• Title/Summary/Keyword: Inverter switching losses

Search Result 158, Processing Time 0.031 seconds

단상 계통 연계형 풀브릿지 인버터의 스위치 손실 모의 및 분석 (Simulation and Analysis of Losses of Switching Device for Single Grid-connected Full Bridge Inverter)

  • 손명수;임현지;조영훈
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.294-297
    • /
    • 2018
  • This paper analyzes the losses of the switching device for a full bridge inverter connected to the grid. As the development of power conversion system, losses are dominant factors in judging the efficiency of a system. The losses of a switching device can be divided into switching loss and conduction loss, both of which can be estimated by analyzing periodic switching waveform. The switching loss is generated when the switch is turned on and off, while the conduction loss is generated when the switch is turned on. The estimated losses of the MOSFET switch are compared with the simulation results.

Reducing Switching Losses in Indirect Matrix Converter Drives: Discontinuous PWM Method

  • Bak, Yeongsu;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1325-1335
    • /
    • 2018
  • This paper presents a discontinuous pulse width modulation (DPWM) method to reduce switching losses in an indirect matrix converter (IMC) drive. The IMC has a number of power semiconductor switches. In other words, it consists of a rectifier stage and an inverter stage for AC/AC power conversion, which are composed of 12 and 6 switching devices, respectively. Therefore, the switching devices of the IMC suffer from high switching losses in the IMC drives. Various topologies to reduce switching losses have been studied by eliminating a number of switches from the rectifier stage. In this study, in contrast to prior research, a DPWM method is presented to reduce the switching losses of the inverter stage. The effectiveness of the proposed method to reduce switching losses in IMC drives is verified by simulations and experimental results.

3-레벨 T-형 및 NPC 인버터의 전력 손실 비교 분석 (Comparative Analysis of Power Losses for Three-Level T-Type and NPC PWM Inverters)

  • 알레미파얌;이동춘
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.173-183
    • /
    • 2014
  • In this paper, an analysis of power losses for the three-level T-type and neutral-point clamped (NPC) PWM inverters is presented, in which the conduction and switching losses of semiconductor devices of the inverters are taken into account. In the inverter operation, the conduction loss depends on the modulation index (MI) and power factor (PF), whereas the switching loss depends on the switching frequency. Power losses for the T-type and NPC inverters are analyzed and calculated at the different operating points of MI, PF and the switching frequency, in which the four different models of semiconductor devices are adopted. In the case of lower MI, the NPC-type is more efficient than the T-type, and vice versa. The validity of the power loss analysis has been verified by the simulation results.

대전력 교류전동기 구동용 소프트 스위칭 인버터의 EMI 해석 (EMI Analysis of Soft Switching Inverter on High Power AC Motor Drive)

  • 권순걸
    • 융합신호처리학회논문지
    • /
    • 제3권3호
    • /
    • pp.76-81
    • /
    • 2002
  • 대전력 전동기 구동장시스템에서 하드 스위칭 토폴로지는 심각한 스위칭 손실과 EMI잡음문제를 일으키며, 인버터 스위칭 주파수는 과도한 손실과 열적문제 때문에 제한되게 된다. 본 연구의 목적은 개선된 소프트 스위칭 토폴로지에 의해 스위칭손실과 EMI를 저감할 수 있는 대용량 교류전동기의 구동에 적합한 시스템을 개발하고자하며, 시뮬레이션과 실험을 통하여 그 타당성을 입증하였다.

  • PDF

단상 계통 연계형 풀브릿지 인버터의 스위치 손실 모의 및 분석 (Simulation and Analysis of Losses of Switching Device for Single Grid-connected Full bridge inverter)

  • 손명수;임현지;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.101-102
    • /
    • 2017
  • This paper presents analysis of losses of switching device for full bridge inverter connected to grid. The losses are a dominant factor that judges efficiency of the system. The losses of switching device are divided to switching loss and conduction loss. They are can be estimated by analyzing periodic switching waveforms. The switching loss is generated at the point that turn-on and off. And the conduction loss is generated while the switch is on condition. The estimated losses of switch are compared to simulation result in this paper.

