Determination of Trace-Level Perchlorate by IC-MS/MS and Distribution in the Han River (IC-MS/MS를 이용한 수중의 과염소산이온 분석방법 최적화 및 한강수계내 분포조사)

  • Kim, Hyun-Hee;Han, Ihn-Sup;Jeong, Gwan-Jo;Park, Hyeon;Han, Sun-Hee;Cho, Wan-Seon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.349-356
    • /
    • 2010
  • Ion chromatography (IC) coupled with conductivity detector (CD) is a common system for the determination of perchlorate in water samples. Although the IC method with CD has been widely used for the determination of trace level perchlorate ion in water, sensitivity decreases dramatically as the complexity of the matrices increases. Here we proposed the application of ion chromatography coupled with mass spectrometry (IC-MS/MS) to significantly improve selectivity of perchlorate. The mean recovery of the method was 104.4 ${\pm}$ 5.7% and the relative standard deviation (RSD%) was 1.9 ${\pm}$ 1.3%. The alculated method detection limit (MDL) was 0.0207 ${\pm}$ 0.0099 ${\mu}g/L$. The concentrations of perchlorate were minimum <0.1 ${\mu}g/L$ and maximum 18.3 ${\mu}g/L$ in source water (Namhan, Bukhan and Han River). Hongreung showed higher concentrations ($1^{st}$-14.3 ${\mu}g/L$, $2^{st}$-18.3 ${\mu}g/L$) than the other places. And the concentrations of perchlorate were 0.18~0.34 ${\mu}g/L$ in the samples taken from the six water treatment plants and six intake stations in Seoul.

Rapid Analytical Method of Nitrite and Nitrate in Fish by Ion Chromatography

  • Oh, Myung-Cheol;Oh, Chang-Kyung;Kim, Soo-Hyun
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1996
  • Rapid analytical method was investigated to determine precursors of N-nitrosamine such an nitrite and nitrate in squid(Illex illecebrosus and Sepiell maindroni), codfish(Gadus marcrocephalus)and flatfish(Paralichthys olivaceus) by ion chromatography(IC) and colorimetric methods. Recoveries of nitrite and nitrate in fish tissues were 89~98.7% and 94.1~99.8% for IC, and 98.4~103.7% and 67.7~102.2% for colori-metric method, respectively. Using IC, nitrite was not detected and nitrate was 0.89~1.23mg/kg, while using colorimetric method, nitrite and nitrate were NO~0.08mg/kg and 0.3~0.42mg/kg, respectively. Therefore, the IC method showed better recoveries, and was applicable to extract nitrite and nitrate simultaneously, and is simpler compared with colorimetric method in analyzing nitrite and nitrate from fish tissues.

  • PDF

Determination of halogen elements in plastics by using combustion ion chromatography (연소IC를 이용한 플라스틱 중 할로겐 물질 정량)

  • Jung, Jae Hak;Kim, Hyo Kyoung;Lee, Yang Hyoung;Lee, Lim Soo;Shin, Jong Keun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.284-295
    • /
    • 2008
  • For plastics samples, a method using combustion ion chromatography was selected as a method for rapid low-cost analysis to test whether hazardous substances are contained or not. Using combustion ion chromatography, a verification test for F, Cl and Br compounds generated a linear calibration curve with a correlation coefficient of $r^2$ = 0.999~1.000 in the calibration range from 0.5 to 4.0 mg/kg. The detection limits were found to be 0.005~0.024 mg/kg and quantitative limits were found to be 0.014~0.073 mg/kg. The recoveries of combustion ion chromatography using certified reference material (CRM) were found to be 95.5~104.9%. Based on these results, a proficiency test was conducted together with several laboratories in and out of the country, to make comparative analysis of the results from each laboratory. As a result, the data supported the use of combustion ion chromatography as an effective analysis method to deal with regulations for halogen-free electronic products and for other hazardous substances in the electronic products.

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

  • Nam, Sang-Ho;Kim, Jae-Jin;Han, Soung-Sim
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1805-1808
    • /
    • 2003
  • The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method. The IC-ICP-MS technique was applied for the determination of arsenic species in a NIST SRM 1643d water sample. An As(III) only was detected in the sample. The detection limits of As(III), As(V) and DMA were 0.31, 0.45, and 2.09 ng/mL, respectively. It was also applied for the determination of arsenic species in a human urine obtained by a volunteer, and three arsenic species were identified. The determination of total As in human urines that were obtained from 25 volunteers at the different age was also carried out by ICP-MS.

