• 제목/요약/키워드: Ion Irradiation

검색결과 453건 처리시간 0.027초

이온빔 조사 각도와 에너지강도에 의한 수직 배향막의 특성 분석 (Characteristic Analysis of Vertical Alignment by Ion-beam Irradiation Angle and Energy Density)

  • 강동훈;오병윤;김병용;한진우;김영환;옥철호;한정민;이상극;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.398-398
    • /
    • 2007
  • The Liquid Crystal (LC) alignment uniformity is very important in LC devices. The alignment mechanism of LC molecules on a rubbed polyimide (PI) surface is very important for both LC fundamental research and application. So, Generally a rubbing method to align LC has been widely used to mass-produce LCD panels. But because rubbing method is contact method between rubbing fabric and indium-tin-oxide glass or flexible substrate, rubbing method has some defects, such as the electrode charges and the creation of contaminating particles. Thus we strongly recommend a non-contact alignment technique for getting rid of some defects of rubbing method. Most recently, the LC aligning capabilities achieved by ion-beam exposure on the organic and nonorganic thin film surface have been reported successfully. In this research, we studied the tilt angle generation and electro-optical performances for a NLC on homeotropic polyimide surfaces with ion-beam exposure. The LC aligning capabilities of a nematic liquid crystal (NLC) on a homeotropic PI surface using a new ion-beam method were studied. On the homeotropic PI surface, the tilt angle of the NLC by exposure ion-beam had a tendency to decrease as increased ion-beam energy density. And, on the homeotropic PI surface, the alignment character of the NLC with respect to ion-beam energy was good. And we achieved satisfactory result for EO character.

  • PDF

아르곤 이온빔 조사로 형성된 주름진 PDMS 표면 경화층의 이질성 (Heterogeneity of hard skin layer in wrinkled PDMS surface fabricated by Ar ion beam irradiation)

  • Lee, Seunghun;Byeon, Eunyeon;Kim, Do-Geun;Jung, Sunghoon
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.43.1-43.1
    • /
    • 2018
  • Spatial distribution of binding state in depth direction is investigated in a hard skin layer on soft polydimethylsiloxane (PDMS) fabricated by Ar ion beam irradiations. The hard skin layer known as a silica-like homogenous layer was composed of two layers. Impinging Ar ions transfer energy to PDMS as a function of collisional energy transfer rate, which is the maximum at surface and decreases gradually as an ion penetrates. This formed the heterogeneous hard skin layer that consists of a top-most layer and an intermediate layer. XPS depth profiling showed the existence of the top-most layer and intermediate layer. In the top-most layer, scission and cross-linking were occurred simultaneously and Si-O bond showed dissociated status, SiOx (x = 1.25 - 1.5). Under the top-most layer, there was the intermediate layer in which cross-linking is mainly occurred and Si-O bond showed silica-like binding status, SiOx (x = 1.75 - 2). And theoretical analysis which calculates the collisional energy transfer and a displacement per atom explained the thickness variation of top-most layer according to Ar ion energy from 360 eV to 840 eV.

  • PDF

Radiation damage in helium ion-irradiated reduced activation ferritic/martensitic steel

  • Xia, L.D.;Liu, W.B.;Liu, H.P.;Zhang, J.H.;Chen, H.;Yang, Z.G.;Zhang, C.
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.132-139
    • /
    • 2018
  • Nanocrystalline reduced activation ferritic/martensitic (RAFM) steel samples were prepared using surface mechanical attrition treatment (SMAT). Un-SMATed and SMATed reduced activation ferritic/martensitic samples were irradiated by helium ions at $200^{\circ}C$ and $350^{\circ}C$ with 2 dpa and 8 dpa, respectively, to investigate the effects of grain boundaries (GBs) and temperature on the formation of He bubbles during irradiation. Experimental results show that He bubbles are preferentially trapped at GBs in all the irradiated samples. Bubble denuded zones are clearly observed near the GBs at $350^{\circ}C$, whereas the bubble denuded zones are not obvious in the samples irradiated at $200^{\circ}C$. The average bubble size increases and the bubble density decreases with an increasing irradiation temperature from $200^{\circ}C$ to $350^{\circ}C$. Both the average size and density of the bubbles increase with an increasing irradiation dose from 2 dpa to 8 dpa. Bubbles with smaller size and lower density were observed in the SMATed samples but not in the un-SMATed samples irradiated in the same conditions, which indicate that GBs play an important role during irradiation, and sink strength increases as grain size decreases.

