• Title/Summary/Keyword: Inverter Filter

Search Result 529, Processing Time 0.245 seconds

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.2
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

Application Necessity of the Active Filter Function to Photovoltaic Power Generation System installed in Building Systems (태양광발전시스템이 설치된 대전력 수용가의 Active Filter기능 적용의 필요성)

  • Seong, Nak-Gueon;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.277-280
    • /
    • 2002
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. There are already a lot of PV power generation systems installed in building systems whose harmonics are the worst object for distribution systems as a utility interactive system and also it tends to spread out continuously. In this paper, the authors propose a multy-function inverter control strategy which puts a shunt active filter function to the power inverter of the PV power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of hypothetical power system using PSCAD/EMTDC.

  • PDF

A Study on Radiation Quality of the Diagnostic X-ray Equipments (진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究))

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

Design of Tunable Ceramic Bandpass Filter in UHF Band (UHF대역 가변 세라믹 대역통과 여파기의 설계)

  • 김윤조;황희용;성규제;윤상원;장익수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.76-83
    • /
    • 2000
  • A 2-pole tunable bandpass filter was design and fabricated using ceramic coaxial resonators and varactor diodes for UHF band. By inspection of frequency characteristics of the T-and $\pi$-type inverter equivalent circuits, we can design a two-pole tunable BPF with only two varactors. The measured data of the filter show 800 MHz-900 MHz tunable center frequency range, 4.5 dB insertion loss, 0.5 dB passband ripple and at least 15 dB return loss, which agree well with the simulated results.

  • PDF

Analysis on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by Multi level inverter (멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감을 위한 RC필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul;Kim, Young-Sung;Lee, Yang-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.399-403
    • /
    • 2005
  • In this paper, we analyze on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by H-bridge cascaded 7-level inverter. The switching surge voltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. The effect of switching surge appears more serious in high voltage induction motor than low voltage induction motor. Consequently, we demonstrated that the RC filter connected to the motor terminals greatly reduces the transient voltage stress md ringing. The results of simulation show the suppression of transient overvoltage at the motor end of a long cable. using EMTP

  • PDF

The Notch Filter Design for Mitigation Current Ripple of Fuel cell-PCS (연료전지용 PCS의 출력 전류 리플 개선을 위한 노치 필터 설계)

  • Kim, Seung-Min;Park, Bong-Hee;Choi, Ju-Yeop;Choy, Ick;Lee, Sang-Chul;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.106-112
    • /
    • 2012
  • As a fuel cell converts the chemical energy of the fuel cell into electrical energy by electrochemical reaction, the fuel cell system is uniquely integrated technique including fuel processor, fuel cell stack, power conditioning system. The residential fuel cell-PCS(Power Conditioning System) needs to convert efficiently the DC current produced by the fuel cell into AC current using single-phase DC-AC inverter. A single-phase DC-AC inverter has naturally low frequency ripple which is twice frequency of the output current. This low frequency(120Hz) ripple reduces the efficiency of the fuel cell. This paper presents notch filter with IP voltage controller to reject specific 120Hz current ripple in single-phase inverter. The notch filter is designed that suppress just only specific frequency component and no phase delay. Finally, the proposed notch filter design method has been verified with computer simulation and experimentation.

Single-Phase Improved Auxiliary Resonant Snubber Inverter that Reduces the Auxiliary Current and THD

  • Zhang, Hailin;Kou, Baoquan;Zhang, He;Zhang, Lu
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.1991-2004
    • /
    • 2016
  • An LC filter is required to reduce the output current ripple in the auxiliary resonant snubber inverter (ARSI) for high-performance applications. However, if the traditional control method is used in the ARSI with LC filter, then unnecessary current flows in the auxiliary circuit. In addressing this problem, a novel load-adaptive control that fully uses the filter inductor current ripple to realize the soft-switching of the main switches is proposed. Compared with the traditional control implemented in the ARSI with LC filter, the proposed control can reduce the required auxiliary current, contributing to higher efficiency and DC-link voltage utilization. In this study, the detailed circuit operation in the light load mode (LLM) and the heavy load mode (HLM) considering the inductor current ripple is described. The characteristics of the improved ARSI are expressed mathematically. A prototype with 200 kHz switching frequency, 80 V DC voltage, and 8 A maximum output current was developed to verify the effectiveness of the improved ARSI. The proposed ARSI was found to successfully operate in the LLM and HLM, achieving zero-voltage switching (ZVS) of the main switches and zero-current switching (ZCS) of the auxiliary switches from zero load to full load. The DC-link voltage utilization of the proposed control is 0.758, which is 0.022 higher than that of the traditional control. The peak efficiency is 91.75% at 8 A output current for the proposed control, higher than 89.73% for the traditional control. Meanwhile, the carrier harmonics is reduced from -44 dB to -66 dB through the addition of the LC filter.

Low-cost Single-Phase Half-bridge Active Power Filter with One Current Sensor (단일 전류센서를 갖는 저가의 단상 반브릿지 능동전력필터)

  • 김희중;한병문;박용식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.342-348
    • /
    • 1999
  • This paper describes a low-cost single-phase active power filter, which consists of a half-bridge P\A미1 inverter with a s simple control circuit. In order to verify the performance of proposed active power filter, many computer simulations w with EMTP codes and experimental works with a hardware prototype were done. Both results confirm that the p proposed active power filter shows excellent performance to eliminate the harmonics generated in the single-phase non l linear‘ load. The active power filter has advantage of low implementation cost and compact size. using a half-bridge i inverter and a simple control circuit with only one current sensor. So. it can be fabricated as a plug-in type.

  • PDF

A Study on the Harmonic Reduction Technique in Three-Phase Square-Wave Inverters Formed by Single-Phase Inverters (단상 인버터로 구성된 3상 구형파 인버터의 고조파 저감기법에 관한 연구)

  • 조승연
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.355-359
    • /
    • 2000
  • This paper deal with the harmonic reduction technique in three-phase square-wave inverter system formed by single-phase inverter. To reduce the harmonics six single-phase inverters are used for forming multi-phase inverter and zig-zag connected output transformer for eliminating the harmonic 6(2k-1)$\pm$1 orders. And an ac filter is furnished at output side. Computer simulations show that the THD of the output voltage can be reduced immensely.

  • PDF

Power Factor Correction Circuit For Inverter Air-Conditioner Using A Parallel Drive Method (병렬구동 방식을 이용한 인버터 에어컨용 역률제어회로)

  • 정용채;정윤철;권경안
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.9-12
    • /
    • 1998
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[ph] compressor motor may obtain the cost down and the improved performance. The adequate design procedures are presented to reduce the material costs by eliminating the power factor improving LC filter and derating output capacitor and inverter switches. Using the determined components, the prototype circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF