• 제목/요약/키워드: Inverter driving system

검색결과 168건 처리시간 0.021초

전기자동차 구동시스템 설계 (Design of Drive System for Electric Vehicle)

  • 오진석
    • 한국정보통신학회논문지
    • /
    • 제3권2호
    • /
    • pp.465-470
    • /
    • 1999
  • This paper presents a design method of driving system for EV(Electric Vehicle). EV driving system consist of batteries, battery interface system and inverter. The power control circuit of the driving system is simple, since only one PWM(Pulse Width Modulation) inverter is used. These test spectrums and waveforms can be used to determine the filter component ratings as well as to compute the harmonics injected into the source. The hybrid control strategy which can reduced harmonic components. The analysis results indicate that the required capacity of the condenser can be reduced with LC filter. In this paper, the design and implementation of the proposed systems are described and some experimental results are given to show the performance of this driving system. The control strategy of the system to available inverter's power and motor's power and torque is discussed.

  • PDF

공진형 인버터를 사용한 적층액츄에이터형 초음파 노즐 구동시스템의 전기적 특성 (Electrical Properties of Multilayer Actuator Structured-ultrasonic Nozzle Driving System using a Resonant Inverter)

  • 황락훈;김화수;김국진;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제20권11호
    • /
    • pp.953-958
    • /
    • 2007
  • In this paper, multilayer actuator structured-ultrasonic nozzle and resonant inverter driving circuit were manufactured, respectively. Its electrical properties were investigated. Multilayer actuator structured ultrasonic nozzle was fabricated using PMN-PNN-PZT ceramics showing excellent piezoelectric characteristics. In order to drive ultrasonic nozzle, resonant PWM inverter was used. The purpose of this study is to find the optimal driving condition of ultrasonic nozzle. Accordingly, electrical and temperature characteristic of multilayer ultrasonic driving system were investigated by experiments as a function of the series resonance inductance. The driving current of ultrasonic nozzle showed the maximum current of 27 mA. Also, the surface temperature of ceramic vibrator showed $44^{\circ}C$ at driving time for 20 min. The ultrasonic nozzle was stably operated in the case of driving for more than 20 min.

단상 유도 전동기를 위한 하프브리지 인버터 (Half Bridge Inverter for Single Phase Induction Motor Driving)

  • 이종규;김영삼;원영진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.181-183
    • /
    • 1999
  • This paper is about the design of half-bridge inverter controller with low cost and simple configuration for low power single-phase induction motor driving. The simple controller is composed of MCU and PLD. Also, to limit the overcurrent at initial driving, auxiliary function is added, and stabilizes the system. In order to verify the performance of the proposed methode, we design 500W inverter system, and in result, the response time of the proposed method compared with line voltage driving method is reduced by 200[msec].

  • PDF

인버터구동 고압전동기 열화특성 분석 및 필터 설계기법 확립 (Insulation System and Filter Design for Inverter-Fed Motor)

  • 최영찬;이상동;김익모;정명길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.711-713
    • /
    • 2000
  • Recently, the insulation breakdown accident happened at 6.6kV inverter driving motor brings out the reliability decrease to the motor driving system. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the insulation system of motor which is driven by inverter. The circuit parameters of cable are calculated by EMTP(Electromagnetic Transient Program) to simulate the system. And we use MATLAB to find the appropriate filter parameter. The simulation and the test results are compared to verify the suitability of the filter parameter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of insulation breakdown accidents. The endurance test scheme and the configuration method of insulation system are established.

  • PDF

마이크로 프로세서에 의한 델타인버어터 구동 유도전동기의 운전특성에 관한 연구 (A Study on the Driving Characteristics of Delta Inverter Driving Induction Motor Control System Based on the Microprocessor)

  • 윤병도;이승한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.527-529
    • /
    • 1987
  • This paper presents a study on the driving characteristics or delta inverter driving induction motor control systems based on the microprocessor. Delta inverter is a novel circuit which uses only three power transistor. Requiring approximately hair the components or a conventional bridge inverter it therefore has a merit of coat and Simplicity. The basic operating principles of the delta inverter and conventional bridge inverter are argued, using resistive and inductive load. Sinusoidal PWM method uses to reduce the harmonic components of its output waveform to acceptable levels.

