• Title/Summary/Keyword: Ion Beam Analysis

Search Result 272, Processing Time 0.027 seconds

Chlorine effect on ion migration for PCBs under temperature-humidity bias test (고온고습 전원인가 시험에서 Cl에 의한 이온 마이그레이션 불량)

  • Huh, Seok-Hwan;Shin, An-Seob
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.47-53
    • /
    • 2015
  • By the trends of electronic package to be more integrative, the fine Cu trace pitch of organic PCB is required to be a robust design. In this study, the short circuit failure mechanism of PCB with a Cl element under the Temperature humidity bias test ($85^{\circ}C$/85%RH/3.5V) was examined by micro-structural study. A focused ion beam (FIB) and an electron probe micro analysis (EPMA) were used to polish the cross sections to reveal details of the microstructure of the failure mode. It is found that $CuCl_x$ were formed and grown on Cu trace during the $170^{\circ}C$/3hrs and that $CuCl_x$ was decomposed into Cu dendrite and $Cl_2$ gas during the $85^{\circ}C$/85%RH/3.5V. It is suggested that Cu dendrites formed on Cu trace lead to a short circuit failure between a pair of Cu traces.

Application of multimodal surfaces using amorphous silicon (a-Si) thin film for secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS)

  • Kim, Shin Hye;Lee, Tae Geol;Yoon, Sohee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.384.1-384.1
    • /
    • 2016
  • We reported that amorphous silicon (a-Si) thin film provide sample plate exhibiting a multimodality to measure biomolecules by secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS). Kim et al.1 reported that a-Si thin film were suitable to detect small molecules such as drugs and peptides by SIMS and LDI-MS. Recently, bacterial identification has been required in many fields such as food analysis, veterinary science, ecology, agriculture, and so on.2 Mass spectrometry is emerging for identifying and profiling microbiology samples from its advantageous characters of label-free and shot-time analysis. Five species of bacteria - S. aureus, G. glutamicum, B. kurstaki, B. sphaericus, and B. licheniformis - were sampled for MS analysis without lipid extraction in sample preparation steps. The samples were loaded onto the a-Si thin film with a thickness of 100 nm which did not only considered laser-beam penetration but also surface homogeneity. Mass spectra were recorded in both positive and negative ionization modes for more analytical information. High reproducibility and sensitivity of mass spectra were demonstrated in a mass range up to mass-to-charge ratio(m/z) 1200 by applying the a-Si thin film in mentioned above MS. Principle component analysis (PCA) - a popular statistical analysis widely used in data processing was employed to differentiate between five bacterial species. The PCA results verified that each bacterial species were readily distinguished and differentiated effectively from our MS approach. It shows a new opportunity to rapid bacterial profiling and identification in clinical microbiology. More details will be discussed in the presentation.

  • PDF

Development and Characterization of High Temperature Superconducting Wire for Superconducting Cable System (초전도 케이블용 고온초전도 선재의 개발 및 특성평가)

  • Mean, Byoungjean;Lee, Jae-Hun;Kim, Young-Soon;Lee, Hunju;Moon, Seung-Hyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.151-156
    • /
    • 2015
  • In order to improve the properties of high-temperature superconducting wire for superconducting cable system, we optimized the electro-polishing (EP), ion-beam assisted deposition (IBAD), superconducting (SC) layer, and baking (heat) treatment. The buffer layer was deposited on electro-polished substrate with RMS roughness ($R_{RMS}$) less than 5 nm. The IBAD process was carried out at $V_{beam}$: 1100 V and $V_{accel}$: 850 V that resulted in highly crystalline film of $LaMnO_3$. Chemical composition of SC layer is key to higher critical current, and we found that composition can be determined by surface color of SC layer. We adopt a proprietary contorl system based on RGB analysis of the surface and achieved critical current of 150 A/4 mm-width. The proposed baking treatment resulted in decreasing of about 10% of fraction defects.

