• Title/Summary/Keyword: Intraoral sensor

Search Result 19, Processing Time 0.023 seconds

Quantitative Analysis for Digital Intraoral Sensor (구강 내 촬영용 센서의 정량적 평가)

  • Jung, Jae-Ho;Jung, Jae-Eun;Kang, Hee-Doo;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.109-114
    • /
    • 2009
  • Carried out an experiment for quantitative evaluation about intraoral sensor among oral dental imaging equipments in PACS environment. For evaluation, testing environment & evaluation criteria are established that refer to the 'IEC 62220-1-2' and experimented with set up the standard radiation penetration that correspond with RQA-3(IEC 61267). Results of experiments using the image J, derived the ESF(edge spread function), LSF (line spread function) and calculated the MTF(modulation transfer function) finally. As a result, the MTF that 0.1, 0.2sec are 10% about 10 lp/mm and 0.32 sec is the 10% about 9 lp/mm in level represents the value of the MTF. Change of scan condition in dental environmental, according to the MTF value taken note that no changes can be seen enough. However, the dimensions of each other size $1(1200{\times}1600)$, size $2(1440{\times}1920)$ intraoral sensors for 3 lp/mm, respectively 40%, 90% of the note might have been the difference between the value of MTF, in accordance with standard sensors might note differences could be observed.

  • PDF

The Study on Intraoral Pressure, Closure Duration and VOT During Phonation of Korean Bilabial Stop Consonants (한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구)

  • 표화영;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.7 no.1
    • /
    • pp.50-55
    • /
    • 1996
  • Acoustic analysis study was performed on 20 normal subjects by speaking nonsense syllables composed of Korean bilabial stops$(/P, P^{\star}, P^{h}/)$ and their preceding and/or following vowel /a/ (that is, $[pa, p^{\star}a, p^{h}a, apa, ap^{\star}a, ap^{h}a]$) with an ultraminiature pressure, sensor. in their mouths. Speech materials were phonated twice, once with a moderate voice, another time with a loud voice. The acoustic signal and intraoral pressure were recorded simultaneously on computer. By these procedures, we were to measure the intraoral pressure, closure duration and VOT of Korean bilabial stops, and to compare the values one another according to the intensity of phonation and the position of the target consonants. Intraoral pressure was measured by the peak intraoral pressure value of Its wave closure duration by the time interval between the onset of intraoral pressure build-up and the burst meaning the release of closure ; Voice onset time(VOT) on by the time interval between the burst and the onset or glottal vibration. Heavily aspirated bilabial stop consonant /$p^h$/ showed the highest intraoral pressure value, unaspirated /$p^{\star}$/, the second, slightly aspirated /P/, the lowest. The syllable initial bilabial stops showed higher intraoral pressure than word initial stops, and the value of loudly phonated consonants were higher than moderate consonants. The longest closure duration period was that of /$p^{\star}$/ and the shortest, /P/, and the duration was longer in word initial position and in the moderate voice. In VOT, the order of the longest to shortest was $/{p^h}/, /p/, /{p^\star}/$, and the value was shorer when the consonant was in intervocalic position and when it was phonated with a loud voice.

  • PDF

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

The Study on Intraoral Pressure, Closure Duration, and VOT During Phonation of Korean Bilabial Stop Consonants (한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구)

  • Pyo Hwa Young;Choi Hong Shik
    • Proceedings of the KSPS conference
    • /
    • 1996.10a
    • /
    • pp.390-398
    • /
    • 1996
  • Acoustic analysis study was performed on 20 normal subjects by speaking nonsense syllables composed of Korean bilabial stops(/p, $p^{*}$/, ph/) and their Preceding and/or following vowel /a/(that is, [pa, $p^{*}a$, pha, apa, $ap^{*}a$, apha]) with an ultraminiature pressure sensor in their mouths. Speech materials were phonated twice, once with a moderate voice, another time with a loud voice. The acoustic signal and intraoral pressure were recorded simultaneously on computer. By these procedures, we were to measure the intraoral pressure, closure duration and VOT of Korean bilabial stops, and to compare the values one another according to the intensity of phonation and the position of the target consonants. Intraoral pressure was measured by the peak intraoral pressure value of its wave; closure duration by the time interval between the onset of intraoral pressure build-up and the burst meaning the release of closure; Voice onset time(VOT) by the time interval between the burst and the onset of glottal vibration. Heavily aspirated bilabial stop consonant /ph/ showed the highest intraoral pressure value, unaspirated /p$^{*}$/, the second, slightly aspirated /p/, the lowest. The syllable initial bilabial stops showed higher intraoral pressure than word initial stops, and the value of loudly phonated consonants were higher than moderate consonants. The longest closure duration period was that of /$p^{*}$/ and the shortest, /p/, and the duration was longer in word initial position and in the moderate voice. In VOT, the order of the longest to shortest was /ph/, /p/, /$p^{*}$/, and the value was shorter when the consonant was in intervocalic position and when it was phonated with a loud voice.

