• Title/Summary/Keyword: Inverter driven

Search Result 289, Processing Time 0.028 seconds

Analysis of Inverter-Fed Induction Motor Using F.E.M and Harmonic Equivalent Circuit (슬롯피치 경계 조건을 이용한 인버터 구동 유도 전동기의 회전자 등가회로 정수 추출 및 특성해석)

  • Lee, Geon-Ho;Kim, Byeong-Tae;Gwon, Byeong-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.331-338
    • /
    • 2002
  • An inverter-fed induction is driven by a harmonic voltage source so that it is necessary to be analysed by time-stepping F.E.M. But it takes so long time that disadvantageous to design. This paper presents a simple analysis method for inverter-fed induction motor using FEM and harmonic equivalent circuit. First, the rotor bar resistance and the leakage reactance are determinated by FEA for 1 slot region in rotor to consider the skin effect and the saturation. Secondly, the characteristic of the motor is analyzed by the harmonic equivalent circuits consisting of the obtained parameters from the FEA. This method is carried out to analyze an induction motor driven by the sinusoidal voltage and the inverter. The results are verified by comparing with those of the time-step F.E.A and the experiment.

A Study on commercial frequency source with ZCS type high frequency resonant Inverter

  • Kim, Jong-hae;Kim, Dong-Hee;Bae, Sang-Jun
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1030-1035
    • /
    • 1998
  • This paper describes a new dc-ac inverter system, which for achieving sinusoidal ac waveform make use of parallel loaded frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. Since current through switches is always zero at its turn-on in proposed inverter, low stress and low switching loss is achieved. The theoretical analysis is proved through the experimental test.

  • PDF

Analytical Study of Single Phase Reluctance Motor Driven by SCR Inverter (SCR 인버어터로 구도오디는 단상 Reluctance Motor의 특성에 관한 연구)

  • Jong Swoo Won
    • 전기의세계
    • /
    • v.22 no.2
    • /
    • pp.33-39
    • /
    • 1973
  • This paper presents numerical analysis by omputer for the steady state characteristics of the single phase reluctance motor driven by the bridge type SCR inverter and also the experiments were carried out to verify the numerical analysis data for the current, voltage, and torque of the motor. It shows that the inductance of the inverter, the capacity of the commutation condenser and the frequency of the inverter have great effects to the magnitude and wave form of the motor terminal voltage and current. It is clear that the capacity of the commutation condenser and the inductance of the inverter circuit have to be adequately selected in order to stabilize the motor operation.

  • PDF

Inverter Losses Reduction for Rectangular Drive BLDCM using Synchronous Rectification (구형파 구동 BLDCM의 동기정류를 사용한 인버터 손실 저감)

  • Nam, Myung-Joon;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.117-125
    • /
    • 2016
  • In this paper, the inverter switch losses of BLDC motor for three types of PWM methods and power devices were analyzed. When the BLDC motor is driven at low currents, the inverter switch losses for MOSFET are low because MOSFET operates like resistance. However, the inverter switch losses for IGBT are higher than MOSFET due to its large turn-off losses. Moreover, synchronous rectification switching method is adaptable because MOSFET has 2-channel. So, MOSFET can be driven with more low impedance and losses. For low power inverter with MOSFET, the power losses of unified PWM are lower than that of unipolar and bipolar PWM. Proposed method and losses analysis results are verified by examination and simulation using Matlab/Simulink.

Superheat Control of an Inverter-driven Heat Pump Using PI Control Algorithm

  • Park, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.106-115
    • /
    • 2002
  • The performance of an inverter-driven water-to-water heat pump with an electronic expansion valve (EEV) was measured as a function of compressor frequency, load conditions, and EEV opening. Based on the test results, a controller using proportional integral (PI) feedback or PI feedforward algorithm was designed and tested to investigate capacity modulation and transient response control of the system. Although the relation between superheat and EEV opening of the heat pump showed nonlinear characteristics, a control gain obtained at the rated frequency was applicable to various operating conditions without causing large deviations. When the simple PI feedback control algorithm was applied, a large overshoot of superheat and wet compression were observed due to time delay effects of compressor frequency. However, applying PI feedforward control scheme yielded better system performance and higher reliability, compared to the PI feedback algorithm.