RRT Study for the Quantitative Analysis of Boron in Silicon (실리콘에 도핑된 붕소의 정량분석에 대한 공동분석연구)

  • 김경중;김현경;문대원;홍태은;정칠성;김이경;김재남;임철호;김정호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.4
    • /
    • pp.218-224
    • /
    • 2002
  • A domestic round robin test(RRT) for the quantitative analysis of minor impurities was performed by a standard procedure and standard reference material. The certified reference material(CRM)s for B-doped Si thin film and analysis specimens and the analysis specimens were prepared by an ion beam sputter deposition method. These samples were certified by inductively coupled plasma mass spectrometry(ICP-MS) with isotope dilution method which il one of the most quantitative methods in chemical analysis. By using an international standard procedure(ISO/DIS-l4237) for the quantitative analysis of B in Si by SIMS, a domestic RRT was performed for these specimens. Although only a few laboratories participated in this RRT, the average B concentration well agreed with the certified value within 2% error.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Interface study of ion irradiated Cu/Ni/Cu(001)/Si thin film by X-ray reflectivity (이온 조사된 Cu/Ni/Cu(001)/Si 자성박막에 있어서 X-ray reflectivity를 이용한 계면 연구)

  • Kim, T.G.;Song, J.H.;Lee, T.H.;Chae, K.H.;Hwang, H.M.;Jeon, G.Y.;Lee, J;Jeong, K.;Whang, C.N.;Lee, J.S.;Lee, K.B.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.5
    • /
    • pp.184-188
    • /
    • 2002
  • The Cu/Ni/Cu(002)/Si(100) films which have perpendicular magnetic anisotropy were deposited by e-beam evaporation methods. From the reflection high energy electron diffraction pattern, the films were confirmed to be grown epitaxially on silicon. After 2X lots ions/$\textrm{cm}^2$ C+ irradiation, magnetic easy-axis was changed from surface normal to in-plane as shown in the hysteresis loop of magneto-optical Kerr effects. It became manifest from analysis of X-ray reflectivity and grazing incident X-ray diffraction that even though interface between top Cu layer and Ni layer became rougher, the contrast of Cu and Ni's electron density became manifest after ion irradiation. In addition, the strain after deposition of the films was relaxed after ion irradiation. Strain relaxation related with change of magnetic properties and mechanism of intermixed layer's formation was explained by thermo-chemical driving force due to elastic and inelastic collision of ions.

Theoretical analysis of erosion degradation and safety assessment of submarine shield tunnel segment based on ion erosion

  • Xiaohan Zhou;Yangyang Yang;Zhongping Yang;Sijin Liu;Hao Wang;Weifeng Zhou
    • Geomechanics and Engineering
    • /
    • v.37 no.6
    • /
    • pp.599-614
    • /
    • 2024
  • To evaluate the safety status of deteriorated segments in a submarine shield tunnel during its service life, a seepage model was established based on a cross-sea shield tunnel project. This model was used to study the migration patterns of erosive ions within the shield segments. Based on these laws, the degree of deterioration of the segments was determined. Using the derived analytical solution, the internal forces within the segments were calculated. Lastly, by applying the formula for calculating safety factors, the variation trends in the safety factors of segments with different degrees of deterioration were obtained. The findings demonstrate that corrosive seawater presents the evolution characteristics of continuous seepage from the outside to the inside of the tunnel. The nearby seepage field shows locally concentrated characteristics when there is leakage at the joint, which causes the seepage field's depth and scope to significantly increase. The chlorine ion content decreases gradually with the increase of the distance from the outer surface of the tunnel. The penetration of erosion ions in the segment is facilitated by the presence of water pressure. The ion content of the entire ring segment lining structure is related in the following order: vault < haunch < springing. The difference in the segment's rate of increase in chlorine ion content decreases as service time increases. Based on the analytical solution calculation, the segment's safety factor drops more when the joint leaks than when its intact, and the change rate between the two states exhibits a general downward trend. The safety factor shows a similar change rule at different water depths and continuously decreases at the same segment position as the water depth increases. The three phases of "sudden drop-rise-stability" are represented by a "spoon-shaped" change rule on the safety factor's change curve. The issue of the poor applicability of indicators in earlier studies is resolved by the analytical solution, which only requires determining the loss degree of the segment lining's effective bearing thickness to calculate the safety factor of any cross-section of the shield tunnel. The analytical solution's computation results, however, have some safety margins and are cautious. The process of establishing the evaluation model indicates that the secondary lining made of molded concrete can also have its safety status assessed using the analytical solution. It is very important for the safe operation of the tunnel and the safety of people's property and has a wide range of applications.

