• Title/Summary/Keyword: Inverter type

Search Result 849, Processing Time 0.028 seconds

Clinical Application of Inverter type X-ray Generator (Inverter 방식(方式) X선장치(X線裝置)의 임상응용(臨床應用))

  • Lee, Sun-Sook;Huh, Joon;Lee, Jea-Won;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Inverter type X-ray apparatus has been introduced and used several hospitals. Principle of inverter type X-ray generators are such as to convert the frequency of commercial power supply to high frequency and to control the high voltages for X-ray tube. Inverter generators are now on the way for futher development to elliminate single phase generators and three phase generators. We compared inverter type X-ray apparatus with conventional single phase 2 peak and three phase 12 peak, apparatus in the following aspects X-ray out put to tube voltage, linearity of X-ray out put to mA, HVL according to mA contrast to kV.

  • PDF

The Performance Evaluation Analysis of PV System for Arch and Flat-Plate Type (평판형 및 아치형 태양광발전 시스템의 성능평가 분석)

  • Piao, Zheng-Guo;Choi, Youn-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1012-1018
    • /
    • 2015
  • The studies on the operating performance analysis or design about the fixed tilt angle flat-plate photovoltaic (PV) system are still lively going off. However the operating property analysis about the arch type PV system which means PV array were designed as round type is dissatisfied. In this paper, we theoretically established the factors which are cause of the deterioration in performance of arch type PV system. In addition, we use the Solar Pro simulation tools to design both flat-plate type and arch type 30kW PV systems. The simulations about arch type PV system applied two ways such as central inverter and string inverter were conducted. The performance ratio (PR) of the PV system with flat-plate type shows the highest value 74[%] when the tilt angle is 30°. In case of arch type, when applying central inverter method, PR value shows approximately 73[%] and no more difference with arch type of the PV array. This value shows 1[%] decrease compare with the flat-plate type. However when applying string inverter methods, the average PR value shows 80 % and 6% improved than the central inverter method.

Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise (고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터)

  • Lee, Sung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

Characteristics of Temperature Control in the Inverter Type Oil Coolers (인버터 타입 오일냉각기의 온도제어 특성에 관한 연구)

  • 이상호;이찬홍;박천홍
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.

Characteristics of New PWM High Frequency Inverter Applied to Induction Heating (유도 가열에 적용되는 새로운 PWM 고주파 인버터의 특성)

  • Ryu, Yeoi-Joung;Lee, Sang-Wook;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • In this paper, the operation principle of a bi-directional switch type resonant AC link snubber circuit was described, together with the practical design procedure, which employs in the proposed power module bridge package type resonant AC link snubber. The novel prototype of power module bridge package type resonant AC link snubber-assisted voltage type sinewave soft switching PWM inverter using IGBT power module was demonstrated herein. It was verified that both the auxiliary power switches in this resonant AC link snubber circuit and the main power switches commutate under the condition of soft switching commutation principle. In addition, the power losses of the new soft switching inverter treated here were analyzed by implementing the experimental data of the IGBT and diode v-i characteristics in addition to switching power loss characteristics into our original computer simulation software developed by the authors. Then, the voltage type sinewave soft switching PWM inverter was high efficiency than that of hard switching PWM inverter, along with performance operation waveforms. In the future, the comparative feasibility study of power module bridge type resonant AC link snubber and its related soft switching inverter in addition to the other types resonant snubber assisted soft switching inverter should be done from a practical point of view.

Design of Low-Pass Type Inverter: UWB Band-Pass Filter with Low Spurious Characteristics

  • Cho, Young-Ho;Choi, Moon-Gyu;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • In this paper, we present the design method for a low-pass type inverter, which can effectively suppress the spurious response associated with band-pass filters. The inverter has a length of ${\lambda}/4$ and employs not only a stepped-impedance configuration but also asymmetrical and bending structures in order to improve frequency selectivity and compactness. The inverter is applied as an impedance/admittance inverter to the ultra-wideband (UWB) band-pass filter. The UWB band-pass filter configuration is based on a stub band-pass filter consisting of quarter-wavelength impedance inverters and shunt short-circuited stubs ${\lambda}/4$ in length. The asymmetrical stepped-impedance low-pass type inverter improves not only the spurious responses, but also the return loss characteristics associated with a UWB band-pass filter, while a compact size is maintained. The UWB band-pass filter using the proposed inverters is fabricated and tested. The measured results show excellent attenuation characteristics at out-band frequencies, which exceed 18 dB up to 39 GHz. The insertion loss within the pass-band (from 3.1 to 10.6 GHz) is below 1.7 dB, the return loss is below 10 dB, and the group delay is below 1 ns.

Design of New Current Full-Bridge Resonant Inverter for Induction Heating System (유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계)

  • Lee, Sang-Hun;Lim, Sang-Kil;Song, Seung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

Driving Method of Direct Type Multi-Lamp Backlight with High Uniformity (고균일도 직하형 백라이트 구동방법)

  • Chun, Young-Tea;Lim, Sung-Kyoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.123-127
    • /
    • 2004
  • Cold cathode fluorescent lamp (CCFL) has been used as a light source for direct type backlights for LCD monitors or TV. One inverter for one CCFL was necessary for maintaining the lamp current so that many inverters were used to drive as many CCFLs of direct type backlight for LCD TV. An inverter for driving 16 CCFLs was developed to reduce the backlight cost. The length and diameter of CCFL were 450mm and 4mm, respectively. Backlight including 16 CCFLs for 26" LCD TV was assembled by using one inverter. The uniformities of the assembled backlight operated by the conventional inverter and the newly developed inverter were 75% and 88%, respectively.

  • PDF