In vitro and in vivo Biological Responses of Proton Irradiation from MC-50 Cyclotron

  • Jung, Uhee;Eom, Hyeon Soo;Jeong, Kwon;Park, Hae-Ran;Jo, Sung-Kee
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.223-229
    • /
    • 2012
  • In this study, we investigated the biological damage and stress responses induced by ion beam (proton beam) irradiation as a basis for the development of protective measures against space radiation. We examined the biological effects of proton beam produced by MC-50 cyclotron at KIRAMS on the cultured cells and mice. The proton beam energy used in this study was 34.9 MeV and the absorption dose rate for cells and mice were $0.509Gy\;sec^{-1}$ and $0.65Gy\;sec^{-1}$, respectively. The cell survival rates measured by plating efficiency showed the different sensitivity and dose-relationship between CHO cells and Balb/3T3 cells. HGPRT gene mutation frequency in Balb/3T3 was $15{\times}10^{-6}Gy^{-1}$, which was similar to the reported value of X-ray. When stress signaling proteins were examined in Balb/3T3 cells, $I{\kappa}B-{\alpha}$ decreased markedly whereas p53, phospho-p53, and Rb increased after proton beam irradiation, which implied that the stress signaling pathways were activated by proton beam irradiation. In addition, cellular senescence was induced in IMR-90 cells. In the experiments with C57BL/6 mouse, the immune cells (white blood cells, lymphocytes) in the peripheral blood were greatly reduced following proton beam irradiation whereas red blood cells and platelets showed relatively little change. These results can be utilized as basic data for studying the biological effects of proton beam using MC-50 cyclotron with respect to proton therapy research as well as space radiation research.

하향 초음파 조사 시스템에서의 초음파 화학적 및 물리적 효과 평가 (Sonochemical and Sonophysical Effects in a Downward-Irradiation Sonoreactor)

  • 김슬기;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권3호
    • /
    • pp.23-31
    • /
    • 2020
  • The performance of a downward-irradiation sonoreactor was investigated using calorimetry, KI dosimetry, luminol (Sonochemiluminescence, SCL) method, and aluminium foil erosion method as one of the basic steps for the optimal design of downward-irradiation sonoreactors. The applied frequency was 28 kHz and the input electrical power was 280 - 300 W. The liquid height, from the reactor bottom to the transducer module surface, ranged from 1λ (53.6 mm) to 2λ (107.1 mm). For various liquid heights, the magnitude of calorimetric power and the mass of cavitation-generated I3- ion varied significantly. It was found that the additional application of mechanical mixing resulted in higher sonochemical activity, especially in the cavitational active zone, which was induced by violent liquid flow in the reactor. In aluminium foil erosion tests, it was found that less ultrasound energy reached the bottom of the reactor due to the violent liquid flow and no significant sonophysical effect was observed for higher mixing rate conditions (100 and 200 rpm).

PHOTOCHEMICAL REACTION OF CHLOROFORM

  • Park, Hyoung-Ryun;Jeong, Young-Tae;Ko, Song-Kyong;Oh, Jong-Hoon;Ham, Heui-Suk
    • Journal of Photoscience
    • /
    • 제4권1호
    • /
    • pp.17-21
    • /
    • 1997
  • The photochemical reactions of the neat chloroform and the aqueous chloroform in the absence (saturated with argon) and presence of 02 (saturated with air or oxygen) have been investigated using 184.9 nm UV light. The irradiation of the deoxygenated neat chloroform causes the formation of hexachloroethane, pentachloroethane, and 1, 1, 2, 2-tetrachloroethane. The initial quantum yields of the products were determined to be 6.37 x 10$^{-4}$, 4.04 x 10$^{-4}$ and 1.76 x 10$^{-4}$, respectively. In the irradiation of aqueous chloroform, chloride ion was also formed along with the products listed above and 1, 1, 2, 2-tetrachloroethane was the predominant product among the chlorinated organic products, which contrasts to the case of the neat chloroform. The presence of oxygen during the irradiation of aqueous chloroform had an effect on the yield of the products. With increasing the concentration of oxygen, the formation of the products was decreased. Probable reaction mechanisms for the photochemical reaction were presented on the basis of products analysis.

