• Title/Summary/Keyword: Inverter Motor

Search Result 1,333, Processing Time 0.026 seconds

Slot optimization of cage rotor for Inverter-fed 3-phase Induction Motor (인버터 구동 유도전동기의 회전자 슬롯형상 최적화)

  • Kim, Byung-Taek;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.250-252
    • /
    • 2000
  • A simple analysis method for inverter-fed induction motor using F.E.M and equivalent circuit is proposed. And an optimum shape of rotor slot for 2Hp inverter-fed induction motor is determined by combining the proposed analysis method and an optimization algorithm. Conjugate gradient method is used for the optimization algorithm. The optimization is performed for higher efficiency and reduction of harmonic loss in the inverter-fed induction motor. The optimization results are verified by comparing with those of the time-step F.E.A and the experiment.

  • PDF

Dynamic Analysis of an Inverter Motor Driven Compressor (인버터 압축기의 강체 거동 해석)

  • Kang, J.H.;Jeong, J.K.;Kim, Y.T.;Joo, J.M.;SeoMoon, H.;Lee, S.T.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.79-82
    • /
    • 2004
  • In general, compressors for refrigerators are major noise source in home environment. The vibration originated from a pump of a compressor can make noise through suspension springs and a LDT(Line Discharge Tube). Especially for the inverter motor driven compressor, the vibration is more serious than it of the constant speed compressors. Because the operation frequency range of an inverter motor driven compressor is very wide from 1600 rpm to 4200 rpm. In this paper, we propose the numerical model to reduce vibration by designing weight balancers and grommets. Results for analytical investigations on the exciting force and moment at the pump mass center, weight balancers and exciting frequency variation are presented.

  • PDF

DEVELOPMENT OF INVERTER AND POWER CAPACITORS FOR MILD HYBRID VEHICLE (MHV) - TOYOTA "CROWN"

  • Shida, Y.;Kanda, M.;Ohta, K.;Furuta, S.;Ishii, J.
    • International Journal of Automotive Technology
    • /
    • v.4 no.1
    • /
    • pp.41-45
    • /
    • 2003
  • The 42V Mild Hybrid System has been released into market by Toyota for the first time in the world in 2001. The set-up employs an inverter unit to control the motor/generator (MG) electronically. The driving system called such as Toyota Mild Hybrid System (TMHS) has additional new functions to conventional internal combustion engines. When stopping vehicle, the engine stops promptly. When starting vehicle, by releasing the brake pedal MG starts the vehicle at the same time (EV-driving mode). When stepping on the accelerator pedal, or after a given period of time the engine firing occurs and the engine-driving mode starts. When running by motor, the power is supplied to the motor from 36V battery through the inverter. High outputs and instant responses are required for Inverter. At the same time, the compact volume is required to fit into the limited space of the engine room. The compact size and high output are also required to Power Capacitor used for this inverter. The power capacitors has been newly developed, shaped in "flat" type, suitably for the inverter. The points of developments on inverter and power capacitor are described in this paper.his paper.

A Study on Energy Saving of the Motor Cooling System with an Inverter (INVERTER를 응용한 MOTOR 냉각 제어시스템의 전력절감에 관한 연구)

  • Kim, Ki-Hong;Jung, Jee-Hoon;Kwon, Bong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.611-613
    • /
    • 2004
  • This paper is concerned with the simulation and determination of the input voltage and frequency for the optimal efficiency operation of induction motors. In general, induction motors have a specific character that operation efficiency is dropped sharply at the light roads condition. Consequently, if the induction motor is controlled by high efficiency using the VVVF(variable voltage variable frequency) control methods at optimal values, the entire system can obtain the substantial energy savings from the efficiency improvement in induction motors. In this paper, optimal slip is derived from the modeling of an induction motor and the optimal hybrid-control method is suggested by the simulation of the proposed algorithm for a 3-phase induction motor.

  • PDF

Characteristics of Two Phase Operation of Two Winding Motor Driven by Reference Current Adaptive Inverter (기준전류추정형 인버어터에 의한 2 권선전동기의 2 상운전특성)

  • 원종수;정의상
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.289-298
    • /
    • 1984
  • The single phase induction motor is recently requested to meet a broad speed control and smooth forward and reverse operation due to the multifarious usages. This paper deals with two phase operation of a two winding motor by reference current adaptive inverter which can supply the currents to satisfy the balanced oeration into the main and auxiliary winding through the entire operational region. According to the roposed system, the starting, forward and reverse and variable speed control of a two winding motor eliminated the capacitor from the capacitor-run motor is also possible. The formation and its principle of the reference current adaptive inverter and characteristic analysis of the motor fed by this apparatus are described in this paper. Excellent agreement with the measured results and calculated values by computer simulation is obtained.

