• Title/Summary/Keyword: Iodine

Search Result 1,222, Processing Time 0.022 seconds

Iodine Deposition onto the Chinese Cabbage (요오드의 배추에 대한 침적)

  • Lee, Han-Soo;Choi, Heui-Joo;Kang, Hee-Suk;Yu, Dong-Han;Keum, Dong-Kwon;Lim, Kwang-Mook;Park, Hyo-Kook;Choi, Yong-Ho;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.3
    • /
    • pp.173-177
    • /
    • 2004
  • The Chinese cabbage, being one of the principal foodstuffs in Asian countries, is tested for iodine exposure. As a radioactive source, iodine-125 of which the radiological half life is 60 days was used to measure the concentration change. Experiments were carried out four times with different times of exposure. The iodine source was prepared by the chemical reaction of NaI in order to avoid producing relatively large iodine which might be generated In the case of crystal evaporation. The deposition velocity was obtained from the integrated air concentration and surface concentration of the Chinese cabbage. The environmental half life was also calculated.

X-ray Absorption Spectra Analysis for the Investigation of the Retardation Mechanism of Iodine Migration by the Silver Ion Added to Bentonite (벤토나이트에 첨가한 은 이온에 의한 아이오딘 이동 저지 메커니즘 규명을 위한 X-선 흡수 스펙트라 분석)

  • Kim, Seung-Soo;Kim, Min-Gue;Baik, Min-Hoon;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.201-205
    • /
    • 2010
  • Most of iodine was captured by the block when NaI solution flowed through a bentonite block sorbed silver to retard the migration of iodine released from high-level radioactive wastes. In order to understand in detail the mechanism for the retardation of the iodine by the silver ion, X-ray Absorption Near Edge Structure (XANES) and Extended X-ray Absorption Fine Structure (EXAFS) spectra of the silver sorbed bentonite before and after the contact with iodide were compared with those of AgO, $Ag_2O$ and AgI as references. This examination suggests that the silver ion sorbed on the bentonite is desorbed, and then it retards the migration of iodine by forming the cluster of AgI precipitate.

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

Nasolacrimal Duct Obstruction after Radioactive Iodine Therapy for Thyroid Cancer (갑상선암에서 방사성 요오드 치료 후 발생한 코눈물길 폐쇄)

  • Hwang, Moon Won;Lee, Eung;Yang, Jae Wook
    • Journal of The Korean Ophthalmological Society
    • /
    • v.55 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose: To investigate the clinical manifestation of nasolacrimal duct obstruction after radioactive iodine therapy for thyroid cancer. Methods: The authors examined 622 patients who were treated with radioactive iodine therapy after the operation for thyroid cancer from January 2009 to December 2011. Fourteen patients (18 eyes) were diagnosed nasolacrimal duct obstruction based on the lacrimal irrigation test, lacrimal probing test and dacryocystography in our oculoplastic clinic. We analyzed the dose of radioactive iodine therapy, number of treatments, clinical manifestation and treatment type by retrospectively reviewing the patients' medical records. Results: The mean radioactive iodine dose ($215.7{\pm}23.1mCi$, p = 0.01) and the mean number of treatments ($1.36{\pm}0.50$, p < 0.001) were significantly greater in 14 patients who had nasolacrimal duct obstruction than in patients who did not. The average onset of tearing symptoms occurred 10.2 months after radioactive iodine therapy. The mean time between correct diagnosis and therapy was 18.4 months. Three patients (3 eyes) had occlusion at the common cannaliculus and 11 patients (15 eyes) had occlusion at the nasolacrimal duct. Ten patients (13 eyes) underwent endonasal dacryocystorhinostomy for complete obstruction and 4 patients (5 eyes) underwent silicone tube intubation for partial obstruction. Conclusions: Nasolacrimal duct obstruction is a rare complication associated with radioactive iodine therapy for thyroid cancer, thus, clinicians should be aware of this complication and refer patients with symptoms of epiphora to the oculoplastic department for specialized evaluation and treatment.

