• Title/Summary/Keyword: Intraclass Correlation Coefficient

Search Result 240, Processing Time 0.026 seconds

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

Measuring Quality of Life in Cerebral Palsy Children According to the Severity Using the Visual Analogue Scale, Time Trade-Off, and EQ-5D-Y Proxy (뇌성마비 환아 중증도별 시각화척도, 시간교환법, EQ-5D-Y Proxy를 이용한 삶의 질 측정)

  • Lee, Go-Eun;Kim, Nam Kwen;Yun, Young Ju;Wang, Hye Min;Kim, Jeong Hun;Lee, Dong Hyo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.28 no.2
    • /
    • pp.49-59
    • /
    • 2017
  • Objectives: To measure the quality of life in patients according to virtual cerebral palsy severity by using the Korean version of EQ-5D-Y proxy, Visual Analogue Scale (VAS), and Time Trade-Off method (TTO). Methods: The study was conducted in parents of children and adolescents aged 4 to 15 years in Seoul. We analyzed the difference in the utility value according to five levels of cerebral palsy severity in the Gross Motor Function Classification System (GMFCS) and test-retest reliability. Results: 1. There were significant differences in VAS, TTO, and EQ-5D-Y proxy according to the cerebral palsy severity (p<.001). 2. VAS was significantly different according to the respondent's visit to the medical institution, the presence of disease in the respondent, a visit to the child's medical institution, the age of the child, and the sex of the child. The value of TTO was significantly different according to the respondent's visit to the medical institution, respondent's sex, and the age of the child. Also, EQ-5D-Y proxy was significantly different according to the age of the child. 3. Intraclass correlation coefficient values were more than 0.6 for both VAS and TTO at all stages. But for the EQ-5D-Y proxy, the value was less than 0.6 at all stages. Conclusions: The quality of life assessment using EQ-5D-Y proxy showed significant differences in the severity of cerebral palsy. However, large-scale studies using EQ-5D-Y proxy are needed because of low test-retest reliability.

The Effect of Education on Motor Skill Assessment Tool for Occupational Therapists (작업치료사를 위한 운동성 평가도구의 교육효과)

  • Choi, Jeong-sil;Kim, Min-Joo
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.2
    • /
    • pp.63-72
    • /
    • 2020
  • Objective : The purpose of this study is to investigate the effect of intensive one-day training on Movement Assessment Battery for Children-2 screening developmental coordination disorder. Methods : We provided intensive one-day training which combined lecture and practice on MABC-2 assessment tools for 33 trainees. Interrater reliability was calculated by using Intraclass correlation coefficient (ICC) with the raw score of results scored simultaneously by experts and trainees of MABC-2. Results : The 33 female trainees with an average of five years and three months of experience and less experience using motor skill assessment tools scored raw score while watching the performance scenes of normal children. The results of the ICC between experts and training participants in MABC-2 obtained a high confidence 0.95 and above (p<.001). Conclusion : Clinicians who participated in one-day training seems to use MABC-2 effectively. Through this, one-day training seems to be effective in acquiring new motor skill assessment tools.

Evaluating the Validity and Reliability of the Korean Version of Upper Extremity Performance Test for the Elderly (TEMPA) (한국판 TEMPA의 신뢰도 및 타당도 연구)

  • Lee, Chang-Dae;Jung, Min-Ye;Park, Ji-Hyuk;Kim, Jongbae
    • Therapeutic Science for Rehabilitation
    • /
    • v.8 no.4
    • /
    • pp.65-76
    • /
    • 2019
  • Objective : This study aimed to verify the validity and reliability of the Upper Extremity Performance Test for the Elderly (TEMPA) by modifying its items to exhibit cultural differences. Methods : This study included 171 healthy adults and older adults and 41 individuals with impaired upper extremity function. Content validity, discriminant validity, test-retest reliability, and inter-rater reliability were analyzed. Results : The following items, exhibiting cultural differences, were modified: "open a lock and take the top off a pillbox" and "write and affix a postage stamp." The discriminant validity results indicated that participants with normal upper extremity function performed better than those with impaired in the upper extremity function (p<.001). The test-retest reliability of the execution speed (intraclass correlation coefficient; ICC) was .71-.94, functional rating (kappa) was 1.0, and task analysis (ICC) was 1.0. The inter-rater reliability of the speed of execution was 1.0, functional rating was .79-1.0, and task analysis was .94-1.0. Conclusion : TEMPA has moderate to high level of reliability and is an assessment tool that can clearly distinguish individuals with upper extremity impairment from those without impairment.

Influence of heritability on craniofacial soft tissue characteristics of monozygotic twins, dizygotic twins, and their siblings using Falconer's method and principal components analysis

  • Song, Jeongmin;Chae, Hwa Sung;Shin, Jeong Won;Sung, Joohon;Song, Yun-Mi;Baek, Seung-Hak;Kim, Young Ho
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.3-11
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the influence of heritability on the craniofacial soft tissue cephalometric characteristics of monozygotic (MZ) twins, dizygotic (DZ) twins, and their siblings (SIB). Methods: The samples comprised Korean adult twins and their siblings (mean age, 39.8 years; MZ group, n = 36 pairs; DZ group, n = 13 pairs of the same gender; and SIB group, n = 26 pairs of the same gender). Thirty cephalometric variables were measured to characterize facial profile, facial height, soft-tissue thickness, and projection of nose and lip. Falconer's method was used to calculate heritability (low heritability, $h^2$ < 0.2; high heritability, $h^2$ > 0.9). After principal components analysis (PCA) was performed to extract the models, we calculated the intraclass correlation coefficient (ICC) value and heritability of each component. Results: The MZ group exhibited higher ICC values for all cephalometric variables than DZ and SIB groups. Among cephalometric variables, the highest ${h^2}_{(MZ-DZ)}$ and ${h^2}_{(MZ-SIB)}$ values were observed for the nasolabial angle (NLA, 1.544 and 2.036), chin angle (1.342 and 1.112), soft tissue chin thickness (2.872 and 1.226), and upper lip thickness ratio (1.592 and 1.026). PCA derived eight components with 84.5% of a cumulative explanation. The components that exhibited higher values of ${h^2}_{(MZ-DZ)}$ and ${h^2}_{(MZ-SIB)}$ were PCA2, which includes facial convexity, NLA, and nose projection (1.026 and 0.972), and PCA7, which includes chin angle and soft tissue chin thickness (2.107 and 1.169). Conclusions: The nose and soft tissue chin were more influenced by genetic factors than other soft tissues.

Reliability of OperaVOXTM against Multi-Dimensional Voice Program to Assess Voice Quality before and after Laryngeal Microsurgery in Patient with Vocal Polyp (성대 용종 환자의 후두미세수술 전후 음성 평가에서 OperaVOXTM와 Multi-Dimensional Voice Program 간의 신뢰도 연구)

  • Kim, Sun Woo;Kim, So Yean;Cho, Jae Kyung;Jin, Sung Min;Lee, Sang Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.31 no.2
    • /
    • pp.71-77
    • /
    • 2020
  • Background and Objectives OperaVOXTM (Oxford Wave Research Ltd.) is a portable voice analysis software package designed for use with iOS devices. As a relatively cheap, portable and easily accessible form of acoustic analysis, OperaVOXTM may be more clinically useful than laboratory-based software in many situations. The aim of this study was to evaluate the agreement between OperaVOXTM and Multi-Dimensional Voice Program (MDVP; Computerized Speech Lab) to assess voice quality before and after laryngeal microsurgery in patient with vocal polyp. Materials and Method Twenty patients who had undergone laryngeal microsurgery for vocal polyp were enrolled in this study. Preoperative and postoperative voices were assessed by acoustic analysis using MDVP and OperaVOXTM. A five-seconds recording of vowel /a/ was used to measure fundamental frequency (F0), jitter, shimmer and noise-to-harmonic ratio (NHR). Results Several acoustic parameters of MDVP and OperaVOXTM related to short-term variability showed significant improvement. While pre-operative value of F0, jitter, shimmer, NHR was 155.75 Hz (male: 125.37 Hz, female: 183.37 Hz), 2.20%, 6.28%, 0.16, post-operative values of these parameter was 164.34 Hz (male: 129.42 Hz, female: 199.26 Hz), 2.15%, 5.18%, 0.14 Hz in MDVP. While pre-operative value of F0, jitter, shimmer, NHR was 168.26 Hz (male: 135.16 Hz, female: 201.37 Hz), 2.27%, 6.95%, 0.26, post-operative values of these parameters was 162.72 Hz (male: 128.267 Hz, female: 197.18 Hz), 1.71%, 5.36%, 0.20 in OperaVOXTM. There was high intersoftware agreement for F0, jitter, shimmer with intraclass correlation coefficient. Conclusion Our results showed that the short-term variability of acoustic parameters in both MDVP and OperaVOXTM were useful for the objective assessment of voice quality in patients who received laryngeal microsurgery. OperaVOXTM is comparable to MDVP and has high intersoftware reliability with MDVP in measuring the F0, jitter, and shimmer

