• Title/Summary/Keyword: Inversion intensity

검색결과 84건 처리시간 0.031초

Early Diagnosis of Aseptic Meningitis in Ramsay Hunt Syndrome on 10-Minute Delayed CE 3D FLAIR Image: a Case Report

  • Kang, Mi Hyun;Kim, Da Mi;Lee, In Ho;Song, Chang June
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.197-200
    • /
    • 2021
  • Ramsay Hunt syndrome (RHS) is a disease caused by varicella-zoster virus (VZV) infection that can be diagnosed through clinical symptoms with or without imaging evaluations. The typical features of RHS on imaging evaluation include signal changes and enhancement in the internal auditory canal (IAC) nerves, and the labyrinthine segment of cranial nerve VII (CN VII) and cranial nerve VIII (CN VIII). In some patients, inner ear structure (cochlear and vestibular apparatus) is involved in RHS. Neurologic complications, such as encephalitis and meningitis, are rare in RHS, but are known to occur. Therefore, magnetic resonance imaging (MRI) is necessary to detect both abnormal signal intensity in the IAC, CN VII, CN VIII, inner and ear structure, and CNS complications. We report an RHS patient with CN VII, VIII, and leptomeningeal enhancement within the cerebellar folia on 10-min delayed, contrast-enhanced (CE), three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging.

Eu3+와 Tb3+ 활성제 이온이 SrSnO3 형광체의 특성에 미치는 영향 (Effects of Eu3+ and Tb3+ Activator Ions on the Properties of SrSnO3 Phosphors)

  • 김정대;조신호
    • 한국재료학회지
    • /
    • 제24권9호
    • /
    • pp.469-473
    • /
    • 2014
  • $SrSnO_3$ phosphor powders were synthesized with two different contents of activator ions $Eu^{3+}$ and $Tb^{3+}$ using the solid-state reaction method. The structural, morphological, and optical properties of the phosphors were investigated using X-ray diffractometry, field-emission scanning electron microscopy, and fluorescence spectrophotometry, respectively. All the phosphors showed a cubic structure, irrespective of the type and the content ratio of activator ions. For $Eu^{3+}$-doped $SrSnO_3$ phosphors, the intensity of the 620 nm red emission spectrum resulting from the $^5D_0{\rightarrow}^7F_2$ transition of $Eu^{3+}$ was stronger than that of the 595 nm orange emission signal due to the $^5D_0{\rightarrow}^7F_1$ transition in the range 0.01-0.05 mol of $Eu^{3+}$, but the ratio of the intensity was reversed in the range 0.10-0.20 mol of $Eu^{3+}$. The variation in the emission intensity indicates that the site symmetry of the $Eu^{3+}$ ions around the host crystal was changed from non-inversion symmetry to inversion. For the $Tb^{3+}$-doped $SrSnO_3$ phosphors under excitation at 281 nm, one strong green emission band at 550 nm and several weak bands were observed. These results suggest that the optimum red and green emission signals can be realized when the activator ion content for $Eu^{3+}$- or $Tb^{3+}$-doped $SrSnO_3$ phosphors is 0.20 mol and 0.15 mol, respectively.

메탄/공기 층류 부분 예혼합화염에서 예혼합 정도에 따른 화염구조와 질소산화물의 배출에 미치는 영향에 관한 연구 (The Study of Effects of Variable Parameters on Flame Structure and NOx Emission in Methane/Air Laminar Partially Premixed Flames)

  • 오정석;정용기;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.362-367
    • /
    • 2003
  • It is shown that the effect of variable parameters on flame structures and NOx emissions in the laminar partially premixed methane-air flames with a co-axial Bunsen burner. Objectives of this paper is to understand the effects of flow variables on NOx emissions and the flame structure with OH chemiluminescence, including reconstructed image by abel inversion processing at each conditions. A fuel flowrate of 200 [cc/min] was fixed and the amount of air was varied from 400 to 1200 [cc/min]. The experimental variables were equivalence ratio(${\Phi}$ fuel split percentage(${\sigma}$ and inner tube recess(x/D). Flow conditions were ranged from $1.36{\sim}4.76$(equivalence ratio), $50{\sim}100$(fuel split percentage) and $0{\sim}20$(inner tube recess). NOx analyzer and ICCD camera with a OH filter were used as a main experimental apparatus. In addition, Abel inversion, which is a kind of tomography and valuable to estimate a two-dimensional structure of co-axial flames from cubical information, was employed for combustion diagnostics. Results from this study indicate that the main effects depend on equivalence ratio and next sigma, x/D for NOx production and OH formation. Throughout Abel inversion, we could affirm the maximum position and the tendency of OH radical intensity by variants at five axial heights above the burner exit.

