, Yeun-Soo;Cho, Hyuck
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.87-91
    • /
    • 2015
  • We have employed X-ray photoelectron spectroscopy (XPS) technique to examine the combined effects of low-energy electron (LEE) irradiation and $Fe^{3+}$ ion on DNA damage. pBR322 plasmid DNA extracted from E. coli ER2420 was used for preparing DNA-$Fe^{3+}$ sample. The C1s XPS spectra were scanned for LEE-irradiated and LEE-unirradiated samples and then curve-fitted. For the samples with LEE irradiation only or with Fe ion only, no significant changes from pure DNA samples were observed - a single effect of either $Fe^{3+}$ ion or LEE irradiation did not cause a significant damage. However, when these two components were combined, the DNA damage was increased quite significantly, compared to the sum of DNA damages caused by $Fe^{3+}$ ion and by LEE irradiation independently. This observation is consistent with our previous results [Radiat. Res. 177, 775 (2012)] which was done using gel-electrophoresis technique. Partial interpretation of the observed spectrum peaks was also attempted.

Enhancement of Life Time for PCB (Printed Circuit Board) Drill Bit by Nitrogen Ion Implantation

  • Lee, Chan-Young;Lee, Jae-Sang;Kim, Bum-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.206-208
    • /
    • 2008
  • Implantation of metals and ceramics with ions of nitrogen and other species has improved surface properties such as friction, wear and corrosion in numerous industrial applications. In recent years, PCB drills tend to be more minimized increasingly as the electronics components have been more highly accumulated and minimized. Therefore nitrogen ion implantation was performed onto PCB drill (0.15 & 0.3 mm in diameter), in order to investigate mechanical properties of WC-Co cermets surface through Nano-indentation tests. PCB drill was implanted at energy of 70 keV, 90 keV, 120 keV and with the dose range of $1{\times}10^{17}$ and $5{\times}10^{17}\;ions/cm^{2}$. After ion implantation, WC-Co PCB drill bits was tested in actual operating situation to apply cutting tools industry and is concluded that the life time of nitrogen ion implanted PCB drills is one and a half times longer than the unimplanted.

Mass Concentration and Ion Composition of Size-segregated Particulate Matter during the Non-Asian Dust Storm of Spring 2007 in Iksan (익산지역에서 봄철 비황사기간 중 입경별 대기먼지농도와 이온조성)

  • Kang, Gong-Unn;Kim, Nam-Song;Lee, Hyun-Ju
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.300-310
    • /
    • 2008
  • In order to further determine the mass concentration and ion composition of size-segregated particulate matter (PM) during the non-Asian dust storm of spring, $PM_{2.5}$ (fine particle), $PM_{10-2.5}$ (coarse particle), and $PM_{over-10}$ (PM with an aerodynamic diameter larger than $10{\mu}m$) were collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in the spring season of 2007 in the Iksan area. During the sampling period from 5 April to 21 April, a total of 34 samples for size-segregated PM were collected, and then measured for PM mass concentrations by gravimetric measurements and for water-soluble inorganic ion species by using ion chromatography. Average mass concentrations of $PM_{2.5}$, $PM_{10-2.5}$, $PM_{over-10}$ were $35.4{\pm}11.5{\mu}g/m^3$, $13.3{\pm}5.5{\mu}g/m^3$ and $9.5{\pm}4.7{\mu}g/m^3$, respectively. On average, $PM_{2.5}$ accounted for 74% of $PM_{10}$. Compared with the literature from other areas in Korea, the measured concentration of $PM_{2.5}$ were relatively high. Water-soluble inorganic ion fractions in $PM_{2.5}$, $PM_{10-2.5}$, and $PM_{over-10}$ were found to be 47.8%, 28.5%, and 14.7%, respectively. Among the water-soluble inorganic ion species, $SO_4^{2-}$, $NO_3^-$ and $NH_4^+$ were the main components in $PM_{2.5}$, while $NO_3^-$ dominantly existed in both $PM_{10-2.5}$ and $PM_{over-10}$. Non-seasalt $SO_4^{2-}$ (nss-$SO_4^{2-}$ and $NO_3^-$ were found to mainly exist as the neutralized chemical components of $(NH_4)_2SO_4$ and $NH_4NO_3$ in fine particles.

Liquid Chromatography of Aromatic Sulfonic Acids by Tetramethylammonium Bromide (Tetramethylammonium Bromide를 이용한 방향족 술폰산들의 액체크로마토그래피)

  • Oh, Hae-Beom
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.9
    • /
    • pp.793-799
    • /
    • 1993
  • Ion-pair model was predominated over ion-interaction model in the retention mechanism of analytes when tetramethylammonium bromide (TMAB) was used as a counter-ion in the investigation of aromatic sulfonic acids on the reversed-phase liquid chromatography by $C_{18}$ column as a stationary phase. The capacity factors of analytes were influenced by the type and concentration of counter-ions, concentrations of methanol and co-anion, types and position of functional group, and the pH mobile phase. Components of analyte mixture could be separated under the optimum conditions by this method.

  • PDF

A Review of Li-ion Battery Equivalent Circuit Models

  • Zhang, Xiaoqiang;Zhang, Weiping;Lei, Geyang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.311-316
    • /
    • 2016
  • Batteries are critical components of electric vehicles and energy storage systems. The connection of a battery to the power grid for charge and discharge greatly affects energy storage. Therefore, an accurate and easy-to-observe battery model should be established to achieve systematic design, simulation, and SOC (state of charge) estimations. In this review, several equivalent circuit models of representative significance are explained, and their respective advantages and disadvantages are compared to determine and outline their reasonable applications to Li-ion batteries. Numerous commonly used model parameter identification principles are summarized as well, and basic model verification methods are briefly introduced for the convenient use of such models.