Experimental Study on the Performance Characteristics of an Injection Type Scroll Compressor (인젝션용 스크롤 압축기의 성능특성에 관한 실험적 연구)

  • Cho, Hong-Hyun;Kim, Yong-Chan
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.193-198
    • /
    • 2000
  • For an inverter-driven compressor, the discharge temperature increased with a rise of frequency, Therefore, it is necessary to control the discharge temperature at high frequencies in order to obtain system reliability and efficiency. This paper describes the effects of liquid injection system on the performance of an inverter-driven scroll compressor. Experiments were performed at ASHRAE-T conditions. Frequency was altered from 45 to 105Hz. As results of the present work, the refrigerant discharge temperature fur the injection system was dropped approximately $10{\sim}20^{\circ}C$ as compared to those for the non-injection system. The COP of the compressor was improved approximately $0.8{\sim}9.3%$ at high frequencies(75, 90, and 105 Hz).

  • PDF

A Study on the Reduction of Computation Time in Finite Element Analysis of Electric Machines Driven by PWM Inverters (PWM 인버터로 구동되는 전기기기의 유한요소 해석시 계산시간 저감방법에 관한 연구)

  • Jung, In-Soung;Hyun, Dong-Sack
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.226-228
    • /
    • 1999
  • This paper presents an efficient analysis method using time-stepping finite element method for electric machines driven by pulse width modulation (PWM) inverter. In the method, the value of time-step is changed according to the PWM logic of inverter, and the calculation time can be reduced while maintaining analysis accuracy. Using the method, the dynamic characteristics of a permanent magnet linear synchronous motor (PMLSM) driven by PWM inverter are analyzed.

  • PDF

The Harmonic Loss Analysis for Inverter Driven Large Induction Motor (대용량 인버터 구동 전동기 고조파 손실해석)

  • Lee, J.L.;Park, J.T.;Kwon, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1047-1048
    • /
    • 2007
  • In this paper, the harmonic loss of the inverter driven induction motor was analyzed. It was analyzed through the theoretical consideration on the variations of equivalent circuit constants, and harmonic losses, including the effects of resistance increase and inductance decrease of stator, not through the general method that considering just the effects of the harmonic losses of only the rotor. It was verified by comparing the harmonic analysis results with the test results for HHI's inverter driven motor.

  • PDF

Space-vector PWM Techniques for a Two-Phase Permanent Magnet Synchronous Motor Considering a Reduction in Switching Losses

  • Lin, Hai;Zhao, Fei;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.905-915
    • /
    • 2015
  • Two PWM techniques using space vector pulse-width modulation (SVPWM) are proposed for a two-phase permanent magnet synchronous motor (PMSM) driven by a two-phase eight-switch inverter. A two-phase motor with two symmetric stator windings is usually driven by a two-phase four-, six-, or eight-switch inverter. Compared with a four- and six-switch inverter, a two-phase eight-switch inverter can achieve larger power output. For two-phase motor drives, the SVPWM technique achieves more efficient DC bus voltage utilization and less harmonic distortion of the output voltage. For a two-phase PMSM fed by a two-phase eight-switch inverter under a normal SVPWM scheme, each of the eight PWM trigger signals for the inverter have to be changed twice in a cycle, causing a higher PWM frequency. Based on the normal SVPWM scheme, two effective SVPWM schemes are investigated in order to reduce the PWM frequency by rearranging four comparison values, while achieving the same function as the normal PWM scheme. A detailed explanation of the normal and two proposed SVPWM schemes is illustrated in the paper. The experimental results demonstrate that the proposed schemes achieve a better steady performance with lower switching losses compared with the normal scheme.

Development of Traction Unit for 2-motor Driven Electric Vehicle

  • Park, Jung-Woo;Koo, Dae-Hyun;Kim, Jong-Moo;Kim, Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.950-954
    • /
    • 1998
  • This paper describes a development of traction unit for 2-motor driven electric vehicle (EV). The traction unit is consisted with an interior permanent magnet synchronous motor (IPMSM), a reduction gear and an inverter for electric vehicle that is driven by 2 motors without differential gear. For traction unit, prototype IPMSM and inverter have been developed. The IPMSM was designed by CAD program that was developed with both equivalent circuit method and FEM. Also the inverter was developed to drive 2 motors with 6 legs IGBT switches in a control board. The vector control algorithm was implemented with maximum torque control method in the constant torque region and field weakening control method in the constant power region considering inverter capacity. To verify that the traction unit is more high efficiency and has more high power density than a traction unit with induction motor with the same power, we would like to show the results about the design and analysis of the IPMSM and the experiment results about the traction unit.

  • PDF