  • PDF

A Study on Fault Characteristic According Open Fault of Synchronous Motor (동기전동기의 개방고장에 따른 고장특성에 관한 연구)

  • Kim, Hoe-Cheon;Jung, Tae-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.109-115
    • /
    • 2012
  • Recently, permanent magnet synchronous motor are applied to various applications. Because of the importance of high reliable operation in these areas, many research related to the fault detection and diagnosis of inverter system are conducted. So, a faults model for an inverter-driven permanent magnet synchronous motor is studied by using the fault current of motor according to switch open, which can be effectively used for performance evaluation of the diagnostic algorithm. And fault of the permanent magnet synchronous motor inverter drive system is divided into four types. The feasibility of the proposed method are improved by simulation and experiment.

PWM current source converter and inverter system for induction motor drives (유도전동기 구동을 위한 전류형 PWM 컨버터 및 인버터 시스템)

  • 이동춘
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.159-164
    • /
    • 1996
  • In this paper, a novel control strategy of curretn source PWM converter and inverter system for induction motor dirves is proposed. The PWM converter controls line current to be sinusoidal and makes input power factor unity. In the inverter part, a minor voltage control loop is incorporated in the current control looop in order to suppress unstale resonance between the filter capacitor and the motor leakage inductance and to keep the stator voltage under the rated value. In additon, the modulation index control of the inverter currents ripples and inverter loss. With the proposed algorithm, both high dynamic responses and satisfactory static performance can be obtained.

  • PDF

Torque Control of Synchronous Reluctance Motor using DC Link voltage Synthesis (DC Link 전압 합성을 이용한 동기형 릴럭턴스 전동기 토크 제어)

  • Kim, Seung-Joo;Ahn, Joon-Seon;Kim, Ki-Chan;Go, Sung-Chul;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.19-21
    • /
    • 2006
  • This paper presents the control method that inverter output keeps to linear to reference voltage of Synchronous Reluctance Motor using DC Link voltage Synthesis. The Inverter output voltage cannot be displayed to linear about inverter reference voltage if Real DC Link voltage is different from DC Link voltage of PWM amplitude. Also, the overmodulation that there is linearity broken if reference voltage is out of range that inverter can output voltage. Torque ripple generates the vibration and noise of a motor. This paper proposes the control method so that torque ripple decreases and the linearity of inverter output keeps using the DC Link voltage Synthesis.

  • PDF

Analysis of Inverter Losses of Brushless DC Motor According to PWM Method and Power Devices (BLDC 모터의 PWM 방법과 파워소자에 따른 인버터 손실분석)

  • Nam, Myung Joon;Cho, Kwan Yuhl;Kim, Hag Wone;Eum, Sang Joon;Kim, Young Jin;Kim, Ki Man
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.33-34
    • /
    • 2014
  • In this paper, the inverter switch losses of BLDC motor for three types of PWM method and power devices was analyzed. When BLDC motor is driven at low currents, inverter switch losses for MOSFET is low because MOSFET operates like resistance. But, inverter switch losses for IGBT is higher than MOSFET due to its large turn-off losses. For low power inverter with MOSFET, the power losses of unified PWM is lower than that of unipolar and bipolar PWM.

  • PDF

An Inverter for Blower by using PWM controller (PWM 제어기를 이용한 브로워용 인버터)

  • Ra, B.H.;Kim, J.S.;Kang, T.A.;Koh, K.H.;Lee, H.W.;Kim, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.181-183
    • /
    • 2004
  • Conventional VVVF control voltage-fed inverter of blower induction motor has advantage that very speedy response characteristics for air-harmonic. But there have bad power factor on input orient have its large volume and high error ratio over 80%. And there are very expensive by reason of using the capacitor input rectifier. In this paper, It could make the smoothing capacitor-less inverter for air-blower motor by using the instantaneous compensation PWM controller. This inverter system has small volume and value compare with the conventional VVVF control inverter for blower induction motor for air-harmonic equipment.

  • PDF