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

A Multilevel Analysis about the Impact of Patient's Willingness for Discharge on Successful Discharge from Long-term Care Hospitals (퇴원 의지가 요양병원의 성공적 퇴원에 미치는 영향에 대한 다수준 분석)

  • Ghang, Haryeom;Lee, Yeonju
    • Health Policy and Management
    • /
    • v.32 no.4
    • /
    • pp.347-355
    • /
    • 2022
  • Background: Since November 2019, long-term care hospitals have been able to provide patients with discharging programs to support the elderly in the community. This study aimed to identify both patient- and hospital-level factors that affect successful community discharge from long-term care hospitals. Methods: A multilevel logistic regression model was performed using hospitals as a clustering unit. The dependent variable was whether a patient stayed in the community for at least 30 days after discharge from a long-term care hospital. As for the patient-level independent variables, an agreement between a patient and the family about discharge, length of hospital stay, patient category, and residence at discharge were included. The number of beds and the ratio of long-stay patients were selected for the hospital-level factors. The sample size was 1,428 patients enrolled in the discharging program from November 2019 to December 2020. Results: The number of patients who were discharged to the community and stayed at least for 30 days was 532 (37.3%). The intraclass correlation coefficient was 22.9%, indicating that hospital-level factors had a significant impact on successful community discharge. The odds ratio (OR) of successful community discharge increased by 1.842 times when the patients and their families agreed on discharge. The ORs also increased by 3.020 or 2.681 times, respectively when the patients planned to discharge to their own house or their child's house compared to those who didn't have a plan for residence at discharge. The ORs increased by 1.922 or 2.250 times when the hospitals were owned by corporate or private property compared to publicly owned hospitals. The ORs decreased by 0.602 or 0.520 times when the hospital was sized over 400 beds or located in small and medium-sized cities compared to less than 200 bedded hospitals or located in metropolitan cities. Conclusion: The results of the study showed that the patients' and their family's willingness for discharge had a great impact on successful community discharge and the hospital-level factors played a significant role in it. Therefore, it is important to acknowledge and support long-term care hospitals to involve active in the patient discharge planning process.

Analysis of Tissue Equivalent Characteristics of Agar Phantom for Hyperthermia Therapy (온열종양치료 한천 팬텀의 조직등가 특성 분석)

  • Jeong-Geun Park;Kyeong-Hwan Jeong;Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.985-991
    • /
    • 2023
  • A tissue-equivalent phantom is necessary for quality control of hyperthermia therapy. However, since there is no phantom for this purpose, phantoms made from agar are being used in various studies. The tissue-equivalent properties of the agar phantom were confirmed by comparison with the tissue-equivalent material bolus in this study. CT images of the agar phantom and bolus were acquired, and tissue equivalent characteristics were analyzed with image analysis and dose calculation using a computerized radiation therapy planning system. The average pixel value was 96.960±10.999 in bolus, 108.559±8.233 in 3% agar phantom, and 111.844±8.651 in 4% agar phantom. Using the SSD technique, 100 cGy was prescribed at a depth of 1.5 cm and 6 MV X -ray was set to irradiated to 10x10 cm2, and the absorbed dose according to depth was calculated from the central axis of the beam. The intraclass correlation coefficient of dose distribution of bolus, 3% agar phantom, and 4% agar phantom was 0.979 (p<.001, 95%CI .957-.991). The density (g/cm3) at the point where the absorbed dose was calculated was 0.990±0.020 at the bolus, 1.018±0.020 at the 3% agar phantom, and 1.035±0.024 at the 4% agar phantom. In this study, the internal density distribution and uniformity of the agar phantom were confirmed to be appropriate as a tissue equivalent material by analysis of CT images and a computerized radiation therapy planning system.