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Determination of volatile and residual iodine during the dissolution of spent nuclear fuel (사용 후 핵연료 용해 중 휘발 및 잔류 요오드 분석)

  • Kim, Jung Suk;Park, Soon Dal;Jeon, Young Shin;Ha, Young Keong;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.395-406
    • /
    • 2009
  • The determination of iodine in the spent nuclear fuel and the volatile behavior during its acid dissolution have been studied by NAA(neutron activation analysis) and electron probe microanalysis (EPMA). Simulated spent fuels (SIMFUELs) were dissolved in $HNO_3$(1+1) at $90^{\circ}C$ for 8 hours. The iodine remained in a dissolver solution after dissolution, and that condensed in dissolution apparatus and trapped in the adsorbent by volatilization during the dissolution were determined, respectively. The condensed iodine was recovered by the redistillation with $HNO_3$(1+1) after transfer of the dissolver solution. The iodines in the dissolver and redistilled solution were separated by solvent extraction followed by ion exchange or precipitation method and determined by RNAA (radiochemical neutron activation analysis). The ion exchange column and filtration kit used for the isolation of iodine, which were prepared with a polyethylene tube, were used as an insert in the pneumatic tube for neutron irradiation. The iodine volatilized during the dissolution of SIMFUELs was collected in a trapping tube containing Ag-silica gel (Ag-impregnated silica gel) adsorbent, and the distribution of iodine trapped in the adsorbents were determined by EPMA. The adsorbing characteristics shown with the SIMFUELs were compared with those shown with a real spent fuel from the nuclear power plant.

Observation on The Frequency of Chromosomal Aberration and Changes in Number of Peripheral Lymphocytes in Radioactive Iodine Treatment (방사성옥소 투여에 따른 말초혈액 림프구 수의 변화 및 염색체이상 빈도의 관찰)

  • Koo, Chun-Hee;Shin, Min-Ho;Park, Young-Ju;Lee, Jung-Yim;Park, Tae-Yong;Lee, Jae-Yong;Kim, Chong-Soon;Han, Seung-Soo;Kim, Kwang-Hoe;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.343-349
    • /
    • 1995
  • Background : For biological dosimetry of radiation exposure, both observing hematologic change and calculating Ydr by chromosomal analysis as biological indicators are widely used. However, due to the lack of studies on biological dosimetry of radiation dose absorbed in the body such as in the cases of radioactive iodine therapy, the maximal and safe dose is not well known, nor is the extent to which the body can safely endure radiation exposure. Purpose : To investegate the practical applicability of hematologic changes and Ydr as an indicator for estimating radiation exposure, to patients with thyroid diseases after doses of radioactive iodine. Material and Methods : 5 patients with hyperthyroidism and 35 patients who have had thyroid cancer operation were under treatment with radioactive iodine, changes in number of lymphocytes were tracked and Ydr was calculated for more than 2 months by chromosomal analysis in peripheral lymphocytes. Results ; 1) The number of lymphocytes began to decrease 2 weeks after doses of radioactive iodine, and reached the nadir after 6 and 8 weeks, then gradually recovered. 2) The nadir count of lymphocytes was reversely correlated with the administered dosage of radioactive iodine. 3) Ydr was generally stable between 2 and 8 weeks. 4) The maximal value of Ydr was correlated with the administered dosage of radioactive iodine. 5) Ydr value at the 2nd week increased with augmented dosage of radioactive iodine. 6) Ydr value at the 2nd week was correlated with fall of lymphocyte count. Conclusion : Patients must be closely observed, because temporary bone marrow suppression and slight chromosomal aberration can be produced by even generally used dosages of radioactive iodine for diagnosis and therapy. Maximal percent fall of lymphocyte count, Ydr at the 2 week interval and maximal Ydr can be used as the biological predictor of administered dosage of radioactive iodine.

  • PDF