Analysis on Design and Fabrication of High-diffraction-efficiency Multilayer Dielectric Gratings

  • Cho, Hyun-Ju;Lee, Kwang-Hyun;Kim, Sang-In;Lee, Jung-Hwan;Kim, Hyun-Tae;Kim, Won-Sik;Kim, Dong Hwan;Lee, Yong-Soo;Kim, Seoyoung;Kim, Tae Young;Hwangbo, Chang Kwon
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.125-133
    • /
    • 2018
  • We report an in-depth analysis of the design and fabrication of multilayer dielectric (MLD) diffraction gratings for spectral beam combining at a wavelength of 1055 nm. The design involves a near-Littrow grating and a modal analysis for high diffraction efficiency. A range of wavelengths, grating periods, and angles of incidence were examined for the near-Littrow grating, for the $0^{th}$ and $-1^{st}$ diffraction orders only. A modal method was then used to investigate the effect of the duty cycle on the effective indices of the grating modes, and the depth of the grating was determined for only the $-1^{st}$-order diffraction. The design parameters of the grating and the matching layer thickness between grating and MLD reflector were refined for high diffraction efficiency, using the finite-difference time-domain (FDTD) method. A high reflector was deposited by electron-beam evaporation, and a grating structure was fabricated by photolithography and reactive-ion etching. The diffraction efficiency and laser-induced damage threshold of the fabricated MLD diffraction gratings were measured, and the diffraction efficiency was compared with the design's value.

The Influence of Volume Effect in 2D-array Ion Chamber on the Measurement of IMRT Dose Distribution (2차원 배열형 이온함의 부피효과가 세기조절방사선치료의 선량분포 측정에 미치는 영향)

  • Kim, Sung Joon;Lee, Seoung Jun;Park, In Kyu;Lee, Jeong Eun;Park, Shin Hyung;Seol, Ki Ho;Kim, Jae Chul
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • We evaluated the influence of volume effect on the measurement of IMRT dose distribution by comparing a 2D-array ion chamber and other dosimeters. Matrix phantom which is a 2D-array ion chamber having volume effect was compared with beam image system and film for the measurement of dose distribution. Five intensity-modulated radiation therapy plans were created using five fields in thevirtual phantom. The measured dose distribution was compared with the calculated one by radiation treatment planning system and analysis program. We evaluated the conformity of dose distribution by calculating correlation coefficients and gamma values. The highest error rate of 1.3% was associated with matrix phantom in which volume effect in small field sizes was substantial.

Nano Scale Compositional Analysis by Atom Probe Tomography: I. Fundamental Principles and Instruments (Atom Probe Tomography를 이용한 나노 스케일의 조성분석: I. 이론과 설비)

  • Jung, Woo-Young;Bang, Chan-Woo;Gu, Gil-Ho;Park, Chan-Gyung
    • Applied Microscopy
    • /
    • v.41 no.2
    • /
    • pp.81-88
    • /
    • 2011
  • Even though importance of nano-scale structure and compositional analysis have been getting increased, existing analysis tools have been reached to their limitations. Recent development of Atom Probe Tomography (APT), providing 3-dimensional elemental distribution and compositional information with sub-nm scale special resolution and tens of ppm detection limit, is one of key technique which can overcome these limitations. However, due to the fact that APT is not well known yet in the domestic research area, it has been rarely utilized so far. Therefore, in this article, the theoretical background of APT was briefly introduced with sample preparation to help understanding APT analysis.