• 제목/요약/키워드: Inverter built-in

검색결과 107건 처리시간 0.023초

불균등 임피던스 선로를 갖는 인버터기반 분산전원의 부하전압 불평형을 보상하는 드룹 제어 (Droop Control to Compensate Load Voltage Unbalance for Inverter-based Distributed Generations with Unequal Impedance Lines)

  • 양원모;김현준;한병문
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1193-1203
    • /
    • 2016
  • This paper proposes a droop control scheme to compensate the unbalanced line-to-line voltage of unbalanced 3-phase load which is coupled with two inverter-based distributed generations through unequal impedance lines. Unbalanced line-to-line load voltages occur due to using single-phase loads, which brings about bad effects on the coupled inverters and the distributed generations. In order to compensate the unbalanced line-to-line voltages, a positive sequence voltage control was used for sharing the active and reactive power and a negative sequence control was used for reducing the negative sequence voltage. The feasibility of the proposed scheme was first verified by computer simulations, and then experiments with a hardware set-up built in the lab. The experimental results were compared with the simulation results to confirm the feasibility of the proposed scheme.

BID-IPM 개발에 관한 연구 (A study on the development of BID-IPM)

  • 오필경;연재을;김희준;박민희;안성윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.158-161
    • /
    • 2005
  • For low power motor control, there are increasing demands for compactness, cost effective and built in many functions. Hence Intelligent Power Module(IPM) is considered as an important technology in inverter-driven motor applications. Regarding BID-IPM(Built In DC/DC converter, Intelligent Power Module) newly developed to integrate NPT-IGBT, HVIC and Flyback converter in a compact package, this paper discussed design of BID-IPM and presented the experimental results by using signal source board and equivalent load test board.

  • PDF

A Current-Fed Parallel Resonant Push-Pull Inverter with a New Cascaded Coil Flux Control for Induction Heating Applications

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi;Milimonfare, Jafar
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents a cascaded coil flux control based on a Current Source Parallel Resonant Push-Pull Inverter (CSPRPI) for Induction Heating (IH) applications. The most important problems associated with current source parallel resonant inverters are start-up problems and the variable response of IH systems under load variations. This paper proposes a simple cascaded control method to increase an IH system's robustness to load variations. The proposed IH has been analyzed in both the steady state and the transient state. Based on this method, the resonant frequency is tracked using Phase Locked Loop (PLL) circuits using a Multiplier Phase Detector (MPD) to achieve ZVS under the transient condition. A laboratory prototype was built with an operating frequency of 57-59 kHz and a rated power of 300 W. Simulation and experimental results verify the validity of the proposed power control method and the PLL dynamics.

Power HILS를 활용한 IEEE 1547-2018 기반 스마트 인버터의 기술개발 및 형식시험 연구 (Application Development and Type Test for Smart Inverter Based on IEEE 1547-2018 Utilizing Power HILS)

  • 신단비;강모세;이현아;홍선리;윤기환;백종복
    • 전기전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2022
  • 전력시스템의 신뢰성을 보장하며 분산전원의 수용성을 높이기 위해 IEEE 1547과 같은 표준을 개정하여 분산전원의 계통 연계기준을 강화하고 있다. 본 논문은 이러한 표준을 준수하는 IEEE 1547-2018 기반의 스마트 인버터 기능의 제어 알고리즘을 제안하고, 스마트 인버터 기술의 검증을 위해 구축한 Power HILS 기반의 테스트 플랫폼을 소개한다. 스마트 인버터 기능 중 Volt-var 제어와 Frequency-watt 제어 알고리즘은 상호운용성 표준을 준수하도록 해당 기능의 curve를 상위로부터 설정할 수 있도록 하며, 각 기능의 Enable 신호 시점을 상위 지령에 따라 제어할 수 있도록 하였다. 표준에 따라 Power HILS 테스트 플랫폼을 통해 Volt-var 제어와 Frequency-watt 제어에 대한 형식시험을 수행하였고, 명시된 표준 형식시험을 전부 만족함을 측정 결과를 통해 검증하였다.

6kW급 모터 드라이브 시스템을 위한 새로운 1200V SPM 개발 (Development of New 1200V SPM® Smart Power Module for up to 6kW Motor Drive Applications)

  • 박상민;이강윤;홍승현;고재성;권태성;용성일
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.485-486
    • /
    • 2015
  • This paper introduces the new 1200V $SPM^{(R)}$ (Smart Power Module), which is fully optimized and intelligent integrated IGBT inverter modules for up to 6kW motor drive applications. It utilizes newly developed NPT trench IGBT with the advanced STEALTHTM freewheeling diode, and built-in bootstrap diode. HVICs, multi-function LVIC, and built-in thermistor provide good reliable characteristics for the entire system. This module also takes technical advantage of DBC(Direct Bonded Copper) substrate for the better thermal performance. This paper provides an overall description of the newly developed 1200V/35A $SPM^{(R)}$ 2 product.

  • PDF

FCATS Device를 이용한 송전전력 제어 (Transmission Power Control using FACTS Device)

  • 박승호;김영조;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.152-154
    • /
    • 2006
  • This paper presents an electric power control scheme in the transmission line using a UPFC(Unified Power Flow Controller). From the practical application viewpoint, the simultaneous realization of the power response desired. The author propose a new power control algorithm for UPFC. To verify the effectiveness of the proposed algorithm, a protype inverter is built and some experiments are carried out.