  • PDF

DEVELOPMENT OF INVERTER AND POWER CAPACITORS FOR MILD HYBRID VEHICLE (MHV) - TOYOTA "CROWN"

  • Shida, Y.;Kanda, M.;Ohta, K.;Furuta, S.;Ishii, J.
    • International Journal of Automotive Technology
    • /
    • 제4권1호
    • /
    • pp.41-45
    • /
    • 2003
  • The 42V Mild Hybrid System has been released into market by Toyota for the first time in the world in 2001. The set-up employs an inverter unit to control the motor/generator (MG) electronically. The driving system called such as Toyota Mild Hybrid System (TMHS) has additional new functions to conventional internal combustion engines. When stopping vehicle, the engine stops promptly. When starting vehicle, by releasing the brake pedal MG starts the vehicle at the same time (EV-driving mode). When stepping on the accelerator pedal, or after a given period of time the engine firing occurs and the engine-driving mode starts. When running by motor, the power is supplied to the motor from 36V battery through the inverter. High outputs and instant responses are required for Inverter. At the same time, the compact volume is required to fit into the limited space of the engine room. The compact size and high output are also required to Power Capacitor used for this inverter. The power capacitors has been newly developed, shaped in "flat" type, suitably for the inverter. The points of developments on inverter and power capacitor are described in this paper.his paper.

인버터 구동에 따른 고압전동기 사고사례와 대책 (Failure Case-Study and Countermeasures of High-Voltage Motor with Inverter Drive System)

  • 최영찬;우명호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2002
  • Recently, the insulation breakdown accident has been experienced at 6.6kV inverter driving motor. That brought about the reliability degradation of motor driving system.. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the Insulation system of motor which Is driven by inverter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of Insulation breakdown accidents.

  • PDF

3개의 양방향 벅-부스트 컨버터를 이용한 3상 인버터 시스템 (Three Phase Inverter System Utilizing Three Bi-directional Buck-Boost Converter)

  • 김성영;남광희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.551-554
    • /
    • 2006
  • An inverter system which consists of three bi-directional buck-boost converters, is proposed for motor driving. Three phase sinusoidal output voltages can be generated by utilizing three buck-boost converters. The advantage of this scheme is that it does not require a separate DC-DC converter for motor driving, i.e. inverter function is combined into the three DC-DC converters. This topology is suitable for inverters for hybrid or fuel cell vehicles where DC link voltage is subject to change depending upon charging status or output power. So the proposed system is capable of driving motor at high speed. The converter system is controlled by PI controller and simulation results done by MATLAB SIMULINK are provided.Ҙ?⨀ሉȀ̀㘰々K䍄乍?ጊ츀Ѐ㔹〻Ԁ䭃䑎䴀

  • PDF

인휠 모터 구동용 인버터의 냉각구조에 대한 해석적 평가 (Analytical Assessment on the Cooling Structure of In-wheel Driving Inverter)

  • 김성철
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.1-6
    • /
    • 2014
  • In-wheel driving inverter inside engine room sometimes operates in the harsh environment like high temperature of about $105^{\circ}C$. Especially, the size and power density of the inverter has become smaller and more increased. Thus, it is essential to manage the temperature of the inverter with IGBT (Insulated Gate Bipolar Transistor) switching devices for performance and endurance, because the temperature can be getting increase. In this paper, we performed the thermal flow analysis of inverter models with wave type and pin fin type cooling channels, and investigated the heat transfer characteristics of the inverter models using cooling water on channels at 8 L/min and $65^{\circ}C$. Also, we compared the thermal performance under various conditions such as coolant flow rate and layered power module structure. Therefore, we determined the feasibility of the initial inverter models and the thermal performance enhancement.

외부전극 형광램프 구동용 인버터 설계 및 제작 (Design and manufacture of Inverter for Driving Electrode Fluorescent Lamp)

  • 윤동한
    • 한국정보전자통신기술학회논문지
    • /
    • 제6권2호
    • /
    • pp.76-80
    • /
    • 2013
  • 본 논문에서는 LCD 백라이트용 외부전극 형광램프를 구동하기 위한 인버터를 설계하였다. 시스템을 AC 입력으로부터 램프를 구동하는 인버터까지의 과정을 2단 시스템으로 구성하면 기존의 시스템 보다 전력의 효율을 높일 수 있을 뿐만 아니라 부피나 무게의 감소, 나아가 저가격화에도 유리하다. EEFL를 구동하기 위해서 AC입력 전원을 안정적이고 역률을 높이며 AC 85V~265V에서 사용할 수 있도록 PFC Block과 EEFL를 구동하기 위한 Inverter Block으로 구성하였다.