• Title/Summary/Keyword: Intraclass Model

Search Result 48, Processing Time 0.026 seconds

Psychometric Properties of the Persian Version of Champion's Health Belief Model Scale for Colorectal Cancer Screening

  • Kharameh, Zahra Taheri;Foroozanfar, Sahar;Zamanian, Hadi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4595-4599
    • /
    • 2014
  • Background: Colorectal cancer is a serious health problem. Early detection of colorectal cancer is crucial for treatment and reducing mortality. Beliefs related to colorectal cancer have been found to be a factor in a person's decision about colorectal cancer screening programs. To determine such beliefs, a valid and reliable instrument is necessary. Objective:The aim of this study was to adapt and determine the psychometric properties of the Persian version of Champion's Health Belief Model Scale of breast cancer screening in the measurement of beliefs toward colorectal cancer (CRC) screening. Materials and Methods: The 'forward-backward' procedure was applied to translate the instrument from English into Persian. This study was conducted in Iran from June 2012 to May 2013. A convenience sample of 200 individuals aged 50 years and older was recruited from the population at the outpatient clinics in the three teaching hospitals. Validity was assessed using content, face and construct validity. To test reliability, the internal consistency was assessed by using Cronbach's alpha coefficient and test-retest (intraclass correlation coefficient) analyses. Exploratory factor analysis was used to assess the construct validity and determine the factors of adapted Champion's Health Belief Model Scale. Results: The mean age of the participants were 62.5 years (SD=10.8 years) and the majority of them (75.5 percent) were female. The results of exploratory factor analysis indicated a six-factor solution for the questionnaire (benefits, motivation and confidence, seriousness, susceptibility, emotional barriers and background barriers) that jointly accounted for 55.52% of variance observed. Cronbach's alpha of the subscales ranged from 0.57 to 0.89 and test-retest reliability ranged from 0.81 to 0.93 indicating a good range of reliability. Conclusions: The findings of this study suggest that the Persian version of Champion's Health Belief Model Scale of CRC screening has good psychometric properties and could be an appropriate measure for health beliefs related to CRC screening in national and international studies.

Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner (CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가)

  • Kim, Sa-Hak;Kim, Jae-Hong;Kim, Chong-Kyen
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.673-678
    • /
    • 2015
  • The purpose of this study was to evaluate the reliability and accuracy of linear measurements in digital models compared to master model. A master model (ANKA-4; Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Four linear measurements were recorded between landmarks, directly on the master model and the digital models by a single examiner. Measurements were made with a digital caliper from manual model and with the software from the virtual models. The t-test for paired samples and intraclass correlation coefficient (ICC) were used for statistical analysis. The measurement of two methods showed good reliability. The mean differences between master and digital model were 0.06~0.12 mm. These in vitro studies show that accuracy and reliability of the digital impression is similar to that of the gold standard. Therefore digital impression was also considered to be a acceptable for placement clinically.

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root

  • Lim, Seung-Weon;Moon, Ryu-Jin;Kim, Min-Seok;Oh, Min-Hee;Lee, Kyung-Min;Hwang, Hyeon-Shik;Kim, Tae-Woo;Baek, Seung-Hak;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.50 no.4
    • /
    • pp.229-237
    • /
    • 2020
  • Objective: To evaluate the construction reproducibility of a composite tooth model (CTM) composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. Methods: The study assessed 240 teeth (30 central incisors, 30 canines, 30 second premolars, and 30 first molars in the maxillary and mandibular arches) from 15 young adult patients whose pre-treatment intraoral scan and CBCT were available. Examiner-Reference (3 years' experience in CTM construction) and Examiners-A and Examiner-B (no experience) constructed the individual CTMs independently by performing the following steps: image acquisition and processing into a three-dimensional model, integration of intraoral-scanned crowns and CBCT-scanned teeth, and replacement of the CBCT-scanned crown with the intraoral-scanned crown. The tooth axis angle in terms of mesiodistal angulation and buccolingual inclination of the CTMs constructed by the three examiners were measured. To assess the construction reproducibility of CTMs, intraclass correlation coefficient (ICC) assessments were performed. Results: The ICC values of mesiodistal angulation and buccolingual inclination among the 3 examiners showed excellent agreement (0.950-0.992 and 0.965-0.993; 0.976-0.994 and 0.973-0.995 in the maxillary and mandibular arches, respectively). Conclusions: The CTM showed excellent construction reproducibility in mesiodistal angulation and buccolingual inclination regardless of the construction skill and experience levels of the examiners.

Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners

  • Camardella, Leonardo T.;Ongkosuwito, Edwin M.;Penning, E. Willemijn;Kuijpers-Jagtman, Anne Marie;Vilella, Oswaldo V.;Breuning, K. Hero
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.13-25
    • /
    • 2020
  • Objective: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). Methods: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. Results: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. Conclusions: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably.

Repeatability of a Multi-segment Foot Model with a 15-Marker Set in Normal Children

  • Kim, Eo Jin;Shin, Hyuk Soo;Lee, Jae Hee;Kyung, Min Gyu;Yoo, Hyo Jeong;Yoo, Won Joon;Lee, Dong Yeon
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.484-490
    • /
    • 2018
  • Background: The use of three-dimensional multi-segment foot models (3D MFMs) is increasing since they have superior ability to illustrate the effect of foot and ankle pathologies on intersegmental motion of the foot compared to single-segment foot model gait analysis. However, validation of the repeatability of the 3D MFMs is important for their clinical use. Although many MFMs have been validated in normal adults, research on MFM repeatability in children is lacking. The purpose of this study is to validate the intrasession, intersession, and interrater repeatability of an MFM with a 15-marker set (DuPont foot model) in healthy children. Methods: The study included 20 feet of 20 healthy children (10 boys and 10 girls). We divided the participants into two groups of 10 each. One group was tested by the same operator in each test (intersession analysis), while the other group was tested by a different operator in each test (interrater analysis). The multiple correlation coefficient (CMC) and intraclass correlation coefficient (ICC) were calculated to assess repeatability. The difference between the two sessions of each group was assessed at each time point of gait cycle. Results: The intrasession CMC and ICC values of all parameters showed excellent or very good repeatability. The intersession CMC of many parameters showed good or better repeatability. Interrater CMC and ICC values were generally lower for all parameters than intrasession and intersession. The mean gaps of all parameters were generally similar to those of the previous study. Conclusions: We demonstrated that 3D MFM using a 15-marker set had high intrasession, intersession, and interrater repeatability in the assessment of foot motion in healthy children but recommend some caution in interpreting the hindfoot parameters.

Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study

  • Yun, Dalsun;Choi, Dong-Soon;Jang, Insan;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.48 no.4
    • /
    • pp.262-267
    • /
    • 2018
  • The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.

Validity, Reliability and Reproducibility of Space Analysis using Digital Model taken via Model Scanner and Intraoral Scanner: An In vivo Study (모델 스캐너와 구내 스캐너로 획득한 디지털 모형에서 시행한 공간 분석의 타당도, 신뢰도, 재현성 평가)

  • Park, Seohyun;Kim, Jongsoo;Oh, Sohee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.176-187
    • /
    • 2020
  • The purpose of this study is to evaluate validity, reliability and reproducibility of tooth width (TW), arch length (AL) and arch length discrepancy (ALD) measured on a digital model taken via 3-dimensional model scanner and intraoral scanner compared to a plaster model. A total of 30 patients aged 12 to 18 were eligible for the study. 3 types of models were acquired from each patient: a conventional plaster model (P), a model scanned digital model (MSD) taken via Freedom UHD® and an intraoral scanned digital model (ISD) taken via CS3600® in-vivo. The reliability of TW and AL in each group was evaluated using Pearson's correlation coefficient, while the reproducibility was evaluated with intraclass correlation coefficient. The validity of space analysis was assessed by paired t-test. As a result, all measurements of P, MSD and ISD groups showed favorable reliability and reproducibility. Most of measurements for space analysis in MSD group and TW in ISD group also presented high validity. AL and ALD presented statistically significant difference between P and ISD group. The validity of measurements of space analysis in ISD group was short in doubt to valid, but clinically acceptable. Both MSD and ISD are clinically acceptable to use for space analysis but clinician should be aware that errors can be found using a digital model.