  • PDF

A Hybrid Modulation Strategy with Reduced Switching Losses and Neutral Point Potential Balance for Three-Level NPC Inverter

  • Jiang, Weidong;Gao, Yan;Wang, Jinping;Wang, Lei
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.738-750
    • /
    • 2017
  • In this paper, carrier-based pulse width modulation (CBPWM), space vector PWM (SVPWM) and reduced switching losses PWM (RSLPWM) for the three-level neutral point clamped (NPC) inverter are introduced. In the case of the neutral point (NP) potential (NPP) offset, an asymmetric disposition PWM (ASPDPWM) strategy is proposed, which can output PWM sequences correctly and suppress the lower order harmonics of the inverter effectively. An NPP balance strategy based on carrier based PWM (CBPWM) is analyzed. A hybrid modulation strategy combining RSLPWM and the NPP balance based on CBPWM is proposed, and hysteresis control is adopted to switch between the two modulation strategies. An experimental prototype of the three-level NPC inverter is built. The effectiveness of the hybrid modulation is verified with a resistance-inductance load and a permanent magnetic synchronous motor (PMSM) load, respectively. The experimental results show that reduced switching losses and an acceptable NPP can be effectively achieved in the hybrid modulation strategy.

Power Module Bridge Type Auxiliary Resonant AC Link Snubber-Assisted Three-Phase Soft Switching Inverter

  • Hisashi Iyomori;Nagai, Shin-ichiro;Masanobu Yoshida;Eiji Hiraki;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.77-86
    • /
    • 2004
  • This paper presents a novel three-phase power module bridge type auxiliary resonant AC link snubber for the three-phase voltage-fed sinwave soft switching PWM inverter operating under specific instantaneous space voltage vector modulation. The operating principle of this resonant snubber is described for current source load model during one switching period, along with its design approach based on the simulation data. The performance evaluations of space vector modulation three-phase sinewave soft switching inverter with a new three-phase active auxiliary resonant AC link snubber are discussed as compared with those of three-phase voltage source-fed sinewave hard switching PWM inverter with a standard space voltage vector modulation strategy. The power loss analysis and conventional efficiency estimation of three-phase soft switching PWM inverter using ICBT modules are carried out including all the conduction power losses based upon the measured v-i characteristics of IGBT and its antiparallel diode as well as their switching losses.

스위칭 손실 저감을 위한 이단 PWM 인버터 (PWM Inverter For Reducing Switching Loss)

  • 최봉주;정진범;김희준;백수현;이주;안강순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.207-209
    • /
    • 2004
  • The conventional pulse width modulation dc to at inverters have a defect that all power devices are switched at high switching frequency. Therefore switching losses are significant. This paper proposed a dual-stage inverter that full bridge switches are operating at low output frequency while a high switching frequency are performed by a pre-inverter switch. The proposed inverter is shown to have small switching losses. Simulation and experiments are performed for verification.

  • PDF

전압원 인버터의 모델 예측 제어에서 스위칭 손실을 줄이기 위한 최적의 제로 벡터 선택 방법 (Optimal Zero Vector Selecting Method to Reduce Switching Loss on Model Predictive Control of VSI)

  • 박준철;박찬배;백제훈;곽상신
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-279
    • /
    • 2015
  • A zero vector selection method to reduce switching losses for model predictive control (MPC) of voltage source inverter is proposed. A conventional MPC of voltage source inverter has not been proposed, and a method to select the redundancy of the zero vector is required for this study. In this paper, the redundancy of the zero vectors is selected with generating a zero sequence voltage to reduce switching losses. The zero vector of 2-level inverter is determined by determining sign of the zero sequence voltage. In the proposed method, the quality of the current is retained and switching loss can be reduced compared with the conventional method. This result was verified by P-sim simulation and experiments.

Hybrid Cascaded MLI topology using Ternary Voltage Progression Technique with Multicarrier Strategy

  • Venugopal, Jamuna;Subarnan, Gayathri Monicka
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1610-1620
    • /
    • 2015
  • A major problem in conventional multilevel inverter is that an increase in power semiconductor switches causes an increase in cost and switching losses of the inverter. The multicarrier strategy adopted for the multilevel inverters has become more popular due to reduced cost, lower harmonic distortion, and higher voltage capability than the conventional switching strategy applied to inverters. Various topologies and modulation strategies have been reported for utility and drive applications. Level shifted based pulse width modulation techniques are proposed to investigate the performance of the multilevel inverter. The proposed work focuses on reducing the utilized switches so that the cost and the switching losses of the inverter do not go up and the consistent efficiency could be achieved. This paper presents the detailed analysis of these topologies. The analysis is based on the number of switches, DC sources, output level, maximum voltage, and the efficiency. As an illustration, single phase cascaded multilevel inverter topologies are simulated using MATLAB/SIMULINK and the experimental results demonstrate the viability of these inverters.