구강 내 촬영용 센서의 정량적 평가 (Quantitative Analysis for Digital Intraoral Sensor)

  • 정재호;정재은;강희두;나극환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.109-114
    • /
    • 2009
  • Carried out an experiment for quantitative evaluation about intraoral sensor among oral dental imaging equipments in PACS environment. For evaluation, testing environment & evaluation criteria are established that refer to the 'IEC 62220-1-2' and experimented with set up the standard radiation penetration that correspond with RQA-3(IEC 61267). Results of experiments using the image J, derived the ESF(edge spread function), LSF (line spread function) and calculated the MTF(modulation transfer function) finally. As a result, the MTF that 0.1, 0.2sec are 10% about 10 lp/mm and 0.32 sec is the 10% about 9 lp/mm in level represents the value of the MTF. Change of scan condition in dental environmental, according to the MTF value taken note that no changes can be seen enough. However, the dimensions of each other size $1(1200{\times}1600)$, size $2(1440{\times}1920)$ intraoral sensors for 3 lp/mm, respectively 40%, 90% of the note might have been the difference between the value of MTF, in accordance with standard sensors might note differences could be observed.

  • PDF

한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구 (The Study on Intraoral Pressure, Closure Duration and VOT During Phonation of Korean Bilabial Stop Consonants)

  • 표화영;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제7권1호
    • /
    • pp.50-55
    • /
    • 1996
  • Acoustic analysis study was performed on 20 normal subjects by speaking nonsense syllables composed of Korean bilabial stops$(/P, P^{\star}, P^{h}/)$ and their preceding and/or following vowel /a/ (that is, $[pa, p^{\star}a, p^{h}a, apa, ap^{\star}a, ap^{h}a]$) with an ultraminiature pressure, sensor. in their mouths. Speech materials were phonated twice, once with a moderate voice, another time with a loud voice. The acoustic signal and intraoral pressure were recorded simultaneously on computer. By these procedures, we were to measure the intraoral pressure, closure duration and VOT of Korean bilabial stops, and to compare the values one another according to the intensity of phonation and the position of the target consonants. Intraoral pressure was measured by the peak intraoral pressure value of Its wave closure duration by the time interval between the onset of intraoral pressure build-up and the burst meaning the release of closure ; Voice onset time(VOT) on by the time interval between the burst and the onset or glottal vibration. Heavily aspirated bilabial stop consonant /$p^h$/ showed the highest intraoral pressure value, unaspirated /$p^{\star}$/, the second, slightly aspirated /P/, the lowest. The syllable initial bilabial stops showed higher intraoral pressure than word initial stops, and the value of loudly phonated consonants were higher than moderate consonants. The longest closure duration period was that of /$p^{\star}$/ and the shortest, /P/, and the duration was longer in word initial position and in the moderate voice. In VOT, the order of the longest to shortest was $/{p^h}/, /p/, /{p^\star}/$, and the value was shorer when the consonant was in intervocalic position and when it was phonated with a loud voice.

  • PDF

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • 제47권4호
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구 (The Study on Intraoral Pressure, Closure Duration, and VOT During Phonation of Korean Bilabial Stop Consonants)

  • 표화영;최홍식
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 1996년도 10월 학술대회지
    • /
    • pp.390-398
    • /
    • 1996
  • Acoustic analysis study was performed on 20 normal subjects by speaking nonsense syllables composed of Korean bilabial stops(/p, $p^{*}$/, ph/) and their Preceding and/or following vowel /a/(that is, [pa, $p^{*}a$, pha, apa, $ap^{*}a$, apha]) with an ultraminiature pressure sensor in their mouths. Speech materials were phonated twice, once with a moderate voice, another time with a loud voice. The acoustic signal and intraoral pressure were recorded simultaneously on computer. By these procedures, we were to measure the intraoral pressure, closure duration and VOT of Korean bilabial stops, and to compare the values one another according to the intensity of phonation and the position of the target consonants. Intraoral pressure was measured by the peak intraoral pressure value of its wave; closure duration by the time interval between the onset of intraoral pressure build-up and the burst meaning the release of closure; Voice onset time(VOT) by the time interval between the burst and the onset of glottal vibration. Heavily aspirated bilabial stop consonant /ph/ showed the highest intraoral pressure value, unaspirated /p$^{*}$/, the second, slightly aspirated /p/, the lowest. The syllable initial bilabial stops showed higher intraoral pressure than word initial stops, and the value of loudly phonated consonants were higher than moderate consonants. The longest closure duration period was that of /$p^{*}$/ and the shortest, /p/, and the duration was longer in word initial position and in the moderate voice. In VOT, the order of the longest to shortest was /ph/, /p/, /$p^{*}$/, and the value was shorter when the consonant was in intervocalic position and when it was phonated with a loud voice.

