• 제목/요약/키워드: Inverter speed control

검색결과 619건 처리시간 0.026초

4-레벨 인버터의 DC-링크 전압 균형을 위한 향상된 전압 제어 기법 (An Improved Voltage Control Scheme for DC-Link Voltage Balancing in a Four-Level Inverter)

  • 김래영;이요한;최창호;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.544-554
    • /
    • 1999
  • Multi-level inverters are now receiving widespread interest form the industrial drives for high power variable speed applications. Especially, for the high power variable speed applications, a diode clamped multi-level inverter has been widely used. However, it has the inherent problem that the voltage of the link capacitors fluctuates. This paper describes a voltage control scheme effectively to suppress the DC-link potential fluctuation for a diode clamped four-level inverter. The current to flow from/into the each link capacitor is analyzed and the operation limit is obtained when a conventional SVPWM is used. To overcome the operation limit, a modified carrier-based SVPWM is proposed. Various simulation and experiment results are presented to verify the proposed voltage control scheme for DC-link voltage balancing.

  • PDF

IPM 스위칭 소자를 적용한 AC 전동차 추진제어장치 (Converter/Inverter) 개발 (Development of AC Electric Vehicle Propulsion System (Converter/Inverter) using IPM Switching Device)

  • 노애숙;김태윤
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.233-240
    • /
    • 2005
  • 본 논문은 현재까지 전적으로 수입에 의존하던 국내 교류 전동차용 추진제어장치(Converter/Inverter)를 대용량 IPM 스위칭 소자를 적용하여 개발된 시스템을 제안한다. 컨버터의 용량을 향상시키기 위해 2대의 PWM 컨버터를 병렬 운전하고 병렬 운전 시 각각의 컨버터 스위칭 각을 다르게 제어하여 고조파 함유를 줄였으며 DC-Link 단의 Beatless 제어를 수행하였다. VVVF 인버터 제어의 경우, 저속의 운전영역에서는 순시 토크 제어가 가능한 백터제어를 적용하고, 고속 운전 영역에서는 슬립 주파수제어를 적용하는 백터 제어와 스칼라 제어의 병용 제어기법을 제시하였다. 제시된 추진제어장치는 4대의 210kW 유도전동기를 이용하여 철도차량용 추진제어장치에 적용되는 관련 규격의 각종 시험을 통해 그 성능을 검증하였다.

부트스트랩 회로를 적용한 3-레벨 NPC 인버터의 저속 운전을 위한 PWM 스위칭 전략 (A PWM Control Strategy for Low-speed Operation of Three-level NPC Inverter based on Bootstrap Gate Drive Circuit)

  • 정준형;구현근;임원상;김욱;김장목
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.376-382
    • /
    • 2014
  • This paper proposes the pulse width modulation (PWM) control strategy for low-speed operation in the three-level neutral-point-clamped (NPC) inverters based on the bootstrap gate drive circuit. As a purpose of the cost reduction, several papers have paid attention to the bootstrap circuit applied to the three-level NPC inverter. However, the bootstrap gate driver IC cannot generate the gate signal to the IGBT for low-speed operation, because the bootstrap capacitor voltage decreases under the threshold level. For low-speed operation, the dipolar and partial-dipolar modulations can be the effective solution. However, these modulations have drawbacks in terms of the switching loss and THD. Therefore, this paper proposes the PWM control strategy to operate the inverter at low-speed and to minimize the switching loss and harmonics. The experimental results are presented to verify the validity on the proposed method.

전브리지 공진형 인버터에 의한 단상 유도전동기의 디지탈제어에 관한 연구(I) -저주파수에서 전브리지 공진형 이버터의 전류특성에 대하여- (A Study on the Digital Control of Single Phase Induction Motor Driven by the Full Bridge Resonant Inverter(I) - The Current Characteristics of Full - bridge Resonant Inverter at Low Frequency -)

  • 노영오;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.70-79
    • /
    • 1993
  • The application of A.C. motor to servo system is rapidly increased according to the recent advance of power electronics and digital control techniques. The induction motor which has a simple structure and needs less maintenance is used in the industrial field for the variable speed and position control recently. In this paper, the current characteristic of the full-bridge resonant inverter is studied by comparing with the computer simulation and the laboratory experiment when the ratio of forced frequency to the natural frequency and the ratio of conduction time to the period at the given frequency is changed. And then, the full-bridge resonant inverter is applied to the speed control of single phase induction motor.