Separation of Plutonium Oxidation States by Ion Chromatography (이온크로마토그래피를 이용한 산화수별 플루토늄의 분리)

  • Kim, Seung Soo;Jun, Kwan Sik;Kang, Chul Hyung
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2001
  • The ion chromatography for the separation of plutonium species which are suggested to be $Pu^{3+}$, $Pu^{4+}$, $PuO_2{^+}$ and $PuO_2{^{2+}}$ in natural water was studied. Two separation methods were performed; 1) two-column method containing each of $SiO^-$ and SiO-$SO_3{^-}$ cation exchanger, 2) IC with AG11 column and the eluent of oxalate/nitric acid. Separation conditions for $Eu^{3+}$, $Th^{4+}$, $NpO_2{^+}$, $UO_2{^{2+}}$ in place of plutonium species were acquired from preliminary tests. When these conditions were applied to separate the plutonium species, two-column method was separated them successfully. However, the IC method with oxalate eluent was difficult in the separation of plutonium species due to the change of $Pu^{3+}$ and $PuO_2{^{2+}}$ to $Pu^{4+}$ and $PuO_2{^+}$ respectively.

  • PDF

An Investigation on the Extraction and Quantitation of a Hexavalent Chromium in Acrylonitrile Butadiene Styrene Copolymer (ABS) and Printed Circuit Board (PCB) by Ion Chromatography Coupled with Inductively Coupled Plasma Atomic Emission Spectrometry

  • Nam, Sang-Ho;Kim, Yu-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1967-1971
    • /
    • 2012
  • A hexavalent chromium (Cr (VI)) is one of the hazardous substances regulated by the RoHS. The determination of Cr (VI) in various polymers and printed circuit board (PCB) has been very important. In this study, the three different analytical methods were investigated for the determination of a hexavalent chromium in Acrylonitrile Butadiene Styrene copolymer (ABS) and PCB. The results by three analytical methods were obtained and compared. An analytical method by UV-Visible spectrometer has been generally used for the determination of Cr (VI) in a sample, but a hexavalent chromium should complex with diphenylcarbazide for the detection in the method. The complexation did make an adverse effect on the quantitative analysis of Cr (VI) in ABS. The analytical method using diphenylcarbazide was also not applicable to printed circuit board (PCB) because PCB contained lots of irons. The irons interfered with the analysis of hexavalent chromium because those also could complex with diphenylcarbazide. In this study, hexavalent chromiums in PCB have been separated by ion chromatography (IC), then directly and selectively detected by inductively coupled plasma atomic emission spectrometry (ICP-AES). The quantity of Cr (VI) in PCB was 0.1 mg/kg.

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

The Application of Ion Chromatographic Method for Bioavailability and Stability Test of Iron Preparations

  • Kim, Young-Ok;Chung, Hye-Joo;Kong, Hak-Soo;Choi, Dong-Woong;Cho, Dae-Hyun
    • Archives of Pharmacal Research
    • /
    • v.22 no.3
    • /
    • pp.288-293
    • /
    • 1999
  • Postabsorptive serum iron level was determined after oral administration of the compounds to human. In serum and whole blood, $Fe^{3+}$ was measured by ion chromatography (IC) using a pyridine-2,6-dicarboxylic acid (PDCA) as an eluent. The serum sample solutions were pretreated with I N HCI and 50% TCA. The whole blood sample solutions were treated with 3 N HCI for 30 min at $125^{\circ}C$. The limit of detection (LOD) of the IC technique is $0.2 {\mu}M$ for$Fe^{2+}$and 0.1 $\mu$M for $Fe^{3+}$. The area under concentration (AUC) can be obtained by the above analytical condition. In addition, to compare the stability of $Fe^{2+}$ to that of $Fe^{3+}$ in pharamaceutical preparations, accelerated stability test was carried out. After storing the samples under $40^{\circ}C$, 75%RH in light-resistant container for various time intervals, the contents of iron of different valencies were determined separately by the IC technique and the change and/or the interchange of among those iron species in preparations was investigated. Iron raw materials are stable, but $Fe^{2+}$ in$Fe^{3+}$ source materials was slightly converted to $Fe^{3+}$ by oxidation. $Fe^{2+}$ in$Fe^{3+}$ source raw materials and $Fe^{3+}$ in $Fe^{2+}$ raw materials are determined as impurities. Therefore, IC technique is found to be an appropriate method for comparative evaluation of dissimilar bioavailability of $Fe^{2+}$ and $Fe^{3+}$, stability of $Fe^{2+}$ and $Fe^{3+}$ raw materials and preparations.

  • PDF

Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter (Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가)

  • Shin, Yong Chul;Oh, Se Min;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF

A Study of the Potential Interference of ArC+ on the Direct Determination of Trivalent Chromium and Hexavalent Chromium Using Ion Chromatography Coupled with ICP-MS

  • Nam, Sang-Ho;Park, Young-Il;Kim, Jae-Jin;Han, Sun-Ho;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.447-451
    • /
    • 2004
  • Low and high resolution inductively coupled plasma mass spectrometry (ICP-MS) coupled with ion chromatography (IC) has been investigated for speciation of Cr(III) and Cr(VI). In particular, the interference of ArC^+formed by the carbon in a sample on the simultaneous determination of Cr(III) and Cr(VI) has been studied. In chemical speciation, this study shows that quadrupole type ICP-MS with low resolution has a limitation of simultaneous determination fo chromium species if the sample contains the carbon elements. The interference problems can be solved by high resolution ICP-MS.