  • PDF

Effects of α-particle beam irradiation on superconducting properties of thin film MgB2 superconductors

  • Kim, Sangbum;Duong, Pham van;Ha, Donghyup;Oh, Young-Hoon;Kang, Won Nam;Hong, Seung Pyo;Kim, Ranyoung;Chai, Jong Seo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.8-13
    • /
    • 2016
  • Superconducting properties of thin film MgB2 superconductors irradiated with 45 MeV ${\alpha}$-particle beam were studied. After the irradiation, enhancement of the critical current density and pinning force was observed, scaling close to strong pinning formula. Double logarithmic plots of the maximum pinning force density with irreversible magnetic field show a power law behavior close to carbon-doped MgB2 film or polycrystals. Variation of normalized pinning force density in the reduced magnetic field suggests scaling formulas for strong pinning mechanism like planar defects. We also observed a rapid decay of critical current density as the vortex lattice constant decreases, due to the strong interaction between vortices and increasing magnetic field.

LC Aligning Capabilities of a Nematic Liquid Crystal on Homeotropic Polyimide Surface by New Ion-beam Irradiation

  • Ok, Chul-Ho;Kang, Dong-Hun;Lee, Kang-Min;Han, Jin-Woo;Kim, Byoung-Yong;Oh, Byeong-Yun;Kim, Young-Hwan;Hwang, Jeong-Yeon;Lee, Sang-Keuk;Han, Jeong-Min;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.265-267
    • /
    • 2007
  • The liquid crystal(LC) aligning capabilities of a nematic liquid crystal(NLC) on a homeotropic polyimide(PI) surface using a new ion-beam method were studied. Exposure ion-beam of $45^{\circ}$ incidence angle shows a good LC alignment of the NLC on the homeotropic PI surface. Also, on the homeotropic PI surface, the tilt angle of the NLC by exposure ion-beam of $45^{\circ}$ incidence angle had a tendency to decrease as increased ion-beam energy density. And, on the homeotropic PI surface, the alignment character of the NLC with respect to ion-beam energy was good at 1500 eV. And we achieved satisfactory result for EO character.

방사선 그라프트 중합법을 이용한 이온교환 필터의 살균효과 (Sterilization Effect of the Ion-exchanger Filter Using by Radiation Graft Polymerization)

  • 김예진;홍용철;김민
    • Korean Chemical Engineering Research
    • /
    • 제52권3호
    • /
    • pp.378-381
    • /
    • 2014
  • 방사선 그라프트 중합에 의한 이온교환필터를 이용하여 물에 포함된 미생물의 살균 효과를 연구하였다. 이온교환필터는 부직포 필터에 전자선을 조사한 후, GMA를 그라프트 중합시켰으며, 이 GMA 필터에 이온교환기를 도입시켜 이온교환필터(EtA, DEA, SS)를 도입하였다. 그 결과 이온교환기 밀도는 EtA의 경우 2.38 mol/kg, DEA는 1.79 mol/kg, SS는 0.75 mol/kg으로 나타났다. 이렇게 제작된 필터를 통해 E. coli의 살균력을 측정하였다. SS-diol 필터의 경우 log 4.65로 EtA, DEA에 비해 각각 약 3.00배, 1.10배 높은 제거율이 나타났다. 이는 상수처리 기준 3000 CFU/ml와 비교하여 우수한 결과를 나타냈음을 알 수 있었다.

이온빔 에너지와 유기절연막 사용에 의한 액정 배향 연구 (Investigation of LC Alignment Using Ion-beam and Overcoat Layer)

  • 김병용;박홍규;이강민;오병윤;강동훈;한진우;김영환;한정민;김종환;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.370-370
    • /
    • 2007
  • The liquid crystal (LC) aligning capabilities treated on the Organic overcoat thin film surfaces by ion beam irradiation and rubbing method was successfully studied for the first time. The Organic overcoat layer was coated by spin-coating. In order to characterize the LC alignment, the microscope, pretilt angle, thermal stress, and atomic force microscopy (AFM) image was used. The good LC aligning capabilities treated on the Organic overcoat thin film surfaces with ion beam exposure of $45^{\circ}$ above ion beam energy density of 1200 eV can be achieved. But, the alignment of defect of NLC on the Organicovercoat surface at low energy density of 600 eV was measured. The pretilt angle of NLC on the Organic overcoat thin film surface with ion beam exposure of $45^{\circ}$ for 1 min at energy density of 1800eV was measured about 1.13 degree. But, low pretilt angles of NLC on the Organic overcoat thin film surface with ion beam exposure at energy density of 600, 1200, 2400, and 3000 eV was measured. Also, the pretilt angle of NLC on the rubbed Organic overcoat thin film surfaces was measured about 0.04 degrees. Finally, the good thermal stability of LC alignment on the Organic overcoat thin film surface with ion beam exposure of $45^{\circ}$ for 1 min can be measured.

  • PDF