  • PDF

VHDL을 이용한 유도전동기의 직접 토크 제어 ASIC 설계 (ASIG Design for Direct Torque Control of Induction Motor using VHDL)

  • 이호재;김세진;이병춘;권영안
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.336-338
    • /
    • 2000
  • Recently many studies have been performed for variable speed control of induction motor. Direct Torque Control(DTC) is emerging technique for variable speed control of PWM inverter driven induction motor. DTC allows the direct control of stator flux and instantaneous torque through simple algorithm. In this paper ASIC design technique using VHDL is applied to DTC based speed control of induction motor. ASIC for DTC based speed control is designed through the description of coordinate transformation, speed controller stator flux and torque estimator, stator flux and torque controller, stator flux position detector. FSM(Finite State Machine) and inverter voltage switching vector. Finally the above system has been implemented on the FPGA (XC4052XL-PG411). Simulation and experiment has been performed to verify the performance of the designed ASTC.

  • PDF

Regular-sampled PWM 방법(方法)에 의한 영구자석(永久磁石) 동기(同期) 전동기(電動機)의 자기(自己) 제어(制御) 시스템 (Self Control System for Permanent Magnet Synchronous Motor Drives Using Regular-Sampled PWM Method)

  • 윤병도;김윤호;김일환;김명용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.319-322
    • /
    • 1990
  • Self-controlled permanent magnet synchronous motor (PMSM) has similar operating characteristics as seperately excited dc motor. It is favored in servo applications due to its improvement of efficiency and maintenance. This paper presents completely digitalized controller using microprocessor and voltage fed inverter. The speed control system for PMSM is implemented. To control the motor speed, the control system regulates the magnitude of Inverter output voltage by regular-sampled PWM method to generate sinusoidal PWM wave with microprocessor. And to keep the range of inverter switching frequency, it varies the number of pulse train according to the speed.

  • PDF

PWAM 방식을 이용한 공조시스템용 인버터의 THD 저감 방법 (PWAM Based THD Reduction of Inverter for Air-Conditioning Blower)

  • 임승범;이윤하;전찬용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.97-98
    • /
    • 2011
  • The HVAC(Heating Ventilation and Air conditioning) system is controlled by two ways, one is ON/OFF control and the other is PWM inverter with V/F. Control of blower with the use of PWM inverter has quite some benefits such as the capability of changing speed, high efficiency and reduced noise level compared with ON/OFF control. But if blower is operated at low speed, high THD generated by decrease of ma, and output voltage lowered in proportion to frequency. To solve these problems, filter should be installed at the output stage of inverter, which can decrease THD but has problems such as increase of volume size and additional braking resistance. This paper proposes the PWAM method which can reduce THD instead of installing the filter at the output stage of inverter. The proposed PWAM method is an inverter modulation method that fixes the modulation index of inverter to reduce THD by varying DC link voltage of inverter unlike conventional PWM method. Finally, the validity of proposed PWAM methods verified by experiments.

  • PDF

인버터의 비선형 특성이 유도전동기의 자속 추정에 미치는 영향에 대한 연구 (A study on the effect of inverter nonlinear characteristic on the flux estimation of an induction motor)

  • 김상훈;김태석
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.167-174
    • /
    • 2008
  • In this paper, the analysis on type effect of inverter output voltage distortion on the control of an induction motor is discussed. The inverter output voltage is distorted differently from the reference voltage owing to the inverter nonlinear characteristic. The inverter nonlinear characteristic results from the voltage drop, the inherent characteristic of the power semiconductor, and the dead time for preventing the short circuit of the inverter leg. This characteristic distorts the inverter output voltage and then, causes the motor flux estimation error. Although this characteristics do not significantly effect in the general-purpose induction motor control, but significantly effect on the low-speed operation of high performance motor control such as the sensorless vector control.

  • PDF

Resonance Suppression using Sensorless Control of Dual SPMSMs Fed by Single Inverter

  • Eom, Jae-Boo;Choi, Jong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2376-2384
    • /
    • 2018
  • To reduce the size and cost of motor driving systems, several methods for driving multiple parallel-connected motors with a single inverter have been proposed. However, dual PMSMs driven by a single inverter, unlike induction motors, have a problem with instability due to system resonance caused by disturbances such as load imbalance and tolerances between two motors. To drive dual SPMSMs fed by a single inverter, this paper proposes an active damping algorithm to effectively suppress resonance by using one-sided sensorless speed control and position difference estimation. By deriving rotor position difference from d-q current differences between two motors, the proposed method is affected less by position difference estimation errors and is simpler than dual sensorless position estimation.

가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계 (A Fuzzy Logic Controller Design for Maximum Power Extraction of Variable Speed Wind Energy Conversion System)

  • 김재곤;허욱열;김병륜
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.753-759
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.