  • PDF

고장진단을 위한 영구자식 동기전동기의 권선 단락에 의한 고장모델 연구 및 특성해석 (A Study on Stator Winding Turn-Fault Model for Fault Diagnosis in Inverter-Driven Permanent Magnet Moor Drives)

  • 김경화;최동욱;구본관;정인성
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.18-28
    • /
    • 2009
  • 고정자 권선의 단락으로 인한 고장을 해석하고 진단 알고리즘의 효과적인 시험 평가를 위해 사용될 수 있는 인버터 구동 영구자석 동기전동기의 고장모델이 제시된다. 기존에 전동기의 해석과 제어에 많이 사용되는 dq 모델은 상전압 모델을 변환한 것으로 전동기 고정자의 권선 단락 시에는 더 이상 3상평형 조건이 성립하지 않기 때문에 인버터 극전압으로부터 전동기 입력 전압을 구하기가 쉽지 않아 고장모델의 해석을 위해서 사용하기 어렵다. 이를 해결하기 위해 전동기 3상 변수와 선전압 관계식을 이용한 전동기의 고장모델이 제안된다. 제안된 고장모델의 타당성을 입증하기 위해 시뮬레이션이 수행되며 내부 고정자의 권선 단락이 가능하도록 제작된 전동기와 DSP TMS320F28335를 이용한 제어 시스템에 의해 동일 고장 조건에서 비교 실험이 수행된다.

On-line 테스팅을 위한 새로운 내장형 전류 감지 회로의 설계 (Design of New Built-ln Current Sensor for On-Line Testing)

  • 곽철호;김정범
    • 대한전자공학회논문지SD
    • /
    • 제38권7호
    • /
    • pp.493-502
    • /
    • 2001
  • 기존의 논리 테스팅에 비하여 여러 가지 장점을 가지는 전류 테스팅을 위하여 새로운 내장형 전류 감지 회로를 설계하였다. 본 논문에서 제안된 내장형 전류 감지 회로는 시험 대상 회로에서 발생하는 전류와 인버터의 전류 발생 특성에 의해 복사되어진 전류를 비교함으로서 시험 대상 회로의 고장 존재 여부를 감지하여 Pass/Fail 신호로 발생시킨다. 설계된 회로는 차동 증폭 형태의 증폭기와 비교기로 이루어져 있으며, 시험 대상 회로의 전류를 복사해 내기 위한 인버터를 포함하고 있어서 총 10개의 트랜지스터와 3개의 인버터를 사용한다. 본 논문에서 제안된 내장형 전류 감지 회로는 고장 테스트를 위하여 별도의 클럭을 사용하지 않는다. 또한 모드 선택이 필요하지 않아 on-line 테스팅이 가능하며, Pass/Fail 신호를 칩의 외부로 전달하는 출력단자 하나를 제외하고는 별도의 제어단자가 필요하지 않은 장점을 가진다. HSPICE를 사용한 컴퓨터 모의 실험을 통하여 시험 대상 회로에 삽입된 고장을 정확하게 검출해 낼 수 있음을 확인하였다. 제안된 내장형 전류 감지 회로가 칩의 전체 면적에서 차지하는 면적소모는 8×8 병렬 승산기를 시험 대상 회로로 사용한 경우에 약 4.34 %로 매우 작아서 내장형 전류 감지회로에 의한 면적 소모에 대한 부담은 거의 없는 것으로 측정되었다.

  • PDF

High-Frequency Flyback Transformer Linked PWM Power Conditioner with An Active Switched Capacitor Snubber

  • Mun, Sang-Pil;Kim, Soo-Wook;Joo, Seok-Min;Park, Young-Jun
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.7-15
    • /
    • 2008
  • A single active capacitor snubber-assisted soft-switching sinewave pulse modulation utility-interactive power conditioner with a three-winding flyback high frequency transformer link and a bidirectional active power switch in its secondary side has been proposed. With the aid of the switched-capacitor quasi-resonant snubber cell, the high frequency switching devices in the primary side of the proposed DC-to-AC sinewave power inverter can be turned-off with ZVS commutation. In addition to this, the proposed power conditioner in the DCM can effectively take the advantages of ZCS turn-on commutation. Its output port is connected directly to the utility AC power source grid. At the end, the prototype of the proposed HF-UPC is built and tested in experiment. Its power conversion conditioning and processing circuit with a high frequency flyback transformer link is verified and the output sinewave current is qualified in accordance with the power quality guidelines of the utility AC interactive power systems.

하이브리드 태양광 LED 가로등 컨트롤러의 효율 개선 (Improve the Efficiency of Hybrid Solar LED Street Lamp Controller)

  • 윤중현;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제28권2호
    • /
    • pp.131-136
    • /
    • 2015
  • We develop the 60 W class hybrid solar LED street lamp controller. The controller is providing power via an inverter in the day with the least solar cell and battery and charging the battery for the ESS, acts as a power failure, the built-in battery. Rated output of the fabricated LED street lamp is 300 W or greater battery capacity 300 Wh, discharge time 10 hr, LED street lamp efficiency showed a very high level of light efficiency by about 127 lm/W. In addition, as a result of light distribution pattern according to the distance and the light intensity measurement will be able to ensure a very high quality, show the constant brightness in the distance from the road lights 6 m is about 35~40 lux in uniformity ratio. The proposed hybrid solar LED street lamp system showed a high energy capacity of approximately 1.5 to 152.7% power generation efficiency than typical conventional solar street lamp.