  • PDF

A Direct Inversion Method to Remotely Measure the Concentration Profile of Suspended Sediment Using Acoustic Backscatterance

  • Lee, Tae-Hwan
    • 한국해안해양공학회:학술대회논문집
    • /
    • 한국해안해양공학회 1995년도 정기학술강연회 발표논문 초록집
    • /
    • pp.48-50
    • /
    • 1995
  • The use of acoustics to measure the concentration profile of suspended sediment become increasing common. Field studies have shown the usefulness of remotely measuring the suspended sediment concentration with high spatial and temporal resolution. Techniques that allow for the conversion of the backscattered acoustic intensity into suspended sediment concentration have been developed concurrent with instrumentation. (omitted)

  • PDF

3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구 (A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.253-259
    • /
    • 2015
  • 본 연구에서는 가돌리늄 조영제를 다양한 몰농도로 희석하여 T1 효과를 나타내는 펄스 시퀀스 중 고속스핀에코와 에코타임이 극도로 짧은 ultra short time echo에서 최대 신호 강도 분포를 나타내는 조영제 희석 몰농도를 3.0T에서 각각 알아보고자 하였다. T1 조영제인 gadoxetic acid 와 완충용액으로는 증류수, 2% agarose gel을 이용하여 다양한 몰농도로 조영제 팬텀을 제작하였다. 팬텀 제작의 정확성을 측정하기 위해 T1 이완시간 측정의 표준방식인 2D inversion recovery spine-echo 펄스시퀀스를 이용하였으며 팬텀의 중간 부의 한 개의 관상면 영상을 획득하여 T1 이완 시간을 계산하였다. 스핀에코에서는 1-2 mmol/L 조영제 몰농도에서 가장 높은 신호를 나타냈으며, ultra short time echo에서는 7 mmol/L에서 가장 큰 신호를 나타냈다. ultra short time echo 펄스 시퀀스를 이용한 조영증강 효과를 보기 위해서는 고속스핀에코 기법 보다 2-3배의 조영제 농도가 목적 장기에 유지하여야 하며 이와 관련된 조영제량 및 투여 방법의 연구가 이루어져야 한다.

Elastodynamic Response of a Crack Perpendicular to the Graded Interfacial Zone in Bonded Dissimilar Materials Under Antiplane Shear Impact

  • Kim, Sung-Ho;Choi, Hyung-Jip
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1375-1387
    • /
    • 2004
  • A solution is given for the elastodynamic problem of a crack perpendicular to the graded interfacial zone in bonded materials under the action of anti plane shear impact. The interfacial zone is modeled as a nonhomogeneous interlayer with the power-law variations of its shear modulus and mass density between the two dissimilar, homogeneous half-planes. Laplace and Fourier integral transforms are employed to reduce the transient problem to the solution of a Cauchy-type singular integral equation in the Laplace transform domain. Via the numerical inversion of the Laplace transforms, the values of the dynamic stress intensity factors are obtained as a function of time. As a result, the influences of material and geometric parameters of the bonded media on the overshoot characteristics of the dynamic stress intensities are discussed. A comparison is also made with the corresponding elastostatic solutions, addressing the inertia effect on the dynamic load transfer to the crack tips for various combinations of the physical properties.

Brain MRI Findings of Nitrogen Gas Inhalation for Suicide Attempt: a Case Report

  • Kim, Young-eun;Lee, Donghoon;Kim, Minji;Hwang, Hokyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권4호
    • /
    • pp.264-268
    • /
    • 2017
  • South Korea has the highest reported suicide rate among all countries belonging to the Organization for Economic Cooperation and Development. Nitrogen is a colorless, odorless and nontoxic gas. Nitrogen gas has, however, been recently used as a method of attempted suicide, its nontoxity notwithstanding. We herein report on an unusual case involving a 30-year-old male who presented with symptoms after a suicide attempt by nitrogen inhalation. Diffusion-weighted imaging of his brain was showed curvilinear high signal intensity in the bilateral frontal and right occipital cortices, with subtle low apparent diffusion coefficient value. In addition, T2-weighted images and fluid attenuated inversion recovery images revealed subtle high signal intensity in the bilateral frontal cortices, basal ganglia and occipital cortices with contrast enhancement.

분광 분석법에 의한 고압 수은등의 온도분포 측정 (Temperature Distribution Measurement of High-pressure Mercury Lamp using Spectroscopic Method)

  • 김상용;김창섭;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.13-18
    • /
    • 1989
  • Temperature distribution of 250W high-pressure mercury lamp has been measured by the spectroscopic method using relative intensities of spectral lines. To obtain radial temperature distribution, the measured intensity which was integrated along the line of sight was transformed into radial line intensity by Abel's inversion. Temperature was determined from relative intensities of spectral lines of the same atomic species. The measured temperature of 250W high-pressure mercury lamp is 6000K at the axis. In this experiment temperature profile of high-pressure arc is papabolic as known.

  • PDF

Transient response of a piezoelectric layer with a penny-shaped crack under electromechanical impacts

  • Feng, Wenjie;Li, Yansong;Ren, DeLiang
    • Structural Engineering and Mechanics
    • /
    • 제23권2호
    • /
    • pp.163-175
    • /
    • 2006
  • In this paper, the dynamic response of a piezoelectric layer with a penny-shaped crack is investigated. The piezoelectric layer is subjected to an axisymmetrical action of both mechanical and electrical impacts. Two kinds of crack surface conditions, i.e., electrically impermeable and electrically permeable, are adopted. Based upon integral transform technique, the crack boundary value problem is reduced to a system of Fredholm integral equations in the Laplace transform domain. By making use of numerical Laplace inversion the time-dependent dynamic stress and electric displacement intensity factors are obtained, and the dynamic energy release rate is further derived. Numerical results are plotted to show the effects of both the piezoelectric layer thickness and the electrical impact loadings on the dynamic fracture behaviors of the crack tips.

Assessment of Diffusion-Weighted Imaging-FLAIR Mismatch: Comparison between Conventional FLAIR versus Shorter-Repetition-Time FLAIR at 3T

  • Goh, Byeong Ho;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.88-94
    • /
    • 2016
  • Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter-TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, $0.9{\times}0.9mm$) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWI-matched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; $1.25{\pm}0.20$; $1.24{\pm}0.20$, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.