  • PDF

프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발 (Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique)

  • ;이건수;박강
    • 한국CDE학회논문집
    • /
    • 제17권3호
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구 (COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM)

  • 도정주;김은경
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발 (THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY)

  • 김형준;김재문;정태성;김신
    • 대한소아치과학회지
    • /
    • 제35권1호
    • /
    • pp.1-10
    • /
    • 2008
  • 치아 우식증과 침식증의 진단과 예방에 있어 구강 내 환경, 특히 산도를 정밀하게 평가하는 것은 매우 중요한 일이다. 본 연구는 구강 내의 산도측정을 위한 기존 방법들의 단점을 보완하고자 구강 내 무선 pH 원격측정 방법을 개발하고, 실제로 측정시의 효율성을 얻기 위해 시행되었다. 구강 외로 부착되는 부가적인 장치 없이 구강 내에만 장착하여 24시간 이상 수소이온농도지수(이하 pH)를 측정할 수 있는 무선 원격측정장치를 개발하고, 정확한 산도의 측정이 가능한지를 검증하였다. 그리고 이 장치를 실제 구강 내에 장착하여 피검자로 하여금 24시간 동안의 시간별 상세한 섭식과 활동 내용, 수면 상태를 기록하도록 하고 24시간 후 구강으로부터 수거하여 지난 24시간 동안의 pH의 변화를 획득하고 분석하였다. 그 결과, 구강 내 장치와 구강 외 장치로 이루어진 구강 내 무선 pH 원격측정방법의 개발에 성공하였으며 24시간 동안 피검자의 구강 내 pH 변화를 측정한 결과, 피검자가 실제 섭취하였던 시간과 음식 종류에 일치하게 측정치를 얻을 수 있었다. 본 연구를 통하여 장시간 무선 pH 원격측정방법을 이용하여 구강 내 pH를 측정할 수 있게 됨으로써, 기존의 유선 pH 원격측정방법이 가진 한계점을 극복할 수 있게 되어 구강 내 환경이나 우식학과 관련된 보다 광범위한 연구가 가능하게 될 것이다.

  • PDF

한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구 (The Study on Intraoral Pressure, Closure Duration, and VOT During Phonation of Korean Bilabial Stop Consonants)

  • 표화영;최홍식
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 1996년도 제6회 학술대회 심포지움
    • /
    • pp.89-89
    • /
    • 1996
  • 정상인 20명을 대상으로 하여, 우리말의 양순 파열음인 /ㅂ, ㅃ, ㅍ/의 발음시, 각각의 음소에서의 구강내압의 크기와 폐쇄기 및 VOT의 길이를 측정하고, 목표 자음이 어두에 나올 때 및 음절 초에 나올 때, 그리고 어음을 보통 소리로 말했을 때와 큰 소리로 말했을 때, 그 세 측정치가 어떻게 변화하는지를 파악하기 위한 실험을 실시하였다 채취된 어음의 구강내압은 발음시 Pressure sensor를 사용함으로써 산출된 파형을 이용하여 측정하였고, 폐쇄기와 VOT는 컴퓨터에 입력된 음성신호를 Spectrogram으로 분석하여 측정하였다. 그 결과, 양순 파열음 중 구강내압은 /ㅍ/>/ㅃ/>/ㅂ/의 순이었고, 폐쇄기의 길이는 /ㅃ/>/ㅍ/>/ㅂ/, 그리고, VOT의 길이는 /ㅍ/>/ㅂ/>/ㅃ/의 순이었다. 양순 파열음이 어두에 올 패보다 음절 초에 올 때 더 큰 구강내압을 보였으며, 폐쇄기의 길이는 더 짧아지는 경향을 보였고, VOT의 길이도 폐쇄기와 마찬가지로 짧아지는 경향을 보였다 그리고, 양순 파열음을 큰 소리로 발음했을 때, 목표 자음의 위치에 상관없이, 구강내압의 크기는 의미 있게 커졌으며, 폐쇄기와 VOT는 짧아지는 경향을 보였다.