  • PDF

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM (직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구)

  • Do Jung-Joo;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY (구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발)

  • Kim, Hyung-Jun;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this study was to develop the wireless pH telemetry lasting longer than 24 hours in the mouth to overcome the limits of conventional wire telemetry previously used for salivary and plaque pH measurement, and to assess its effectiveness. We developed a wireless pH telemeter which can measure and store the pH profile data during more than 24 hours. It was composed of intraoral part; pH sensor of antimony electrode, battery and microprocessor for data storage, and extraoral part; control/data receiver and data analyzing software which was newly made for this device. After inspecting wireless electrode for accurate measurement, it was attached to the removable intraoral appliance and delivered to the volunteer who was told to wear except brushing time, retrieved after 24 hours and finally the pH profile data was extracted and analyzed. When compared with conventional wire telemetry, this device showed similar results and induced less discomfort to examinees. The data showed pH changes at same time when examinees ate various scheduled foods and beverages. With this method it became possible to accurately measure pH changes within mouth for long time in accordance with individual's lifestyle, definitely reducing the discomfort inflicted to the examinees' life.

  • PDF

The Study on Intraoral Pressure, Closure Duration, and VOT During Phonation of Korean Bilabial Stop Consonants (한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구)

  • 표화영;최홍식
    • Proceedings of the KSLP Conference
    • /
    • 1996.11a
    • /
    • pp.89-89
    • /
    • 1996
  • 정상인 20명을 대상으로 하여, 우리말의 양순 파열음인 /ㅂ, ㅃ, ㅍ/의 발음시, 각각의 음소에서의 구강내압의 크기와 폐쇄기 및 VOT의 길이를 측정하고, 목표 자음이 어두에 나올 때 및 음절 초에 나올 때, 그리고 어음을 보통 소리로 말했을 때와 큰 소리로 말했을 때, 그 세 측정치가 어떻게 변화하는지를 파악하기 위한 실험을 실시하였다 채취된 어음의 구강내압은 발음시 Pressure sensor를 사용함으로써 산출된 파형을 이용하여 측정하였고, 폐쇄기와 VOT는 컴퓨터에 입력된 음성신호를 Spectrogram으로 분석하여 측정하였다. 그 결과, 양순 파열음 중 구강내압은 /ㅍ/>/ㅃ/>/ㅂ/의 순이었고, 폐쇄기의 길이는 /ㅃ/>/ㅍ/>/ㅂ/, 그리고, VOT의 길이는 /ㅍ/>/ㅂ/>/ㅃ/의 순이었다. 양순 파열음이 어두에 올 패보다 음절 초에 올 때 더 큰 구강내압을 보였으며, 폐쇄기의 길이는 더 짧아지는 경향을 보였고, VOT의 길이도 폐쇄기와 마찬가지로 짧아지는 경향을 보였다 그리고, 양순 파열음을 큰 소리로 발음했을 때, 목표 자음의 위치에 상관없이, 구강내압의 크기는 의미 있게 커졌으며, 폐쇄기와 VOT는 짧아지는 경향을 보였다.

  • PDF

Mouthguard and Sports Dentistry: a perspective for the future (마우스가드와 스포츠치의학의 발전과 미래)

  • Ryu, Jae Jun;Lee, Soo Young
    • The Journal of the Korean dental association
    • /
    • v.56 no.6
    • /
    • pp.339-347
    • /
    • 2018
  • Conventional mouthguard fabrication process which consists of elastomeric impression taking and followed gypsum model making is changing into intraoral scanning and dental model printing with 3D printer. In addition, new 3D printing materials for mouthgurad, 3D Computer-Aided Design(CAD) software for dental appliance, evaluation of a virtual dentoalveolar model for testing virtually 3D designed mouthguard, and lightweight sensor technology will lead dental professionals to the new era of Sports Dentistry, including information technology integrated custom mouthguard fabrication and creating value with analytic data acquired from sensors in mouthguard.

  • PDF

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.