• Title/Summary/Keyword: Intraoral imaging

Search Result 99, Processing Time 0.026 seconds

Anatomical variations of trabecular bone structure in intraoral radiographs using fractal and particles count analyses

  • Amer, Maha Eshak;Heo, Min-Suk;Brooks, Sharon L.;Benavides, Erika
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.5-12
    • /
    • 2012
  • Purpose : This study was performed to evaluate possible variations in maxillary and mandibular bone texture of normal population using the fractal analysis, particles count, and area fraction in intraoral radiographs. Materials and Methods : Periapical radiographs of patients who had full mouth intraoral radiographs were collected. Regions of interest ($100{\times}100$ pixels) were located between the teeth of the maxillary anterior, premolar, and molar area, as well as the mandibular anterior, premolar, and molar areas. The fractal dimension (FD) was calculated by using the box counting method. The particle count (PC) and area fraction (AF) analyses were also performed. Results : There was no significant difference in the FD values among the different groups of age, gender, upper, and lower jaws. The mean FD value was $1.49{\pm}0.01$. The mean PC ranged from 44 to 54, and the mean AF ranged from 10.92 to 11.85. The values of FD, PC, and AF were significantly correlated with each other except for the upper molar area. Conclusion : According to the results, patients with normal trabecular pattern showed a FD of approximately 1.5. Based on these results, further investigation would be recommended if the FD value of patient significantly differenct from this number, since the alteration of this value indicates microstructural modification of trabecular pattern of the jaws. Additionally, with periapical radiographs, simple and cost-effective, PC and AF could be used to assess the deviation from the normal.

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

  • Creanga, Adriana Gabriela;Geha, Hassem;Sankar, Vidya;Teixeira, Fabricio B.;McMahan, Clyde Alex;Noujeim, Marcel
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.153-158
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Materials and Methods: Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. Results: A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. Conclusion: CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

A procedure for the computer-guided implant planning: A narrative review (임플란트 가이드 수술을 위한 Planning 방식에 대한 고찰)

  • Kim, Jong-Eun;Kim, Nam-Hoon;Park, Ji-Hyun;Shim, June-Sung
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.108-122
    • /
    • 2016
  • Prosthetic-driven implant placement is a concept considering the dental implant restoration first based on the final form of that prosthesis to be restored. The latest development of the imaging technology and digital dentistry was able to be obtained the high quality images of CBCT with low radiation exposure and it has also enabled the process to reconstruct the intraoral state in three dimensions due to the development of the intraoral, model and impression scanner. Computer-guided implant placement simulations and template production was able to be more widely used in this context. In this narrative review, the features and the types of implant surgical guides will be introduced. It will also be described the diagnosis and treatment plan using computerguided implant software to reduce the number of visit and to increase the accuracy of the implant surgery through the top-down approach based on the shape and location of the final prosthesis.

  • PDF

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Anatomical study to determine a new approach to treat benign masses located in the anterior condyle region: a case report

  • Sin Guen Kim;Sung Chul Bok;Suk In Choi;Jun Woo Park;Dong Ju Choi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.2
    • /
    • pp.110-115
    • /
    • 2024
  • A 22-year-old male patient presented to the clinic with severe pain in the preauricular area with an inability to completely occlude the jaw. Facial computed tomography and magnetic resonance imaging revealed a well-defined lesion that was tentatively diagnosed as a benign tumor or cystic mass. Surgical approach of a lesion in the condyle is delicate and problematic as many vulnerable anatomical structures are present. There are several methods for surgery in this area. Typically, an extraoral approach is dangerous because of potential injuries to nerves and arteries. The intraoral approach also presents difficulties due to the lack of visibility and accessibility. On occasion, coronoidectomy may be performed. The goal here was to determine an easier and safer new surgical approach to the condyle. We reached the anterior part of the pterygoid plate in the same method as in Le Fort I surgery. From this point, through the external pterygoid muscle, approaching the anterior aspect of the condyle is relatively easy and safe, with minimal damage to the surrounding tissues. Pus was drained at the site, and the lesion was diagnosed as an abscess. Pain and inability to close the mouth resolved without recurrence.

COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM (직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구)

  • Do Jung-Joo;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

Development of an evidence-based clinical imaging diagnostic guideline for implant planning: Joint recommendations of the Korean Academy of Oral and Maxillofacial Radiology and National Evidence-based Healthcare Collaborating Agency

  • Kim, Min-Ji;Lee, Sam-Sun;Choi, Miyoung;Ha, Eun Ju;Lee, Chena;Kim, Jo-Eun;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Purpose: This study was conducted to develop an evidence-based clinical imaging diagnostic guideline for implant planning, taking into account efficacy, benefits, and risks. Materials and Methods: The guideline development process employed the adaptation methodology used for Korean clinical imaging guidelines(K-CIG). Core databases(Ovid-Medline, Ovid-Embase, National Guideline Clearinghouse, Guideline International Network) and domestic databases (KoreaMed, KMbase, and KoMGI) were searched for guidelines. The retrieved articles were analyzed by 2 reviewers, and articles were selected using well-established inclusion criteria. Results: The search identified 294 articles, of which 3 were selected as relevant guidelines. Based on those 3 guidelines, 3 recommendations for implant planning were derived. Conclusion: We recommend radiography or cone-beam computed tomography (CBCT) scanning for individual patients judged to require a cross-sectional image after reading of a panoramic X-ray image and a conventional intraoral radiological image. Various steps should be taken to raise awareness of these recommendations among clinicians and the public, and K-CIG should be regularly reviewed and revised.

Diagnostic considerations in central odontogenic fibroma of the maxilla: 2 case reports

  • Seo, Yu-Kyeong;Kang, Ju Hee;Lee, Sae Rom;Choi, Yong-Suk;Hwang, Eui-Hwan;Oh, Song Hee
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.229-234
    • /
    • 2019
  • Central odontogenic fibroma (COF) is defined as a fibroblastic odontogenic tumor characterized by varying density of the tooth epithelium. It is an extremely rare benign neoplasm that occurs in the maxilla and the mandible; only a few reports of COF are available in the literature. Diagnosis of the lesion based only on the radiological features of COF is difficult due to variation in the findings regarding this condition. This report describes 2 clinical cases of middle-aged women with COF. Clinical examination revealed palatal mucosal depression; additionally, oral examination, as well as panoramic radiographs, intraoral radiographs, and computed tomography scans, revealed severe root resorption. This report highlights the clinical and radiological imaging features of COF, with the goal of enabling straightforward differential diagnosis of the lesion by the clinician and thereby appropriate treatment of the patient.

A study on the accuracy of profile change Prediction by video imaging (Power Ceph $^{\circledR}Ver$ 3.3) in Class III two jaw surgery patients (골격성 III급 부정교합을 가진 양악 수술 환자의 술후 측모 예측을 위한 Video imaging (Power $Ceph^{\circledR}$ Ver 3.3)의 정확도에 관한 연구)

  • Kwon, Mi-Jeong;Baik, Hyoung-Seon;Lee, Won You
    • The korean journal of orthodontics
    • /
    • v.29 no.3 s.74
    • /
    • pp.285-301
    • /
    • 1999
  • There is a need for more accurate prediction in surgical orthodontic treatment. Video imaging is an important technology in planning orthognathic surgery and educating patients about the esthetic results after treatment. Preoperative and postoperative lateral cephalogram of 30 patients who had one piece Le Fort I osteotomy advancement and mandibular set back by bilateral intraoral vertical ramal osteotomy with or without genioplasty were used in this study. The computer generated soft tissue line drawing prediction were compared with the actual postoperative cephalograms .The results are as follows. 1. 14 variables showed Statistically significant differences from 24 variables between computer predicted profile and post operative profile 2. Most of the differences were found in the maxilla-related soft tissue landmarks. 3. The predicted results were more accurate in the groups who had small amount of mandibular set back. 4. The predicted results were more accurate in the groups who had no genioplasty. Most of these differences were within 2mm ranges. Therefore profile change prediction by video imaging could be considered clinically acceptable.

  • PDF

Adenocarcinoma of the parotid gland with calcification (석회화를 수반한 이하선내 선양암종)

  • Song Haeng-Eun;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.55-59
    • /
    • 2002
  • A 78-year-old woman was referred to Chonbuk National University Dental Hospital complaining of facial palsy and palpable mass on the right parotid gland area. Clinical examination showed non-specific findings of the intraoral region, but showed asymmetrical facial appearance. Panoramic view showed a large amorphous calcified mass on the posterior to the mandibular ramus and thin cortical plate of the posterior ramus. Sialogram showed constriction of the main duct and no further filling of striated, intercalated ducts and parenchymal areas. CT scans demonstrated an irregular, infiltrating mass with slight enhancement in the right parotid gland. The mass showed necrotic areas and calcifications. Bone scan showed marked accumulation of /sup 99m/Tc-MDP on the right posterior maxilla. Microscopic findings demonstrated the minimal morphologic alterations and rare mitotic figures within tumor cells, and diagnosed as adenocarcinoma (NOS, Grade II). This report could be aid in the diagnosis of calcified lesions of the salivary gland.

  • PDF