  • PDF

마우스가드와 스포츠치의학의 발전과 미래 (Mouthguard and Sports Dentistry: a perspective for the future)

  • 류재준;이수영
    • 대한치과의사협회지
    • /
    • 제56권6호
    • /
    • pp.339-347
    • /
    • 2018
  • Conventional mouthguard fabrication process which consists of elastomeric impression taking and followed gypsum model making is changing into intraoral scanning and dental model printing with 3D printer. In addition, new 3D printing materials for mouthgurad, 3D Computer-Aided Design(CAD) software for dental appliance, evaluation of a virtual dentoalveolar model for testing virtually 3D designed mouthguard, and lightweight sensor technology will lead dental professionals to the new era of Sports Dentistry, including information technology integrated custom mouthguard fabrication and creating value with analytic data acquired from sensors in mouthguard.

  • PDF

이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사 (Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism)

  • 김성원;김미은;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제30권1호
    • /
    • pp.69-77
    • /
    • 2005
  • 이갈이 치료에 가장 널리 이용되고 있는 구내교합장치는 치아와 턱관절 및 주위조직을 보호함으로써 이갈이 때문에 발생하는 여러 합병증을 예방하는 것을 주목적으로 하지만, 이갈이 억제에 있어서는 일시적인 증상감소의 효과만을 가질 뿐이므로 환자 스스로가 이갈이를 인지하여 습관을 중단할 수 있도록 하기 위한 특수한 장치의 개발이 시도되고 있다. 본 연구에서는 소형 방수 스위치를 이용하여 구내장치에 들어가는 부품을 최소화하고 전원의 사용시간을 최대화 함으로서 상품화 가능한 이갈이 진단 및 조절용 장치(이하 이갈이장치)를 개발하여 소개하고, 임상적으로 사용하기 전 장치에 대한 신뢰도를 조사하고자 하였다. 새로 개발한 장치는 이갈이 센서인 소형 방수스위치로 구성된 정보입력부, 중앙정보처리장치(CPU)인 정보처리부, 이갈이 신호를 수신하는 정보저장부, 이갈이 신호에 대한 소리나 진동으로 반응하는 반응장치부 및 컴퓨터상에서 저장된 이갈이 정보를 표시하여 이갈이 빈도와 시간, 양태 등을 확인시켜주는 정보표시부로 구성되어 있다. 이 중에서 resin sheet로 만든 상하의 wafer 사이에 정보입력부인 스위치는 좌우 견치 설면에 고정하고 정보처리부 CPU는 구개중앙에 고정하여 구내교합장치를 제작한 한편, 여기에서 송신되는 정보는 별도의 외부 장치인 반응장치 및 정보저장장치에서 인식하여 feedback을 보낼 수 있도록 하였다. 장치제작의 신뢰도조사를 위해서는 단국대학교 치과대학 학생 중 정상교합을 가진 지원자 10명의 상악 석고모형에 대하여 두 명의 술자가 각각 이갈이장치를 제작하여 그 장치가 반응하는 힘의 크기를 비교하였으며(술자간 신뢰도조사), 또한 한명의 술자가 첫 회에 조사한 정보를 기억하지 못하게 약 2일의 시간 간격을 두고 각각 제작하고 그 장치가 반응하는 힘의 크기를 비교하였다(술자내 신뢰도조사). 술자간 및 술자내 조사에서 이갈이장치가 반응하는 최소의 수직력, 측방력, 중심력에서 모두 높은 상관관계를 보였으며 측정된 값에 있어 서로 유의한 차이를 보여주지 않았다. 새로 개발한 이갈이장치는 부품을 소형화하였으며 제작이 편리하고 구강내에서 안전하게 사용할 수 있을 뿐만 아니라 전원의 사용시간을 최대로 할 수 있다는 장점을 가지고 있으며 술자간 및 술자내 신뢰도 조사를 통하여 임상에 적용가능한 높은 재현성을 확인할 수 있었다. 결론적으로 이 장치는 정보처리 및 저장장치가 있고 음향이나 진동을 이용한 바이오피드백 기능을 가지고 있어 이갈이 환자의 진단과 조절에 임상적으로 유용하게 사용될 수 있을 것으로 생각된다.