Development of Computerized Anthropometric Analysis Model in Cleft Lip Nasal Deformity Using 3D Laser Scanned Facial Cast Model (구순구개열의 비구순변형에서 3차원 입체 laser 스캐너를 이용한 계측분석 프로그램의 개발)

  • Kim, Suk Wha;Park, Jong Lim;Kim, Jae Chan;Baek, Seung Hak;Son, Woo Gil
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.303-308
    • /
    • 2008
  • Purpose: The purpose of this study is to develop three-dimensional computerized anthropometry(3DCA) and to compare its reliability and accuracy 3DCA with manual anthropometry(MA) for measurement of lips and nasal deformities in unilateral cleft lips and palate(UCLP) patients. Methods: Samples were consisted of six UCLP patients whose facial plaster models were available immediately before and 3 months after the cleft lip surgery. MA of the facial plaster models was carried out using an electronic caliper. In 3DCA, three-dimensional auto-measuring program was used to digitize landmarks and to measure three-dimensional virtual facial models (3DVFM), which was generated with a laser scanner and 3D virtual modeling program. Intraclass correlation coefficients(ICC) were calculated to evaluate reliability and reproducibility of the variables in both methods, and Wilcoxon's signed rank test was done to investigate the difference in values of the same variables of facial models of each patient between two methods. Results: All ICC values were higher than 0.8, so both methods could be considered reliable. Although most variables showed statistical differences between two methods(p<0.05), differences between mean values were very small and could be considered not significant in clinical situation. Conclusion: In clinical situation, 3DCA can be an objective, reliable and accurate tool for evaluation of lips and nasal deformities in the cleft patients.

New prediction equations for the estimation of maxillary mandibular canine and premolar widths from mandibular incisors and mandibular first permanent molar widths: A digital model study

  • Shahid, Fazal;Alam, Mohammad Khursheed;Khamis, Mohd Fadhli
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.171-179
    • /
    • 2016
  • Objective: The primary aim of the study was to generate new prediction equations for the estimation of maxillary and mandibular canine and premolar widths based on mandibular incisors and first permanent molar widths. Methods: A total of 2,340 calculations (768 based on the sum of mandibular incisor and first permanent molar widths, and 1,572 based on the maxillary and mandibular canine and premolar widths) were performed, and a digital stereomicroscope was used to derive the the digital models and measurements. Mesiodistal widths of maxillary and mandibular teeth were measured via scanned digital models. Results: There was a strong positive correlation between the estimation of maxillary (r = 0.85994, $r^2=0.7395$) and mandibular (r = 0.8708, $r^2=0.7582$) canine and premolar widths. The intraclass correlation coefficients were statistically significant, and the coefficients were in the strong correlation range, with an average of 0.9. Linear regression analysis was used to establish prediction equations. Prediction equations were developed to estimate maxillary arches based on $Y=15.746+0.602{\times}sum$ of mandibular incisors and mandibular first permanent molar widths (sum of mandibular incisors [SMI] + molars), $Y=18.224+0.540{\times}(SMI+molars)$, and $Y=16.186+0.586{\times}(SMI+molars)$ for both genders, and to estimate mandibular arches the parameters used were $Y=16.391+0.564{\times}(SMI+molars)$, $Y=14.444+0.609{\times}(SMI+molars)$, and $Y=19.915+0.481{\times}(SMI+molars)$. Conclusions: These formulas will be helpful for orthodontic diagnosis and clinical treatment planning during the mixed dentition stage.